Design of the instrument current transformer for high frequency high power applications

A. Makky, H. Abo-Zied, F. N. Abdelbar, P. Mutschler
{"title":"Design of the instrument current transformer for high frequency high power applications","authors":"A. Makky, H. Abo-Zied, F. N. Abdelbar, P. Mutschler","doi":"10.1109/MEPCON.2008.4562343","DOIUrl":null,"url":null,"abstract":"Current transformers fall into a general category known as instrument transformers. The instrument current transformer safely isolates measurement and control circuitry from the high voltage typically present on the circuit being measured. The instrument current transformer can be used as very important part of the closed loop for control circuit in high power high frequency induction heating applications. Design of an instrument current transformers having a high rating of primary current and high rating of frequency is a challenging process. Normally one can get an instrument current transformers having high current or high frequency. This problem ocurs due to the physical configuration of the core. Traditionally, at high frequency shunt resistance can be used to get a signal from the primary current. This method facing many problems. For this work, our approch is to design and implementation of high frequency instrument current transformer, the primary current up to 200 A and 400 KHz. The experimental results which obtained from the presented design shows a good agreement with the theoretical results.","PeriodicalId":236620,"journal":{"name":"2008 12th International Middle-East Power System Conference","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 12th International Middle-East Power System Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEPCON.2008.4562343","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

Current transformers fall into a general category known as instrument transformers. The instrument current transformer safely isolates measurement and control circuitry from the high voltage typically present on the circuit being measured. The instrument current transformer can be used as very important part of the closed loop for control circuit in high power high frequency induction heating applications. Design of an instrument current transformers having a high rating of primary current and high rating of frequency is a challenging process. Normally one can get an instrument current transformers having high current or high frequency. This problem ocurs due to the physical configuration of the core. Traditionally, at high frequency shunt resistance can be used to get a signal from the primary current. This method facing many problems. For this work, our approch is to design and implementation of high frequency instrument current transformer, the primary current up to 200 A and 400 KHz. The experimental results which obtained from the presented design shows a good agreement with the theoretical results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高频大功率仪表电流互感器的设计
电流互感器属于仪表互感器一类。仪表电流互感器安全地将测量和控制电路与通常存在于被测电路上的高电压隔离开来。在大功率高频感应加热应用中,仪表电流互感器可作为控制回路闭环的重要组成部分。高一次电流和高频率互感器的设计是一个具有挑战性的过程。通常人们可以得到一个具有高电流或高频率的仪表电流互感器。这个问题是由于核心的物理配置造成的。传统上,在高频时可以使用分流电阻从一次电流中获得信号。这种方法面临许多问题。对于这项工作,我们的方法是设计和实现高频仪表电流互感器,一次电流高达200a和400khz。实验结果与理论结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Implementing distributed generation to mitigate under-frequency load shedding Generation coordination for transient stability enhancement using particle swarm optimization Modeling and simulation of Photovoltaic/Wind Hybrid Electric Power System Interconnected with electrical utility Space-charge measurement in composite dielectrics Design of the instrument current transformer for high frequency high power applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1