{"title":"从泽尼克多项式出发,将隐形眼镜设计为三阶来补偿眼睛的球差","authors":"O. garcia-lievanos, E. Terán-Bobadilla, Luis A Hernandez-Flores, Leticia Sanchez-Gonzalez","doi":"10.1117/12.2526476","DOIUrl":null,"url":null,"abstract":"To compensate the spherical aberration of the eye using the conic constant of the first surface of a contact lens for different refractive errors. Refractive errors were simulated by modifying only the first curvature of the cornea. For every refractive error was calculating Zernike polynomials using Optics Software for Layout and Optimization (OSLO) EDU edition with and without contact lens. To calculate the conic constant of the contact lens we use the Seidel sums for thin lenses from the longitudinal spherical aberration as it proposes V. Mahajan. The value of Zernike spherical aberration coefficient for the eye with farsightedness (+ 5.00 D) + spherical contact lens was 0.142691 μm. The conic constant value to compensate the spherical aberration was -0.222995 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.004354 μm. The value of Zernike spherical aberration coefficient for the eye with myopia (- 5.00 D) + spherical contact lens was 0.144505 μm. The conic constant value to compensate the spherical aberration was -0.101424 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.072820 μm. The proposed method allows us to design contact lenses that compensate for the spherical aberration of the eye from the Zernike polynomials. Although the design of contact lenses is to third order, we obtain a smaller spherical aberration than the chromatic aberration on the axis without use optimization routine.","PeriodicalId":10843,"journal":{"name":"Current Developments in Lens Design and Optical Engineering XX","volume":"40 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Contact lens design to third order to compensate the spherical aberration of the eye from Zernike polynomials\",\"authors\":\"O. garcia-lievanos, E. Terán-Bobadilla, Luis A Hernandez-Flores, Leticia Sanchez-Gonzalez\",\"doi\":\"10.1117/12.2526476\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To compensate the spherical aberration of the eye using the conic constant of the first surface of a contact lens for different refractive errors. Refractive errors were simulated by modifying only the first curvature of the cornea. For every refractive error was calculating Zernike polynomials using Optics Software for Layout and Optimization (OSLO) EDU edition with and without contact lens. To calculate the conic constant of the contact lens we use the Seidel sums for thin lenses from the longitudinal spherical aberration as it proposes V. Mahajan. The value of Zernike spherical aberration coefficient for the eye with farsightedness (+ 5.00 D) + spherical contact lens was 0.142691 μm. The conic constant value to compensate the spherical aberration was -0.222995 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.004354 μm. The value of Zernike spherical aberration coefficient for the eye with myopia (- 5.00 D) + spherical contact lens was 0.144505 μm. The conic constant value to compensate the spherical aberration was -0.101424 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.072820 μm. The proposed method allows us to design contact lenses that compensate for the spherical aberration of the eye from the Zernike polynomials. Although the design of contact lenses is to third order, we obtain a smaller spherical aberration than the chromatic aberration on the axis without use optimization routine.\",\"PeriodicalId\":10843,\"journal\":{\"name\":\"Current Developments in Lens Design and Optical Engineering XX\",\"volume\":\"40 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Developments in Lens Design and Optical Engineering XX\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2526476\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Developments in Lens Design and Optical Engineering XX","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2526476","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

针对不同的屈光不正,利用隐形眼镜第一表面的圆锥常数来补偿眼睛的球差。仅通过改变角膜的第一曲率来模拟屈光不正。对于每一个屈光不正计算泽尼克多项式使用光学软件布局和优化(奥斯陆)EDU版有和没有隐形眼镜。为了计算隐形眼镜的圆锥常数,我们从纵向球差出发,使用薄透镜的赛德尔和,它提出了V. Mahajan。远视(+ 5.00 D) +球面接触镜眼的泽尼克球差系数为0.142691 μm。补偿球差的圆锥常数为-0.222995,眼+非球面接触镜的泽尼克球差系数为0.004354 μm。近视(- 5.00 D)眼+球面接触镜的泽尼克球差系数为0.144505 μm。补偿球差的圆锥常数为-0.101424,眼+非球面接触镜的泽尼克球差系数为0.072820 μm。提出的方法使我们能够设计出从泽尼克多项式中补偿眼球球差的隐形眼镜。虽然隐形眼镜的设计是三阶的,但在不使用优化程序的情况下,得到的球面像差小于轴上的色差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Contact lens design to third order to compensate the spherical aberration of the eye from Zernike polynomials
To compensate the spherical aberration of the eye using the conic constant of the first surface of a contact lens for different refractive errors. Refractive errors were simulated by modifying only the first curvature of the cornea. For every refractive error was calculating Zernike polynomials using Optics Software for Layout and Optimization (OSLO) EDU edition with and without contact lens. To calculate the conic constant of the contact lens we use the Seidel sums for thin lenses from the longitudinal spherical aberration as it proposes V. Mahajan. The value of Zernike spherical aberration coefficient for the eye with farsightedness (+ 5.00 D) + spherical contact lens was 0.142691 μm. The conic constant value to compensate the spherical aberration was -0.222995 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.004354 μm. The value of Zernike spherical aberration coefficient for the eye with myopia (- 5.00 D) + spherical contact lens was 0.144505 μm. The conic constant value to compensate the spherical aberration was -0.101424 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.072820 μm. The proposed method allows us to design contact lenses that compensate for the spherical aberration of the eye from the Zernike polynomials. Although the design of contact lenses is to third order, we obtain a smaller spherical aberration than the chromatic aberration on the axis without use optimization routine.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A laser pumping double-light-source module with photon-recycling Optical systems for large-aperture phased laser array including diffractive optics Deployment of combined higher order aberrations to extend the depth of focus of lenses Exposure of Restore-L camera optical elements to a simulated orbital radiation environment Application of GPUs in optical design software
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1