{"title":"金属钝化剂浓度对变压器油中铜硫腐蚀的影响","authors":"Zonghua Huang","doi":"10.1109/ICHVE.2012.6357143","DOIUrl":null,"url":null,"abstract":"Insulating oil plays an important role of insulation in transformers. However, copper sulphide deposition on oil-paper insulation can lead to insulation failures in power transformers. In order to research the corrosive properties after adding dibenzyl disulfide (DBDS) and 2, 6-Di-tert-butyl-4-methylphenol (DBPC), and the ability of inhibiting corrosion after adding metal deactivator in transformer oil, a series of thermal aging tests are carried on a certain brand of Nynas and Karamay oil in this paper. First of all, testing the corrosive sulfur compounds by ASTM D1275B method; And Nynas oil test after adding a certain amount of metal deactivator is made at 90 °C to analyze the changing of dissolved gas-in-oil content is analyzed. Experiments and analysis results show that DBDS instead of DBPC is the corrosive sulfur compounds; Metal deactivation agent can effectively prevent the occurrence of sulfur corrosion, but it consumes rapidly with the thermal aging; the oil dissolved gas content significantly changes after adding metal deactivator in oil. All of the above results can be the foundation for a further study on corrosive sulfur and control measure in transformer oil.","PeriodicalId":6375,"journal":{"name":"2012 International Conference on High Voltage Engineering and Application","volume":"19 1","pages":"435-438"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Influence of metal deactivator concentration on copper sulfur corrosion in transformer oil\",\"authors\":\"Zonghua Huang\",\"doi\":\"10.1109/ICHVE.2012.6357143\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Insulating oil plays an important role of insulation in transformers. However, copper sulphide deposition on oil-paper insulation can lead to insulation failures in power transformers. In order to research the corrosive properties after adding dibenzyl disulfide (DBDS) and 2, 6-Di-tert-butyl-4-methylphenol (DBPC), and the ability of inhibiting corrosion after adding metal deactivator in transformer oil, a series of thermal aging tests are carried on a certain brand of Nynas and Karamay oil in this paper. First of all, testing the corrosive sulfur compounds by ASTM D1275B method; And Nynas oil test after adding a certain amount of metal deactivator is made at 90 °C to analyze the changing of dissolved gas-in-oil content is analyzed. Experiments and analysis results show that DBDS instead of DBPC is the corrosive sulfur compounds; Metal deactivation agent can effectively prevent the occurrence of sulfur corrosion, but it consumes rapidly with the thermal aging; the oil dissolved gas content significantly changes after adding metal deactivator in oil. All of the above results can be the foundation for a further study on corrosive sulfur and control measure in transformer oil.\",\"PeriodicalId\":6375,\"journal\":{\"name\":\"2012 International Conference on High Voltage Engineering and Application\",\"volume\":\"19 1\",\"pages\":\"435-438\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2012.6357143\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2012.6357143","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Influence of metal deactivator concentration on copper sulfur corrosion in transformer oil
Insulating oil plays an important role of insulation in transformers. However, copper sulphide deposition on oil-paper insulation can lead to insulation failures in power transformers. In order to research the corrosive properties after adding dibenzyl disulfide (DBDS) and 2, 6-Di-tert-butyl-4-methylphenol (DBPC), and the ability of inhibiting corrosion after adding metal deactivator in transformer oil, a series of thermal aging tests are carried on a certain brand of Nynas and Karamay oil in this paper. First of all, testing the corrosive sulfur compounds by ASTM D1275B method; And Nynas oil test after adding a certain amount of metal deactivator is made at 90 °C to analyze the changing of dissolved gas-in-oil content is analyzed. Experiments and analysis results show that DBDS instead of DBPC is the corrosive sulfur compounds; Metal deactivation agent can effectively prevent the occurrence of sulfur corrosion, but it consumes rapidly with the thermal aging; the oil dissolved gas content significantly changes after adding metal deactivator in oil. All of the above results can be the foundation for a further study on corrosive sulfur and control measure in transformer oil.