气相色谱-串联质谱法(GC-MS/MS)测定海鱼样品中的多氯联苯

Quynh Pham Thi Diem, Mai Pham Thi Ngoc, Anh Hoang Quoc, Thuy Le Minh, Huong Nguyen Thi, Hoa Vu Khanh, H. Do Thi Thu, Xuyen Nguyen Thi, Hung Nguyen Xuan, Binh Chu Dinh, Nam Vu Duc
{"title":"气相色谱-串联质谱法(GC-MS/MS)测定海鱼样品中的多氯联苯","authors":"Quynh Pham Thi Diem, Mai Pham Thi Ngoc, Anh Hoang Quoc, Thuy Le Minh, Huong Nguyen Thi, Hoa Vu Khanh, H. Do Thi Thu, Xuyen Nguyen Thi, Hung Nguyen Xuan, Binh Chu Dinh, Nam Vu Duc","doi":"10.47866/2615-9252/vjfc.4072","DOIUrl":null,"url":null,"abstract":"Polychlorinated biphenyls (PCBs) are a typical group of persistent organic pollutants (POPs), which have been listed under Annex A (Elimination) and Annex C (Unintentional production) of the Stockholm Convention. In this study, a gas chromatography tandem mass spectrometry method was developed and applied to analyze concentrations of 28 PCB congeners in some Vietnamese marine fish samples. PCBs in fish samples were ultrasonically extracted with an acetone/n-hexane (1/1, v/v) mixture. The extracts were cleaned up by using multilayer silica gel columns with dichloromethane/n-hexane (1/1, v/v) as elution solvent. PCBs were separated on a DB-5MS column and quantified by using a triple quadrupole mass spectrometer. The MS detector was operated in positive electron impact ionization (EI) mode and selected reaction monitoring (SRM) mode. Calibration curves of 28 PCBs exhibited good linearity (R2 ≥ 0.9998). Instrument detection limits (IDLs) and method detection limits (MDLs) ranged from 0.08 to 0.023 ng/mL and from 0.07 to 1.84 ng/g, respectively. Recoveries of 28 PCBs native and 7 labeled standards in matrix-spike samples ranged from 62.3 to 88.1% and from 75.5 to 91.9%, satisfying criteria proposed by AOAC (recovery 60-115% for 10-100 ppb levels). The validated method was applied to analyze 10 marine fish samples, showing levels of ∑28PCBs from 17 to 851 (mean 230) ng/g lipid. The sum of 6in-PCBs (PCB-28; -52; -101; -138; -153; -180) based on wet weight (w/w) ranged from 1.24 to 3.15 ng/g, which is lower than the maximum level recommended by The European Union (75 ng/g (w/w). Congeners PCB-126 and PCB-169 were not detected in marine fish samples.","PeriodicalId":12896,"journal":{"name":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of polychlorinated biphenyls in marine fish samples by gas chromatography tandem mass spectrometry (GC-MS/MS)\",\"authors\":\"Quynh Pham Thi Diem, Mai Pham Thi Ngoc, Anh Hoang Quoc, Thuy Le Minh, Huong Nguyen Thi, Hoa Vu Khanh, H. Do Thi Thu, Xuyen Nguyen Thi, Hung Nguyen Xuan, Binh Chu Dinh, Nam Vu Duc\",\"doi\":\"10.47866/2615-9252/vjfc.4072\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Polychlorinated biphenyls (PCBs) are a typical group of persistent organic pollutants (POPs), which have been listed under Annex A (Elimination) and Annex C (Unintentional production) of the Stockholm Convention. In this study, a gas chromatography tandem mass spectrometry method was developed and applied to analyze concentrations of 28 PCB congeners in some Vietnamese marine fish samples. PCBs in fish samples were ultrasonically extracted with an acetone/n-hexane (1/1, v/v) mixture. The extracts were cleaned up by using multilayer silica gel columns with dichloromethane/n-hexane (1/1, v/v) as elution solvent. PCBs were separated on a DB-5MS column and quantified by using a triple quadrupole mass spectrometer. The MS detector was operated in positive electron impact ionization (EI) mode and selected reaction monitoring (SRM) mode. Calibration curves of 28 PCBs exhibited good linearity (R2 ≥ 0.9998). Instrument detection limits (IDLs) and method detection limits (MDLs) ranged from 0.08 to 0.023 ng/mL and from 0.07 to 1.84 ng/g, respectively. Recoveries of 28 PCBs native and 7 labeled standards in matrix-spike samples ranged from 62.3 to 88.1% and from 75.5 to 91.9%, satisfying criteria proposed by AOAC (recovery 60-115% for 10-100 ppb levels). The validated method was applied to analyze 10 marine fish samples, showing levels of ∑28PCBs from 17 to 851 (mean 230) ng/g lipid. The sum of 6in-PCBs (PCB-28; -52; -101; -138; -153; -180) based on wet weight (w/w) ranged from 1.24 to 3.15 ng/g, which is lower than the maximum level recommended by The European Union (75 ng/g (w/w). Congeners PCB-126 and PCB-169 were not detected in marine fish samples.