{"title":"Reducing contamination of particles reflected in turbo molecular pump","authors":"Hiroyuki Kobayashi, K. Maeda, M. Izawa","doi":"10.1109/ASMC.2009.5155990","DOIUrl":null,"url":null,"abstract":"The behavior of particles that are reflected in a turbo molecular pump was investigated by measuring particle trajectories and number of particles that fell on the wafer. Some scattered particles collide with a wafer at a high velocity, which damage fine patterns of the photoresist on a wafer. Particle contamination can be reduced by supplying carrier gas to form down-flow, when etching plasma is not discharged. During plasma discharge, the number of particles that fall on the wafer decreases, because particles are trapped near the plasma-sheath boundary. We found that down-flow particle control reduces particle contamination by 90% through etching including wafer transfer.","PeriodicalId":184890,"journal":{"name":"2008 International Symposium on Semiconductor Manufacturing (ISSM)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International Symposium on Semiconductor Manufacturing (ISSM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASMC.2009.5155990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The behavior of particles that are reflected in a turbo molecular pump was investigated by measuring particle trajectories and number of particles that fell on the wafer. Some scattered particles collide with a wafer at a high velocity, which damage fine patterns of the photoresist on a wafer. Particle contamination can be reduced by supplying carrier gas to form down-flow, when etching plasma is not discharged. During plasma discharge, the number of particles that fall on the wafer decreases, because particles are trapped near the plasma-sheath boundary. We found that down-flow particle control reduces particle contamination by 90% through etching including wafer transfer.