SAW based mass-loading biosensor for DNA detection

Hualin Cai, Changjian Zhou, Yihan Zhang, Yi Yang, T. Ren, Cangran Guo, Jing Liu
{"title":"SAW based mass-loading biosensor for DNA detection","authors":"Hualin Cai, Changjian Zhou, Yihan Zhang, Yi Yang, T. Ren, Cangran Guo, Jing Liu","doi":"10.1109/EDSSC.2013.6628122","DOIUrl":null,"url":null,"abstract":"In this paper, a Surface Acoustic Wave (SAW) biosensor with gold coated delay area detecting DNA sequences is proposed. By well-designed procedures of device structure and parameters, we manufactured a simple and high-performance SAW on LiNbO3 substrate. The SAW biosensor with gold delay area that is connected to PCB board through bonding wires could be used for the direct measurement and sonic path comparative measurement of S11 parameter by using Network Analyzer. The device works near 65MHz. The loading mass of DNA probe and target DNA sequences are obtained from frequency shift, which is big enough in this work due to an effective biological treatment method. The testing result shows that the SAW sensor has a high sensitivity of 1.2pg/ml/Hz.","PeriodicalId":333267,"journal":{"name":"2013 IEEE International Conference of Electron Devices and Solid-state Circuits","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference of Electron Devices and Solid-state Circuits","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDSSC.2013.6628122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

In this paper, a Surface Acoustic Wave (SAW) biosensor with gold coated delay area detecting DNA sequences is proposed. By well-designed procedures of device structure and parameters, we manufactured a simple and high-performance SAW on LiNbO3 substrate. The SAW biosensor with gold delay area that is connected to PCB board through bonding wires could be used for the direct measurement and sonic path comparative measurement of S11 parameter by using Network Analyzer. The device works near 65MHz. The loading mass of DNA probe and target DNA sequences are obtained from frequency shift, which is big enough in this work due to an effective biological treatment method. The testing result shows that the SAW sensor has a high sensitivity of 1.2pg/ml/Hz.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于SAW的DNA检测质量负载生物传感器
本文提出了一种表面声波(SAW)生物传感器,该传感器具有金包覆延迟区,可检测DNA序列。通过精心设计器件结构和参数,我们在LiNbO3衬底上制造了一个简单、高性能的SAW。带金延时区的SAW生物传感器通过键合线连接到PCB板上,可用于网络分析仪对S11参数的直接测量和声路比对测量。该设备工作在65MHz附近。DNA探针和目标DNA序列的加载质量是通过频移获得的,由于一种有效的生物处理方法,在本工作中获得了足够大的加载质量。测试结果表明,SAW传感器具有1.2pg/ml/Hz的高灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A 116-dB CMOS op amp with repetitive gain boosting and subthreshold operation A novel design of super-capcitor based on black silicon with atomic layer deposition Analysis on the CTLM and LTLM applicability for GaN HEMTs structure alloyed ohmic contact resistance evaluation A PWM controller with table look-up for DC-DC class E buck/boost conversion Failure analysis of output stage due to ESD stress in submicron CMOS technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1