对过度制备的牙科种植床进行光生物调节治疗对扭矩去除和种植体稳定商数的影响:一项在绵羊身上进行的实验研究。

IF 1.1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Minerva dental and oral science Pub Date : 2024-04-01 Epub Date: 2023-06-16 DOI:10.23736/S2724-6329.23.04788-5
Kocher K Xailani, Shehab A Hamad
{"title":"对过度制备的牙科种植床进行光生物调节治疗对扭矩去除和种植体稳定商数的影响:一项在绵羊身上进行的实验研究。","authors":"Kocher K Xailani, Shehab A Hamad","doi":"10.23736/S2724-6329.23.04788-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Primary stability of dental implant is an important prerequisite for achieving osseointegration. This study was conducted to evaluate the effects of photobiomodulation therapy on bone formation-around implants by measuring the implant removal torque and implant stability quotient.</p><p><strong>Methods: </strong>This study was conducted in six adult male sheep. Four implants were placed on each side of the lower border of the mandible. The implant beds were prepared to a size of 10 mm in length and 4.8 mm in width, to receive an implant of 8 mm in length and 4 mm in width. Laser application to the socket was performed just before implant placement, and was immediately administered to the surface of the implant and the peri-implant bone before suturing of the wound. The therapy was continued twice daily for the next seven consecutive days. The animals were sacrificed at 4, 8, and 12 weeks, with two animals per time point. The implant-removal torque was determined with an electronic wrench, and the implant stability quotient (ISQ) was assessed with an Ostell device.</p><p><strong>Results: </strong>The laser treated sides showed significantly higher removal torque and ISQ, at the three-time points (P<0.05). At 4 weeks, the ISQ was 61.44 (±10.4) in the laser group and 48.2 (±16.7) in the control group. At 8 weeks, the ISQ increased to 62.2 (±5.5) in the laser group and 56.1 (±4.3) in the control group. At 12 weeks, the ISQ was 67 (±4.5) in the laser group and 61.875 (±6.3) in the control group. The removal torque at 4 weeks was 218.6 (±62.6) in the laser group and 147.6 (±40.9) in the control group. At 8 weeks, the removal torque increased to 370.5 (±33.3) in the laser group and 250.2 (±25.0) in the control group. At 12 weeks, the removal torque increased to 912.6 (±177.2) in the laser group and 512.1 (±122.6) in the control group.</p><p><strong>Conclusions: </strong>Photobiomodulation enhances bone formation and improves implant stability in implants with overzealously prepared oversized implant beds.</p>","PeriodicalId":18709,"journal":{"name":"Minerva dental and oral science","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of photobiomodulation therapy of overprepared dental implant bed on torque removal and implant stability quotient: an experimental study in sheep.\",\"authors\":\"Kocher K Xailani, Shehab A Hamad\",\"doi\":\"10.23736/S2724-6329.23.04788-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Primary stability of dental implant is an important prerequisite for achieving osseointegration. This study was conducted to evaluate the effects of photobiomodulation therapy on bone formation-around implants by measuring the implant removal torque and implant stability quotient.</p><p><strong>Methods: </strong>This study was conducted in six adult male sheep. Four implants were placed on each side of the lower border of the mandible. The implant beds were prepared to a size of 10 mm in length and 4.8 mm in width, to receive an implant of 8 mm in length and 4 mm in width. Laser application to the socket was performed just before implant placement, and was immediately administered to the surface of the implant and the peri-implant bone before suturing of the wound. The therapy was continued twice daily for the next seven consecutive days. The animals were sacrificed at 4, 8, and 12 weeks, with two animals per time point. The implant-removal torque was determined with an electronic wrench, and the implant stability quotient (ISQ) was assessed with an Ostell device.</p><p><strong>Results: </strong>The laser treated sides showed significantly higher removal torque and ISQ, at the three-time points (P<0.05). At 4 weeks, the ISQ was 61.44 (±10.4) in the laser group and 48.2 (±16.7) in the control group. At 8 weeks, the ISQ increased to 62.2 (±5.5) in the laser group and 56.1 (±4.3) in the control group. At 12 weeks, the ISQ was 67 (±4.5) in the laser group and 61.875 (±6.3) in the control group. The removal torque at 4 weeks was 218.6 (±62.6) in the laser group and 147.6 (±40.9) in the control group. At 8 weeks, the removal torque increased to 370.5 (±33.3) in the laser group and 250.2 (±25.0) in the control group. At 12 weeks, the removal torque increased to 912.6 (±177.2) in the laser group and 512.1 (±122.6) in the control group.</p><p><strong>Conclusions: </strong>Photobiomodulation enhances bone formation and improves implant stability in implants with overzealously prepared oversized implant beds.</p>\",\"PeriodicalId\":18709,\"journal\":{\"name\":\"Minerva dental and oral science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Minerva dental and oral science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23736/S2724-6329.23.04788-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva dental and oral science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S2724-6329.23.04788-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:种植体的初期稳定性是实现骨结合的重要前提。本研究通过测量种植体拔除扭矩和种植体稳定性商数,评估光生物调节疗法对种植体周围骨形成的影响:方法:本研究以六只成年雄性绵羊为对象。在下颌骨下缘两侧各植入四个种植体。种植床的尺寸为长 10 毫米、宽 4.8 毫米,以接受长 8 毫米、宽 4 毫米的种植体。在植入种植体前对种植窝进行激光照射,并在缝合伤口前立即对种植体表面和种植体周围骨质进行激光照射。在接下来的连续七天中,每天持续治疗两次。动物分别在 4 周、8 周和 12 周时处死,每个时间点处死两只动物。用电子扳手测定种植体拔除扭矩,用 Ostell 设备评估种植体稳定性商数(ISQ):结果:在三个时间点上,接受激光治疗的一侧的拔除扭矩和ISQ都明显更高(PC结论:激光治疗的一侧的拔除扭矩和ISQ都明显更高):光生物调节可促进骨形成,提高过度热处理的超大种植床的种植稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of photobiomodulation therapy of overprepared dental implant bed on torque removal and implant stability quotient: an experimental study in sheep.

