Leakage and breakdown mechanisms in Cu damascene with a bilayer-structured /spl alpha/-SiCN//spl alpha/-SiC dielectric barrier

C. Chiang, I-Hsiu Ko, Mao-chieh Chen, Zhen-Cheng Wu, Yung-Cheng Lu, S. Jang, M. Liang
{"title":"Leakage and breakdown mechanisms in Cu damascene with a bilayer-structured /spl alpha/-SiCN//spl alpha/-SiC dielectric barrier","authors":"C. Chiang, I-Hsiu Ko, Mao-chieh Chen, Zhen-Cheng Wu, Yung-Cheng Lu, S. Jang, M. Liang","doi":"10.1109/IITC.2003.1219754","DOIUrl":null,"url":null,"abstract":"This work investigates the leakage and breakdown mechanisms in the Cu damascene structure with a carbon-doped low-k PECVD organosilicate glass (OSG, k=3) as the intermetal dielectric (IMD) and an /spl alpha/-SiCN(k=5)//spl alpha/-SiC(k=4) bilayer-structured dielectric film as the Cu-cap barrier. It is found that the leakage mechanism between Cu lines is dependent on the thickness ratio of the /spl alpha/-SiCN//spl alpha/-SiC bilayer barrier in the Cu damascene structure. In the Cu damascene using an /spl alpha/-SiCN//spl alpha/-SiC bilayer barrier of 40 nm/10 nm or 30 nm/20 nm bilayer thickness, the large leakage current (Frenkel-Poole emission) between Cu lines is attributed to the plenty of interfacial defects, such as cracks, voids, traps or dangling bonds at the /spl alpha/-SiC/OSG interface, which are generated by the larger tensile force of the thicker /spl alpha/-SiC film. On the other hand, the breakdown field and TDDB (time-dependent-dielectric-breakdown) lifetime of the Cu damascene reveal little dependence on the thickness ratio of the /spl alpha/-SiCN//spl alpha/-SiC bilayer barrier, and the observed breakdown of the Cu damascene structure is presumably due to dielectric breakdown of the bulk OSG layer.","PeriodicalId":212619,"journal":{"name":"Proceedings of the IEEE 2003 International Interconnect Technology Conference (Cat. No.03TH8695)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE 2003 International Interconnect Technology Conference (Cat. No.03TH8695)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IITC.2003.1219754","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This work investigates the leakage and breakdown mechanisms in the Cu damascene structure with a carbon-doped low-k PECVD organosilicate glass (OSG, k=3) as the intermetal dielectric (IMD) and an /spl alpha/-SiCN(k=5)//spl alpha/-SiC(k=4) bilayer-structured dielectric film as the Cu-cap barrier. It is found that the leakage mechanism between Cu lines is dependent on the thickness ratio of the /spl alpha/-SiCN//spl alpha/-SiC bilayer barrier in the Cu damascene structure. In the Cu damascene using an /spl alpha/-SiCN//spl alpha/-SiC bilayer barrier of 40 nm/10 nm or 30 nm/20 nm bilayer thickness, the large leakage current (Frenkel-Poole emission) between Cu lines is attributed to the plenty of interfacial defects, such as cracks, voids, traps or dangling bonds at the /spl alpha/-SiC/OSG interface, which are generated by the larger tensile force of the thicker /spl alpha/-SiC film. On the other hand, the breakdown field and TDDB (time-dependent-dielectric-breakdown) lifetime of the Cu damascene reveal little dependence on the thickness ratio of the /spl alpha/-SiCN//spl alpha/-SiC bilayer barrier, and the observed breakdown of the Cu damascene structure is presumably due to dielectric breakdown of the bulk OSG layer.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双层结构/spl α /-SiCN//spl α /-SiC介质阻挡层在Cu damascend中的泄漏击穿机理
本文以掺杂碳的低k PECVD有机硅酸盐玻璃(OSG, k=3)作为金属间介质(IMD), /spl α /-SiCN(k=5)//spl α /-SiC(k=4)双层结构介质膜作为Cu-cap阻挡层,研究了Cu damascene结构中的泄漏和击穿机制。发现Cu线间的泄漏机制取决于Cu damascense结构中/spl α /-SiCN//spl α /-SiC双层势垒的厚度比。在厚度为40 nm/10 nm或30 nm/20 nm的/spl α /-SiCN//spl α /-SiC双层势垒中,Cu线之间的大泄漏电流(Frenkel-Poole发射)是由于/spl α /-SiC/OSG界面上存在大量的界面缺陷,如裂纹、空洞、陷阱或悬垂键,这些缺陷是由较厚的/spl α /-SiC薄膜的较大拉伸力产生的。另一方面,Cu damascene的击穿场和TDDB(随时间介电击穿)寿命与/spl α /-SiCN//spl α /-SiC双层势垒的厚度比关系不大,Cu damascene结构的击穿可能是由于本体OSG层的介电击穿所致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The application of ALD WN/sub x/C/sub y/ as a copper diffusion barrier Low-pressure CMP for reliable porous low-k/Cu integration Mechanism for early failure in Cu dual damascene structure Leakage and breakdown mechanisms in Cu damascene with a bilayer-structured /spl alpha/-SiCN//spl alpha/-SiC dielectric barrier Linewidth-narrowing due to 193 nm resist deformation during etch of spin-on low-k dielectrics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1