ESTIMATION OF REACTIVE POWER EXPORT AND IMPORT CAPABILITY FOR NON-UTILITY GENERATORS

G. J. Nolan, E. B. Khalafalla, E. H. Arnold, D. Winge, B. Swartley
{"title":"ESTIMATION OF REACTIVE POWER EXPORT AND IMPORT CAPABILITY FOR NON-UTILITY GENERATORS","authors":"G. J. Nolan, E. B. Khalafalla, E. H. Arnold, D. Winge, B. Swartley","doi":"10.1109/ICPS.1995.528569","DOIUrl":null,"url":null,"abstract":"Non-utility generators (NUG's) are typically required by their electric power sales agreement to have the capability to supply power to the purchasing utility near unity power factor. With the advent of large combustion turbine generators, many NUG's are simple or combined cycle facilities with generating capacities in excess of 100 MW. Utilities are recognizing that these large NUG facilities can be significant contributors to the reactive power [megavars (MVArs)] flow needed to support system requirements and transmission level grid voltages. NUG's are now being dispatched for MVAr export and import activities to meet utility requirements. The ability of a NUG to export or import MVArs is highly dependent on the actual transmission intertie voltage level. Unless plant-specific studies are performed, this capacity can be difficult to ascertain for the NUG operating and engineering personnel. This paper presents a method, based on system load-flow studies, for estimating the capacity of a NUG to export or import MVArs at a given transmission intertie voltage level. It also explores other key variables which determine the ability of a NUG to export or import VArs. This methodology can be used to aid operating personnel at existing facilities or as a guide during the design of a new facility.","PeriodicalId":138670,"journal":{"name":"Proceedings of 1995 Industrial and Commercial Power Systems Conference","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1995 Industrial and Commercial Power Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.1995.528569","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Non-utility generators (NUG's) are typically required by their electric power sales agreement to have the capability to supply power to the purchasing utility near unity power factor. With the advent of large combustion turbine generators, many NUG's are simple or combined cycle facilities with generating capacities in excess of 100 MW. Utilities are recognizing that these large NUG facilities can be significant contributors to the reactive power [megavars (MVArs)] flow needed to support system requirements and transmission level grid voltages. NUG's are now being dispatched for MVAr export and import activities to meet utility requirements. The ability of a NUG to export or import MVArs is highly dependent on the actual transmission intertie voltage level. Unless plant-specific studies are performed, this capacity can be difficult to ascertain for the NUG operating and engineering personnel. This paper presents a method, based on system load-flow studies, for estimating the capacity of a NUG to export or import MVArs at a given transmission intertie voltage level. It also explores other key variables which determine the ability of a NUG to export or import VArs. This methodology can be used to aid operating personnel at existing facilities or as a guide during the design of a new facility.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非公用事业发电机无功输出和无功输入能力的估计
非公用事业发电机(NUG)通常要求其电力销售协议具有向采购公用事业提供接近单位功率因数的电力的能力。随着大型燃烧涡轮发电机的出现,许多NUG都是发电能力超过100兆瓦的简单或联合循环设施。公用事业公司认识到,这些大型NUG设施可以为支持系统需求和传输级电网电压所需的无功功率(百万千瓦(mvar))流量做出重要贡献。NUG现在被派往MVAr出口和进口活动,以满足公用事业需求。NUG输出或导入mvar的能力高度依赖于实际的传输互连电压水平。除非进行特定工厂的研究,否则对于NUG操作人员和工程人员来说,这种能力很难确定。本文提出了一种基于系统负载流研究的方法,用于估计在给定输电网电压水平下NUG输出或输入mvar的能力。本文还探讨了决定NUG导出或导入var能力的其他关键变量。该方法可用于帮助现有设施的操作人员或作为新设施设计期间的指南。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A new method for both harmonic voltage and harmonic current suppression and power factor correction in industrial power systems Applications of EMTP for transient stability study of an islanded industrial power system Minimizing the effects of voltage disturbances on continuous industrial processes Comparison between different procedures of reliability analysis for emergency and stand-by power systems A comparison between the ANSI/IEEE and the CENELEC/IEC approach to overload protection of insulated power cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1