A NaI(Tl) scintillator for in situ environmental studies and laboratory detection measurements of aqueous potassium chloride

Andrew Parker, C. Boxall, M. Joyce, P. Schotanus
{"title":"A NaI(Tl) scintillator for in situ environmental studies and laboratory detection measurements of aqueous potassium chloride","authors":"Andrew Parker, C. Boxall, M. Joyce, P. Schotanus","doi":"10.1109/NSSMIC.2012.6551056","DOIUrl":null,"url":null,"abstract":"The specification, design, and initial measurements of a thallium-doped sodium-iodide well-type scintillator for the principle use in detecting 40K concentrations in open-source potassium chloride aqueous solutions is discussed. The hazards, safety concerns and radwaste generation associated with using open-source radioactive isotopes present significant difficulties and costs to radioanalytical laboratory research. A solution to this is the use of non-hazardous alternatives - which mimic notable fission products (137Cs) - that can be utilised as reliable and safe substitutes. In this paper a scintillator detector designed to detect the active isotope present in potassium chloride, yet remaining portable for in situ measurements at nuclear sites, is described with preliminary results highlighting its effective use.","PeriodicalId":187728,"journal":{"name":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","volume":" 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2012.6551056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The specification, design, and initial measurements of a thallium-doped sodium-iodide well-type scintillator for the principle use in detecting 40K concentrations in open-source potassium chloride aqueous solutions is discussed. The hazards, safety concerns and radwaste generation associated with using open-source radioactive isotopes present significant difficulties and costs to radioanalytical laboratory research. A solution to this is the use of non-hazardous alternatives - which mimic notable fission products (137Cs) - that can be utilised as reliable and safe substitutes. In this paper a scintillator detector designed to detect the active isotope present in potassium chloride, yet remaining portable for in situ measurements at nuclear sites, is described with preliminary results highlighting its effective use.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于现场环境研究和氯化钾水溶液实验室检测测量的NaI(Tl)闪烁体
讨论了一种用于检测开放源代码氯化钾水溶液中40K浓度的掺铊碘化钠井型闪烁体的规格、设计和初步测量。与使用开源放射性同位素有关的危害、安全问题和放射性废物产生给放射性分析实验室研究带来了重大困难和成本。解决这个问题的一个办法是使用无害的替代品——模仿著名的裂变产物(137Cs)——可以作为可靠和安全的替代品使用。本文介绍了一种闪烁体探测器,用于检测氯化钾中存在的活性同位素,但仍可用于核场所的原位测量,并介绍了其有效使用的初步结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of low-resistivity silicon drift detector arrays for soft X-rays Charge pump detector: Optimization with process and device simulation High-Z radiation shields for x-ray free electron laser detectors Properties of a very large volume LaBr3:Ce detector Simulation studies with SiPM arrays and LYSO crystal matrix analyzing a new readout scheme
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1