Application of shunt active power filters in active distribution networks

Mario Primorac, Z. Klaić, Matej Žnidarec, Josip Job
{"title":"Application of shunt active power filters in active distribution networks","authors":"Mario Primorac, Z. Klaić, Matej Žnidarec, Josip Job","doi":"10.1109/ISGT-Europe54678.2022.9960682","DOIUrl":null,"url":null,"abstract":"Constant increase of electricity demand and integrated renewable energy sources in the grid results in harmonic distortions which can impair power quality (PQ). This paper proposes a methodology for the selection of shunt active power filters as a possible solution to these problems and suggests a way to determine the reference current of the filter. Presented analysis results of the installation of filter units at individual points of the test network, which represent real life distribution grid and power quality measurements, show positive effects of reducing the total harmonic distortion (THD).","PeriodicalId":311595,"journal":{"name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-Europe54678.2022.9960682","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Constant increase of electricity demand and integrated renewable energy sources in the grid results in harmonic distortions which can impair power quality (PQ). This paper proposes a methodology for the selection of shunt active power filters as a possible solution to these problems and suggests a way to determine the reference current of the filter. Presented analysis results of the installation of filter units at individual points of the test network, which represent real life distribution grid and power quality measurements, show positive effects of reducing the total harmonic distortion (THD).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
并联型有源电力滤波器在有源配电网中的应用
电力需求的不断增加和可再生能源在电网中的集成导致谐波畸变,从而影响电能质量。本文提出了一种选择并联有源电力滤波器的方法,作为解决这些问题的可能方法,并提出了确定滤波器参考电流的方法。通过对实际配电网和电能质量测量结果的分析,给出了在测试网络各点安装滤波单元的分析结果,表明在降低总谐波失真(THD)方面有积极的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of HVDC Fault Ride-Through and Continuous Reactive Current Support on Transient Stability in Meshed AC/DC Transmission Grids On the role of demand response and key CCHP technologies for increased integration of variable renewable energy into a microgrid Recuperation of railcar braking energy using energy storage at station level Towards Risk Assessment of Smart Grids with Heterogeneous Assets Application of shunt active power filters in active distribution networks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1