Multi-User ECG Monitoring System based on IEEE Standard 802.15.6

Alessandra Galli, G. Giorgi, C. Narduzzi
{"title":"Multi-User ECG Monitoring System based on IEEE Standard 802.15.6","authors":"Alessandra Galli, G. Giorgi, C. Narduzzi","doi":"10.1109/IWMN.2019.8805046","DOIUrl":null,"url":null,"abstract":"Wearable devices are an enabling technology for pervasive and continuous physiological monitoring of health conditions. In this paper the aim is to provide continuous health monitor for a group of people living in the same place. Monitoring examples range from health conditions of elderly people in a nursing or rest home, to physical conditions of people doing physical activity in a gym or a swimming pool. We consider the implementation of IEEE Standard 802.15.6, focusing on a real time cardiac activity monitoring in a rest home scenario, but a variety of application with similar features can also be considered. We investigate the effect of different parameters, such as the duration of the superframe and its fields, the user priority (UP) of the nodes and packet payload size.Through numerical simulation we analyze network configurations with the aim of providing quality of service (QoS) support to the highest number of nodes. The considered set up is also able to support a sufficiently high number of nodes for the proposed application also in regards of quality of experience (QoE).The CSMA/CA protocol allows to handle mobility with a suitable degree of flexibility, so that monitored subjects need not be restricted in their movement. Multiple collection nodes must be employed when larger areas have to be covered and in this case dealing with mobility becomes more complex, but this analysis is beyond the scope of this paper.","PeriodicalId":272577,"journal":{"name":"2019 IEEE International Symposium on Measurements & Networking (M&N)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Symposium on Measurements & Networking (M&N)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWMN.2019.8805046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Wearable devices are an enabling technology for pervasive and continuous physiological monitoring of health conditions. In this paper the aim is to provide continuous health monitor for a group of people living in the same place. Monitoring examples range from health conditions of elderly people in a nursing or rest home, to physical conditions of people doing physical activity in a gym or a swimming pool. We consider the implementation of IEEE Standard 802.15.6, focusing on a real time cardiac activity monitoring in a rest home scenario, but a variety of application with similar features can also be considered. We investigate the effect of different parameters, such as the duration of the superframe and its fields, the user priority (UP) of the nodes and packet payload size.Through numerical simulation we analyze network configurations with the aim of providing quality of service (QoS) support to the highest number of nodes. The considered set up is also able to support a sufficiently high number of nodes for the proposed application also in regards of quality of experience (QoE).The CSMA/CA protocol allows to handle mobility with a suitable degree of flexibility, so that monitored subjects need not be restricted in their movement. Multiple collection nodes must be employed when larger areas have to be covered and in this case dealing with mobility becomes more complex, but this analysis is beyond the scope of this paper.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于IEEE 802.15.6标准的多用户心电监护系统
可穿戴设备是对健康状况进行普遍和持续的生理监测的一种使能技术。本文的目的是为居住在同一地点的一组人提供连续的健康监测。监测的例子包括养老院或疗养院老年人的健康状况,以及在健身房或游泳池进行体育活动的人的身体状况。我们考虑IEEE标准802.15.6的实现,重点是在休息的家庭场景中实时监测心脏活动,但也可以考虑具有类似功能的各种应用。我们研究了不同参数的影响,如超帧及其字段的持续时间,节点的用户优先级(UP)和数据包有效载荷大小。通过数值模拟,我们分析了网络配置,目的是为最大数量的节点提供服务质量(QoS)支持。考虑的设置还能够在体验质量(QoE)方面为提议的应用程序支持足够多的节点。CSMA/CA协议允许以适当的灵活性处理移动性,因此被监测对象的运动不需要受到限制。当需要覆盖更大的区域时,必须使用多个收集节点,在这种情况下,处理移动性变得更加复杂,但是这种分析超出了本文的范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of a Novel Measurement Technique for Emulating Real Life Environment within a Semi Reverberating Chamber Indoor Location Services through Multi-Source Learning-based Radio Fingerprinting Techniques Passive Peak Voltage Sensor for Multiple Sending Coils Inductive Power Transmission System Evaluation of Machine Learning Algorithms for Anomaly Detection in Industrial Networks A measurement procedure for the optimization of a distributed indoor localization system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1