Geoelectrical Investigation of Groundwater Potential at Proposed Staff Quarters of FCE Technical, Gusau, Zamfara State, Nigeria

Hussaini Anas, Usman Defyan Alhasan, M. Muhammad
{"title":"Geoelectrical Investigation of Groundwater Potential at Proposed Staff Quarters of FCE Technical, Gusau, Zamfara State, Nigeria","authors":"Hussaini Anas, Usman Defyan Alhasan, M. Muhammad","doi":"10.57233/ijsgs.v8i4.368","DOIUrl":null,"url":null,"abstract":"Geoelectric investigation was carried out at proposed staff quarters of FCE, Technical Gusau, located along Gusau – Zaria highway, Zamfara State, Nigeria with the aim of delineating the groundwater potentials. The study area lies in the Basement Complex region of Northern Nigeria and it is situated on Latitude 12o819.64”N to 12o08’24.65’’N and longitude 06o43’28.65’’E to 06o43’37.25’’E with an area coverage of 500 m by 500 m. Vertical Electrical Sounding (VES) technique was employed using Schlumberger array pattern. A total of thirty-six (36) VES points were sounded on Six (6) grided profiles(A-F) separated by 100 m apart with inter VES spacing of 100 m, The VES results depict two distinct curve types namely; H-type and A-type. The results also reveal three distinct geoelectric layers: the top layer, weathered/fractured layer and fresh basement. The top layer has resistivity, depth and thickness range of 10.4 – 158.8 Ωm, 0.4 – 3.6 m and 0.4 – 3.6 m respectively. The second layer has ranges of: resistivity, 6.3 – 525.3 Ωm; depth, 1.4 – 20.8 m, and thickness, 1.0 – 20.4 m. The third layer has resistivity values range of 278.6 – 2726.5 Ωm, its depth and thickness are not defined (to infinity). Seven VES stations (A3, A4, B4, C3, E2, F2 and F5) were delineated for groundwater potential having weathered/fractured resistivity varying between 37.4 and 121.1 Ωm. Depths range were found from 7.9 – 20.8 m and thickness varying between 6.6 and 20.4 m. The results of the study implies that the area has a good groundwater potentials.","PeriodicalId":332500,"journal":{"name":"International Journal of Science for Global Sustainability","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Science for Global Sustainability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.57233/ijsgs.v8i4.368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Geoelectric investigation was carried out at proposed staff quarters of FCE, Technical Gusau, located along Gusau – Zaria highway, Zamfara State, Nigeria with the aim of delineating the groundwater potentials. The study area lies in the Basement Complex region of Northern Nigeria and it is situated on Latitude 12o819.64”N to 12o08’24.65’’N and longitude 06o43’28.65’’E to 06o43’37.25’’E with an area coverage of 500 m by 500 m. Vertical Electrical Sounding (VES) technique was employed using Schlumberger array pattern. A total of thirty-six (36) VES points were sounded on Six (6) grided profiles(A-F) separated by 100 m apart with inter VES spacing of 100 m, The VES results depict two distinct curve types namely; H-type and A-type. The results also reveal three distinct geoelectric layers: the top layer, weathered/fractured layer and fresh basement. The top layer has resistivity, depth and thickness range of 10.4 – 158.8 Ωm, 0.4 – 3.6 m and 0.4 – 3.6 m respectively. The second layer has ranges of: resistivity, 6.3 – 525.3 Ωm; depth, 1.4 – 20.8 m, and thickness, 1.0 – 20.4 m. The third layer has resistivity values range of 278.6 – 2726.5 Ωm, its depth and thickness are not defined (to infinity). Seven VES stations (A3, A4, B4, C3, E2, F2 and F5) were delineated for groundwater potential having weathered/fractured resistivity varying between 37.4 and 121.1 Ωm. Depths range were found from 7.9 – 20.8 m and thickness varying between 6.6 and 20.4 m. The results of the study implies that the area has a good groundwater potentials.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
尼日利亚扎姆法拉州Gusau的FCE技术公司拟建员工宿舍地下水潜力地电调查
在尼日利亚扎姆法拉州古苏-扎里亚高速公路沿线拟议的古索技术工程公司工作人员宿舍进行了地电调查,目的是划定地下水潜力。研究区位于尼日利亚北部基底复发区,位于北纬120819.64”~北纬12008’24.65”,东经06o43’28.65”~东经06o43’37.25”,面积500米× 500米。垂直电测深(VES)技术采用斯伦贝谢阵列方向图。在相隔100 m、间隔100 m的6条格网剖面(A- f)上共测深36个测点,测深结果呈现出两种不同的曲线类型:h型和a型。结果还揭示了三种不同的地电层:顶层、风化/破裂层和新鲜基底。顶层电阻率范围为10.4 ~ 158.8 Ωm,深度范围为0.4 ~ 3.6 m,厚度范围为0.4 ~ 3.6 m。第二层电阻率范围为:6.3 ~ 525.3 Ωm;深度,1.4 - 20.8米,厚度,1.0 - 20.4米。第三层电阻率值范围为278.6 ~ 2726.5 Ωm,其深度和厚度未定义(至无穷远)。圈定了7个测点(A3、A4、B4、C3、E2、F2、F5),风化/裂缝电阻率在37.4 ~ 121.1 Ωm之间。深度范围为7.9 - 20.8米,厚度范围为6.6 - 20.4米。研究结果表明,该地区具有良好的地下水潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Cross-Infection and Risk Prevention in Production Environment: A Multi-criteria Decision-making Approach Analysis of Rainfall Characteristics in Kaduna State, Nigeria from 1999 – 2018 Optimization of Bioethanol Production from Sugar Bagasse by Aspergillus flavus Using Box Behnken Design GIS-Based Evaluation of the Spatio-Temporal Impacts of Rainfall and Temperature Variability on Vegetation Cover in Bauchi State, Nigeria Optimization of Biolubricant from Terminalia catappa (Almond) Seed Oil Using CaO Derived from Limestone as Catalyst
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1