Background: Primary stability of dental implant is an important prerequisite for achieving osseointegration. This study was conducted to evaluate the effects of photobiomodulation therapy on bone formation-around implants by measuring the implant removal torque and implant stability quotient.

Methods: This study was conducted in six adult male sheep. Four implants were placed on each side of the lower border of the mandible. The implant beds were prepared to a size of 10 mm in length and 4.8 mm in width, to receive an implant of 8 mm in length and 4 mm in width. Laser application to the socket was performed just before implant placement, and was immediately administered to the surface of the implant and the peri-implant bone before suturing of the wound. The therapy was continued twice daily for the next seven consecutive days. The animals were sacrificed at 4, 8, and 12 weeks, with two animals per time point. The implant-removal torque was determined with an electronic wrench, and the implant stability quotient (ISQ) was assessed with an Ostell device.

Results: The laser treated sides showed significantly higher removal torque and ISQ, at the three-time points (P<0.05). At 4 weeks, the ISQ was 61.44 (±10.4) in the laser group and 48.2 (±16.7) in the control group. At 8 weeks, the ISQ increased to 62.2 (±5.5) in the laser group and 56.1 (±4.3) in the control group. At 12 weeks, the ISQ was 67 (±4.5) in the laser group and 61.875 (±6.3) in the control group. The removal torque at 4 weeks was 218.6 (±62.6) in the laser group and 147.6 (±40.9) in the control group. At 8 weeks, the removal torque increased to 370.5 (±33.3) in the laser group and 250.2 (±25.0) in the control group. At 12 weeks, the removal torque increased to 912.6 (±177.2) in the laser group and 512.1 (±122.6) in the control group.

Conclusions: Photobiomodulation enhances bone formation and improves implant stability in implants with overzealously prepared oversized implant beds.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Minerva dental and oral science
Minerva dental and oral science DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.50
自引率
5.00%
发文量
61
期刊最新文献
In-silico immunoinformatic vaccine design for Treponema denticola ergothionase. Virtual reality in specialized dentistry: employing virtual reality for the alleviation of pain and anxiety in hereditary angioedema patients. Medico-legal considerations in immediate loading implantology: risks, responsibilities, and best practices. Restorative and endodontic clinical strategies during COVID-19 (SARS-CoV-2) pandemic: a revision of the literature. A simple method to identify implant sites in totally edentulous arches: a pilot study with thermo-printed templates used with cone beam computed tomography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1