Active common-mode voltage reduction in a fault-tolerant three-phase inverter

D. Mohammadi, S. Ahmed-Zaid
{"title":"Active common-mode voltage reduction in a fault-tolerant three-phase inverter","authors":"D. Mohammadi, S. Ahmed-Zaid","doi":"10.1109/APEC.2016.7468264","DOIUrl":null,"url":null,"abstract":"A fault-tolerant topology in a three-phase four-leg inverter which is capable of reducing the common-mode voltage (CMV) during the post-fault condition is presented. The CMV during both post-fault and pre-fault is investigated. This paper proposes a topology to reduce the common-mode voltage during pre- and post-fault operation of the inverter by using the healthy switches. The accompanying simulation results verify the common-mode current reduction during the fault period.","PeriodicalId":143091,"journal":{"name":"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2016.7468264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A fault-tolerant topology in a three-phase four-leg inverter which is capable of reducing the common-mode voltage (CMV) during the post-fault condition is presented. The CMV during both post-fault and pre-fault is investigated. This paper proposes a topology to reduce the common-mode voltage during pre- and post-fault operation of the inverter by using the healthy switches. The accompanying simulation results verify the common-mode current reduction during the fault period.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
容错三相逆变器的有源共模电压降低
提出了一种能够降低故障后共模电压的三相四脚逆变器容错拓扑结构。研究了故障后和故障前的CMV。本文提出了一种利用健康开关降低逆变器故障前后共模电压的拓扑结构。仿真结果验证了故障期间共模电流减小的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel model predictive control algorithm to suppress the zero-sequence circulating currents for parallel three-phase voltage source inverters Mode transition control strategy for multiple inverter based distributed generators operating in grid-connected and stand-alone mode Stability analysis and improvement of solid state transformer (SST)-paralleled inverters system using negative impedance feedback control Active common-mode voltage reduction in a fault-tolerant three-phase inverter A sustained increase of input current distortion in active input current shapers to eliminate electrolytic capacitor for designing ac to dc HB-LED drivers for retrofit lamps applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1