Antera 3D®与TcPO2评估皮肤血流的比较

IF 0.9 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Yonago acta medica Pub Date : 2023-02-01 DOI:10.33160/yam.2023.02.016
Kento Ikuta, Kohei Fukuoka, Yoshiko Suyama, Maki Morita, Yuka Kimura, Ryunosuke Umeda, Haruka Kanayama, Makoto Ohga, Makoto Nakagaki, Shunjiro Yagi
{"title":"Antera 3D®与TcPO2评估皮肤血流的比较","authors":"Kento Ikuta,&nbsp;Kohei Fukuoka,&nbsp;Yoshiko Suyama,&nbsp;Maki Morita,&nbsp;Yuka Kimura,&nbsp;Ryunosuke Umeda,&nbsp;Haruka Kanayama,&nbsp;Makoto Ohga,&nbsp;Makoto Nakagaki,&nbsp;Shunjiro Yagi","doi":"10.33160/yam.2023.02.016","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is a need for quick skin blood flow tests that can be performed in the wound healing field. Antera 3D® is a compact scanner using multispectral imaging. It can perform quick assessment of skin conditions. The purpose of the present study was to investigate the ability of the Antera 3D® to assess skin blood flow in comparison with transcutaneous partial pressure of oxygen (TcPO2) measurements.</p><p><strong>Methods: </strong>This study was conducted on 13 patients with a history of lower extremity ulcers. Measurements of hemoglobin average level (hereafter, Hb score) measured by Antera 3D® and TcPO2 measured by a transcutaneous blood gas monitor were obtained at the same sites on the dorsal foot and lower leg. Differences in Hb score and TcPO2 were analyzed by t-test for each measurement site and for the presence of peripheral arterial disease (PAD). The correlation between TcPO2 and Hb score was analyzed by Pearson's correlation coefficient.</p><p><strong>Results: </strong>Twenty-four limbs were tested. Hb score was higher (<i>P</i> < 0.001) and TcPO2 was lower (<i>P</i> = 0.056) in the dorsal foot compared to the lower leg. In the dorsal foot, Hb score was higher (<i>P</i> = 0.023) and TcPO2 was lower (<i>P</i> = 0.046) in patients with PAD compared to those without PAD. A significant negative correlation (<i>r</i> = -0.68; 95% confidence interval -0.85 to -0.38, <i>P</i> < 0.001) between TcPO2 and Hb score was observed in the dorsal foot.</p><p><strong>Conclusion: </strong>The negative correlation between TcPO2 and Hb score may reflect compensatory peripheral vasodilation due to occlusion or stenosis of central arteries. This study showed that Hb score measured by Antera 3D® may be related to skin blood flow.</p>","PeriodicalId":23795,"journal":{"name":"Yonago acta medica","volume":"66 1","pages":"146-152"},"PeriodicalIF":0.9000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9937973/pdf/yam-66-146.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparison of Antera 3D® and TcPO2 for Evaluation of Blood Flow in Skin.\",\"authors\":\"Kento Ikuta,&nbsp;Kohei Fukuoka,&nbsp;Yoshiko Suyama,&nbsp;Maki Morita,&nbsp;Yuka Kimura,&nbsp;Ryunosuke Umeda,&nbsp;Haruka Kanayama,&nbsp;Makoto Ohga,&nbsp;Makoto Nakagaki,&nbsp;Shunjiro Yagi\",\"doi\":\"10.33160/yam.2023.02.016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There is a need for quick skin blood flow tests that can be performed in the wound healing field. Antera 3D® is a compact scanner using multispectral imaging. It can perform quick assessment of skin conditions. The purpose of the present study was to investigate the ability of the Antera 3D® to assess skin blood flow in comparison with transcutaneous partial pressure of oxygen (TcPO2) measurements.</p><p><strong>Methods: </strong>This study was conducted on 13 patients with a history of lower extremity ulcers. Measurements of hemoglobin average level (hereafter, Hb score) measured by Antera 3D® and TcPO2 measured by a transcutaneous blood gas monitor were obtained at the same sites on the dorsal foot and lower leg. Differences in Hb score and TcPO2 were analyzed by t-test for each measurement site and for the presence of peripheral arterial disease (PAD). The correlation between TcPO2 and Hb score was analyzed by Pearson's correlation coefficient.</p><p><strong>Results: </strong>Twenty-four limbs were tested. Hb score was higher (<i>P</i> < 0.001) and TcPO2 was lower (<i>P</i> = 0.056) in the dorsal foot compared to the lower leg. In the dorsal foot, Hb score was higher (<i>P</i> = 0.023) and TcPO2 was lower (<i>P</i> = 0.046) in patients with PAD compared to those without PAD. A significant negative correlation (<i>r</i> = -0.68; 95% confidence interval -0.85 to -0.38, <i>P</i> < 0.001) between TcPO2 and Hb score was observed in the dorsal foot.</p><p><strong>Conclusion: </strong>The negative correlation between TcPO2 and Hb score may reflect compensatory peripheral vasodilation due to occlusion or stenosis of central arteries. This study showed that Hb score measured by Antera 3D® may be related to skin blood flow.</p>\",\"PeriodicalId\":23795,\"journal\":{\"name\":\"Yonago acta medica\",\"volume\":\"66 1\",\"pages\":\"146-152\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9937973/pdf/yam-66-146.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Yonago acta medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.33160/yam.2023.02.016\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Yonago acta medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.33160/yam.2023.02.016","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:在伤口愈合领域,需要一种快速的皮肤血流试验。Antera 3D®是一种使用多光谱成像的紧凑型扫描仪。它可以快速评估皮肤状况。本研究的目的是研究Antera 3D®与经皮氧分压(TcPO2)测量相比评估皮肤血流量的能力。方法:对13例有下肢溃疡病史的患者进行研究。通过Antera 3D®测量血红蛋白平均水平(以下简称Hb评分),通过经皮血气监测仪测量TcPO2,在足背和小腿的相同部位测量。采用t检验分析各测量部位Hb评分和TcPO2的差异以及是否存在外周动脉疾病(PAD)。采用Pearson相关系数分析TcPO2与Hb评分的相关性。结果:共检测24条肢体。与小腿相比,足背Hb评分较高(P < 0.001), TcPO2较低(P = 0.056)。与无PAD患者相比,PAD患者足背Hb评分较高(P = 0.023), TcPO2较低(P = 0.046)。显著负相关(r = -0.68;95%可信区间为-0.85 ~ -0.38,P < 0.001)。结论:TcPO2与Hb评分呈负相关可能反映了中央动脉闭塞或狭窄引起的代偿性外周血管舒张。本研究表明,Antera 3D®测量的Hb评分可能与皮肤血流量有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Antera 3D® and TcPO2 for Evaluation of Blood Flow in Skin.