\",\"PeriodicalId\":12896,\"journal\":{\"name\":\"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47866/2615-9252/vjfc.4072\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47866/2615-9252/vjfc.4072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

多氯联苯是一类典型的持久性有机污染物,已列入《斯德哥尔摩公约》附件a(消除)和附件C(无意产生)。本研究建立了气相色谱串联质谱法,并应用于分析越南部分海鱼样品中28种多氯联苯同系物的浓度。用丙酮/正己烷(1/1,v/v)混合物超声提取鱼类样品中的多氯联苯。以二氯甲烷/正己烷(1/1,v/v)为洗脱溶剂,采用多层硅胶柱对萃取物进行净化。采用DB-5MS色谱柱分离多氯联苯,采用三重四极杆质谱仪定量。质谱仪在正电子冲击电离(EI)模式和选择性反应监测(SRM)模式下工作。28种pcb的校准曲线线性良好(R2≥0.9998)。仪器检出限(IDLs)为0.08 ~ 0.023 ng/mL,方法检出限(MDLs)为0.07 ~ 1.84 ng/g。28种多氯联苯的天然标准和7种标记标准在基质峰样中的回收率分别为62.3 ~ 88.1%和75.5 ~ 91.9%,满足AOAC提出的标准(10-100 ppb水平的回收率为60 ~ 115%)。将验证的方法应用于10份海鱼样品的分析,结果显示∑28PCBs含量在17 ~ 851(平均230)ng/g脂质范围内。6 - in- pcb之和(PCB-28;-52;-101;-138;-153;-180),湿重(w/w)范围为1.24 ~ 3.15 ng/g,低于欧盟推荐的最大限值(75 ng/g (w/w))。同系物多氯联苯126和多氯联苯169未在海鱼样本中检测到。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of polychlorinated biphenyls in marine fish samples by gas chromatography tandem mass spectrometry (GC-MS/MS)
Polychlorinated biphenyls (PCBs) are a typical group of persistent organic pollutants (POPs), which have been listed under Annex A (Elimination) and Annex C (Unintentional production) of the Stockholm Convention. In this study, a gas chromatography tandem mass spectrometry method was developed and applied to analyze concentrations of 28 PCB congeners in some Vietnamese marine fish samples. PCBs in fish samples were ultrasonically extracted with an acetone/n-hexane (1/1, v/v) mixture. The extracts were cleaned up by using multilayer silica gel columns with dichloromethane/n-hexane (1/1, v/v) as elution solvent. PCBs were separated on a DB-5MS column and quantified by using a triple quadrupole mass spectrometer. The MS detector was operated in positive electron impact ionization (EI) mode and selected reaction monitoring (SRM) mode. Calibration curves of 28 PCBs exhibited good linearity (R2 ≥ 0.9998). Instrument detection limits (IDLs) and method detection limits (MDLs) ranged from 0.08 to 0.023 ng/mL and from 0.07 to 1.84 ng/g, respectively. Recoveries of 28 PCBs native and 7 labeled standards in matrix-spike samples ranged from 62.3 to 88.1% and from 75.5 to 91.9%, satisfying criteria proposed by AOAC (recovery 60-115% for 10-100 ppb levels). The validated method was applied to analyze 10 marine fish samples, showing levels of ∑28PCBs from 17 to 851 (mean 230) ng/g lipid. The sum of 6in-PCBs (PCB-28; -52; -101; -138; -153; -180) based on wet weight (w/w) ranged from 1.24 to 3.15 ng/g, which is lower than the maximum level recommended by The European Union (75 ng/g (w/w). Congeners PCB-126 and PCB-169 were not detected in marine fish samples.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Producing positive control materials for template in PCR testing to detect botulinum neurotoxin types A and B genes Food safety knowledge and practices of vegetarian food processors in Hanoi in 2022-2023 Research and development of non-enzymatic electrochemical sensors utilizing porous ZnO/graphene electrodes to determine xanthine Study on coffee husk treatment by microorganisms A comprehensive study on reference material of Imidacloprid in tomato matrix
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1