{"title":"Research on the pressure fluctuation of ceramic filter backwash","authors":"Shaowu Zhang, Jun Zhao, Jiang Han, Zhijun Hu","doi":"10.1109/ICSSEM.2011.6081325","DOIUrl":null,"url":null,"abstract":"In the present study, we analyzed the origin of pressure fluctuation of ceramic filter during recoiling washing process and found that reducing such pressure fluctuation necessitates the use of an accumulator or the structure improvement of distribution valve. By employing the TT-12 type of ceramic filter machine as an example, according to known conditions and through calculation and analysis, we determined the air pressure and accumulator volume and chose the NXQA-16/10-L-A accumulator. By employing the TT-45 type of ceramic filter machine as an example, changing the internal structure of the distribution valve from round to waist, the backwash time was prolonged. With the use of the two kinds of methods, we demonstrated that the pressure fluctuation was reduced to be within 0.02 MPa, which satisfied the requirements for recoiling washing.","PeriodicalId":406311,"journal":{"name":"2011 International Conference on System science, Engineering design and Manufacturing informatization","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on System science, Engineering design and Manufacturing informatization","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSSEM.2011.6081325","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
In the present study, we analyzed the origin of pressure fluctuation of ceramic filter during recoiling washing process and found that reducing such pressure fluctuation necessitates the use of an accumulator or the structure improvement of distribution valve. By employing the TT-12 type of ceramic filter machine as an example, according to known conditions and through calculation and analysis, we determined the air pressure and accumulator volume and chose the NXQA-16/10-L-A accumulator. By employing the TT-45 type of ceramic filter machine as an example, changing the internal structure of the distribution valve from round to waist, the backwash time was prolonged. With the use of the two kinds of methods, we demonstrated that the pressure fluctuation was reduced to be within 0.02 MPa, which satisfied the requirements for recoiling washing.