Assessment of technical condition of condensers of TPP steam turbines according to the data of the power equipment parameters monitoring system

M. Sultanov, I. Boldyrev, P. D. Menshikov, Nikolay Chumakov
{"title":"Assessment of technical condition of condensers of TPP steam turbines according to the data of the power equipment parameters monitoring system","authors":"M. Sultanov, I. Boldyrev, P. D. Menshikov, Nikolay Chumakov","doi":"10.1109/REEPE51337.2021.9388084","DOIUrl":null,"url":null,"abstract":"The article presents method of estimating the current technical condition of condensers of steam turbines of TPP by several indicators, the change of which in aggregate indicates the presence of a defect in the condenser stack. Failure of the condensing unit results in forced turbine downtime. In terms of failure frequency, condensing plants are in leading positions, relative to the rest of the heat exchange equipment. The main causes of the condensing plant failures include the untimely replacement of the condenser pipes. The use of this method can allow you to switch from the system of planned preventive repairs to repair according to the current technical condition.","PeriodicalId":272476,"journal":{"name":"2021 3rd International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 3rd International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REEPE51337.2021.9388084","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article presents method of estimating the current technical condition of condensers of steam turbines of TPP by several indicators, the change of which in aggregate indicates the presence of a defect in the condenser stack. Failure of the condensing unit results in forced turbine downtime. In terms of failure frequency, condensing plants are in leading positions, relative to the rest of the heat exchange equipment. The main causes of the condensing plant failures include the untimely replacement of the condenser pipes. The use of this method can allow you to switch from the system of planned preventive repairs to repair according to the current technical condition.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根据动力设备参数监测系统数据对TPP汽轮机凝汽器技术状态进行了评定
本文提出了用几个指标来估计跨太平洋汽轮机冷凝器目前技术状况的方法,这些指标的变化总体上表明冷凝器堆存在缺陷。冷凝机组的故障导致涡轮机被迫停机。就故障频率而言,相对于其他热交换设备,冷凝装置处于领先地位。凝汽装置故障的主要原因包括凝汽器管道的更换不及时。使用这种方法可以使您从计划预防性维修系统切换到根据当前技术条件进行维修。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Artificial Neural Network in the Control Loop of a Wheeled Robot Impacts of COVID-19 on the Electrical Power Dynamics and Environment of Bangladesh Lightning Measurement in Sarawak, Malaysia: First Results Development of Approaches to Assessing the Actual Technical Condition of Steam Turbines Based on Reliability Indicators Energy efficient employment of Used Petroleum Products as fuel based on environmental norms
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1