M. Kawasaki, Tsuyoshi Inoue, K. Fukuhara, S. Uchiyama
{"title":"气相色谱/质谱法测定食品中氨基甲酸酯和有机氮农药的研究","authors":"M. Kawasaki, Tsuyoshi Inoue, K. Fukuhara, S. Uchiyama","doi":"10.3358/SHOKUEISHI.40.5_382","DOIUrl":null,"url":null,"abstract":"Studies to develop a GC/MS (SIM) method for the determination of 34 pesticides including carbamates and organonitrogen pesticides in foods with solid-phase extraction (SPE) were conducted.Three kinds of SPE columns, a porous diatomaceous earth cartridge column, a diatomite column with a mini C18 cartridge column and a Florisil cartridge column were used successively to clean-up the extract from foods as an alternative to a separatory funnel for liquid-liquid partition. The handling was simpler than the conventional method and gave high recoveries of the pesticides.In GC/MS (SIM), 2 to 4 different fragment ions were selected for each pesticide so that the GC/MS (SIM) identification could be done more accurately for multi-residue analysis of carbamate and organonitrogen pesticides. This simpler method was applicable for 29 pesticides out of 34 with almost the same recoveries and detection limits as the conventional method.","PeriodicalId":17269,"journal":{"name":"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Study on GC/MS (SIM) for Determination of Carbamate and Organonitrogen Pesticides in Foods with Simple Clean-up by SPE Method\",\"authors\":\"M. Kawasaki, Tsuyoshi Inoue, K. Fukuhara, S. Uchiyama\",\"doi\":\"10.3358/SHOKUEISHI.40.5_382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Studies to develop a GC/MS (SIM) method for the determination of 34 pesticides including carbamates and organonitrogen pesticides in foods with solid-phase extraction (SPE) were conducted.Three kinds of SPE columns, a porous diatomaceous earth cartridge column, a diatomite column with a mini C18 cartridge column and a Florisil cartridge column were used successively to clean-up the extract from foods as an alternative to a separatory funnel for liquid-liquid partition. The handling was simpler than the conventional method and gave high recoveries of the pesticides.In GC/MS (SIM), 2 to 4 different fragment ions were selected for each pesticide so that the GC/MS (SIM) identification could be done more accurately for multi-residue analysis of carbamate and organonitrogen pesticides. This simpler method was applicable for 29 pesticides out of 34 with almost the same recoveries and detection limits as the conventional method.\",\"PeriodicalId\":17269,\"journal\":{\"name\":\"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3358/SHOKUEISHI.40.5_382\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3358/SHOKUEISHI.40.5_382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Study on GC/MS (SIM) for Determination of Carbamate and Organonitrogen Pesticides in Foods with Simple Clean-up by SPE Method
Studies to develop a GC/MS (SIM) method for the determination of 34 pesticides including carbamates and organonitrogen pesticides in foods with solid-phase extraction (SPE) were conducted.Three kinds of SPE columns, a porous diatomaceous earth cartridge column, a diatomite column with a mini C18 cartridge column and a Florisil cartridge column were used successively to clean-up the extract from foods as an alternative to a separatory funnel for liquid-liquid partition. The handling was simpler than the conventional method and gave high recoveries of the pesticides.In GC/MS (SIM), 2 to 4 different fragment ions were selected for each pesticide so that the GC/MS (SIM) identification could be done more accurately for multi-residue analysis of carbamate and organonitrogen pesticides. This simpler method was applicable for 29 pesticides out of 34 with almost the same recoveries and detection limits as the conventional method.