Background: There is a need for quick skin blood flow tests that can be performed in the wound healing field. Antera 3D® is a compact scanner using multispectral imaging. It can perform quick assessment of skin conditions. The purpose of the present study was to investigate the ability of the Antera 3D® to assess skin blood flow in comparison with transcutaneous partial pressure of oxygen (TcPO2) measurements.

Methods: This study was conducted on 13 patients with a history of lower extremity ulcers. Measurements of hemoglobin average level (hereafter, Hb score) measured by Antera 3D® and TcPO2 measured by a transcutaneous blood gas monitor were obtained at the same sites on the dorsal foot and lower leg. Differences in Hb score and TcPO2 were analyzed by t-test for each measurement site and for the presence of peripheral arterial disease (PAD). The correlation between TcPO2 and Hb score was analyzed by Pearson's correlation coefficient.

Results: Twenty-four limbs were tested. Hb score was higher (P < 0.001) and TcPO2 was lower (P = 0.056) in the dorsal foot compared to the lower leg. In the dorsal foot, Hb score was higher (P = 0.023) and TcPO2 was lower (P = 0.046) in patients with PAD compared to those without PAD. A significant negative correlation (r = -0.68; 95% confidence interval -0.85 to -0.38, P < 0.001) between TcPO2 and Hb score was observed in the dorsal foot.

Conclusion: The negative correlation between TcPO2 and Hb score may reflect compensatory peripheral vasodilation due to occlusion or stenosis of central arteries. This study showed that Hb score measured by Antera 3D® may be related to skin blood flow.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Yonago acta medica
Yonago acta medica MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.60
自引率
0.00%
发文量
36
审稿时长
>12 weeks
期刊介绍: Yonago Acta Medica (YAM) is an electronic journal specializing in medical sciences, published by Tottori University Medical Press, 86 Nishi-cho, Yonago 683-8503, Japan. The subject areas cover the following: molecular/cell biology; biochemistry; basic medicine; clinical medicine; veterinary medicine; clinical nutrition and food sciences; medical engineering; nursing sciences; laboratory medicine; clinical psychology; medical education. Basically, contributors are limited to members of Tottori University and Tottori University Hospital. Researchers outside the above-mentioned university community may also submit papers on the recommendation of a professor, an associate professor, or a junior associate professor at this university community. Articles are classified into four categories: review articles, original articles, patient reports, and short communications.
期刊最新文献
The Influence of Total Fat Mass and Skeletal Muscle Mass Index on the Occurrence of Perioperative Hypothermia in Patients Undergoing Open Gastrectomy. Effectiveness of Online Parent Training for Parents of Adolescents with Developmental Disabilities: A Retrospective Observational Study Comparing Clinical- and Community-Based Online Parent Training. Parents' Expectations of Parent Training programs for Parents of Children with Neurodevelopmental Disorders in Japan. Impact of Lymphocyte/Monocyte Ratio on Outcomes in Patients with Remnant Gastric Cancer After Gastrectomy. Parental Issues and Support Needs in Selective Mutism in Japan: A Quantitative Content Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1