{"title":"Tunable multi-micro-lens system for high lateral resolution endoscopic optical coherence tomography","authors":"K. Aljasem, A. Seifert, H. Zappe","doi":"10.1109/OMEMS.2008.4607820","DOIUrl":null,"url":null,"abstract":"A pneumatically actuated tunable liquid micro-lens is developed for integration in an endoscopic optical coherence tomography (OCT) system allowing dynamic focusing along the scan depth. An evaluation of the optical performance, particularly transverse resolution, is presented and its utility in OCT discussed. A transverse resolution of about 15 mum which does not vary with a scan depth of 9 mm scan depth has been obtained, performance which cannot be obtained with a fixed focal length lens.","PeriodicalId":402931,"journal":{"name":"2008 IEEE/LEOS International Conference on Optical MEMs and Nanophotonics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE/LEOS International Conference on Optical MEMs and Nanophotonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OMEMS.2008.4607820","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A pneumatically actuated tunable liquid micro-lens is developed for integration in an endoscopic optical coherence tomography (OCT) system allowing dynamic focusing along the scan depth. An evaluation of the optical performance, particularly transverse resolution, is presented and its utility in OCT discussed. A transverse resolution of about 15 mum which does not vary with a scan depth of 9 mm scan depth has been obtained, performance which cannot be obtained with a fixed focal length lens.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于高横向分辨率内窥镜光学相干断层成像的可调多微透镜系统
一种气动驱动的可调液体微透镜被开发用于集成在内镜光学相干断层扫描(OCT)系统中,允许沿扫描深度动态聚焦。给出了光学性能的评价,特别是横向分辨率,并讨论了其在OCT中的应用。横向分辨率约为15 μ m,且不随扫描深度(9 mm)的变化而变化,这是固定焦距透镜无法获得的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optical add/drop filter based on dual curved photonic crystal resonator MEMS based dual-axes confocal clinical endoscope for real time in vivo imaging Widely tunable Fabry-Perot optical filter using fixed-fixed beam actuators A varifocal micromirror with pure parabolic surface using bending moment drive Stabilization of temperature characteristics of micromirror for low-voltage driving using thin film torsion bar of tensile poly-Si
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1