Experiment Study of 330kV Transmission Line Tower Gaps at 4300m Altitude

Xiuyuan Yao, Shengfu Wang, Liang Tian, Ling Jiang, Yujian Ding
{"title":"Experiment Study of 330kV Transmission Line Tower Gaps at 4300m Altitude","authors":"Xiuyuan Yao, Shengfu Wang, Liang Tian, Ling Jiang, Yujian Ding","doi":"10.1109/CEEPE55110.2022.9783242","DOIUrl":null,"url":null,"abstract":"In order to ensure the reliability of 330kV transmission project in high altitude areas, especially 3000-5000m above sea level (a.s.l). It is necessary to conduct experimental researches on the discharge characteristics of the air gaps of the 330kV tower. In this paper, the power frequency voltage, the switching impulse and lighting impulse voltage discharge tests were carried out at Tibet. Then, the 50% discharge voltage curves of different altitude were obtained. Finally, the clearance distance required for 330kV transmission lines was also recommended. The results provide the design of 330kV transmission line with technical support, and also more data reserved for the study of high-altitude external insulation.","PeriodicalId":118143,"journal":{"name":"2022 5th International Conference on Energy, Electrical and Power Engineering (CEEPE)","volume":"106 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 5th International Conference on Energy, Electrical and Power Engineering (CEEPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEPE55110.2022.9783242","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In order to ensure the reliability of 330kV transmission project in high altitude areas, especially 3000-5000m above sea level (a.s.l). It is necessary to conduct experimental researches on the discharge characteristics of the air gaps of the 330kV tower. In this paper, the power frequency voltage, the switching impulse and lighting impulse voltage discharge tests were carried out at Tibet. Then, the 50% discharge voltage curves of different altitude were obtained. Finally, the clearance distance required for 330kV transmission lines was also recommended. The results provide the design of 330kV transmission line with technical support, and also more data reserved for the study of high-altitude external insulation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
海拔4300m处330kV输电线路塔隙试验研究
为了保证高海拔地区,特别是海拔3000-5000m (a.s.l)地区330kV输电工程的可靠性。有必要对330kV塔气隙的放电特性进行实验研究。本文在西藏进行了工频电压、开关冲击电压和照明冲击电压放电试验。得到了不同海拔高度50%放电电压曲线。最后对330kV输电线路所需的间隙距离进行了推荐。研究结果为330kV输电线路的设计提供了技术支持,也为高海拔外绝缘的研究预留了更多的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Research on Hybrid Configuration of Photovoltaic and Storage Distribution Network Considering the Power Demand of Important Loads Optimal Dispatch of Novel Power System Considering Tail Gas Power Generation and Fluctuations of Tail Gas Source Study on Evolution Path of Shandong Power Grid Based on "Carbon Neutrality" Goal Thermal State Prediction of Transformers Based on ISSA-LSTM Study on Bird Dropping Flashover Prevention Characteristics of AC Line in Areas Above 4000 m
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1