{"title":"矩阵变换器与一种新的控制方法","authors":"T. Schulte, G. Schroder","doi":"10.1109/EPE.2014.6910717","DOIUrl":null,"url":null,"abstract":"In this paper a new drive control strategy for matrix converters is presented that lowers significantly the harmful common mode voltage. The advanced control method is based on the Direct Torque Control scheme. It is applied exemplarily in this paper by use of a Permanent Magnet Synchronous Machine.","PeriodicalId":6508,"journal":{"name":"2014 16th European Conference on Power Electronics and Applications","volume":"13 1","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Matrix converter with a novel control method\",\"authors\":\"T. Schulte, G. Schroder\",\"doi\":\"10.1109/EPE.2014.6910717\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a new drive control strategy for matrix converters is presented that lowers significantly the harmful common mode voltage. The advanced control method is based on the Direct Torque Control scheme. It is applied exemplarily in this paper by use of a Permanent Magnet Synchronous Machine.\",\"PeriodicalId\":6508,\"journal\":{\"name\":\"2014 16th European Conference on Power Electronics and Applications\",\"volume\":\"13 1\",\"pages\":\"1-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 16th European Conference on Power Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2014.6910717\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 16th European Conference on Power Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2014.6910717","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
In this paper a new drive control strategy for matrix converters is presented that lowers significantly the harmful common mode voltage. The advanced control method is based on the Direct Torque Control scheme. It is applied exemplarily in this paper by use of a Permanent Magnet Synchronous Machine.