Design and Construction of an Installation for Testing Bubble Generators Used for Water Aeration

M. Ştefănescu, N. V. Sima, M. M. Boltinescu, M. Petroșel, M. Prisecaru
{"title":"Design and Construction of an Installation for Testing Bubble Generators Used for Water Aeration","authors":"M. Ştefănescu, N. V. Sima, M. M. Boltinescu, M. Petroșel, M. Prisecaru","doi":"10.38177/AJAST.2020.4407","DOIUrl":null,"url":null,"abstract":"The paper presents an installation comprising four fine bubble generators each with a circular perforated plate with ∅ 0.2 mm orifices. There is a water tank inside the installation in which compressed air is introduced. The installation is designed so as to ensure the monitoring of the following parameters: 1 - The size of the air bubbles; 2 - The appearance of bubble coalescence; 3 - Increasing the dissolved oxygen concentration in water; 4 - The amount of pressure loss that occurs when air passes through the bubble generator; 5 - The efficiency of the aeration process; 6 - Efficacity of the aeration process; 7 - Air consumption; 8 - Electricity consumption; 9 - Air temperature; 10 - Water temperature; 11 - Compressed air pressure; 12 - Hydrostatic load (H).","PeriodicalId":237665,"journal":{"name":"Hydropower eJournal","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hydropower eJournal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.38177/AJAST.2020.4407","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The paper presents an installation comprising four fine bubble generators each with a circular perforated plate with ∅ 0.2 mm orifices. There is a water tank inside the installation in which compressed air is introduced. The installation is designed so as to ensure the monitoring of the following parameters: 1 - The size of the air bubbles; 2 - The appearance of bubble coalescence; 3 - Increasing the dissolved oxygen concentration in water; 4 - The amount of pressure loss that occurs when air passes through the bubble generator; 5 - The efficiency of the aeration process; 6 - Efficacity of the aeration process; 7 - Air consumption; 8 - Electricity consumption; 9 - Air temperature; 10 - Water temperature; 11 - Compressed air pressure; 12 - Hydrostatic load (H).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
水曝气用气泡发生器试验装置的设计与施工
本文提出了一个装置,包括四个精细的气泡发生器,每个发生器都有一个带∅0.2 mm孔的圆形穿孔板。装置内部有一个水箱,可以向水箱中引入压缩空气。安装的设计是为了保证以下参数的监测:1 -气泡的大小;2 -出现气泡合并;3 -提高水中溶解氧浓度;4 -空气通过气泡发生器时产生的压力损失量;5 -曝气过程的效率;6 -曝气过程的效率;7 -空气消耗量;8 -用电量;9 -空气温度;10 -水温;11 -压缩空气压力;12 -静水载荷(H)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Link between Innovation in the Circular Economy Design and Efficiency Improvement in the Renewable Energy Technologies Hydrodynamics of an Earthquake Swarm Interpolation of Rainfall-River Orle Discharge for Developing 1.032 MW of Hydropower in Estako-West, Nigeria Hydro World: Things Starts Happening When You Start Believing Design and Construction of an Installation for Testing Bubble Generators Used for Water Aeration
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1