{"title":"Digital technique for power transformer fault detection based on positive sequence admittance approach","authors":"M. Eissa, E. Shehab_Eldin, M. E. Masoud, A. S. Abd-Elatif","doi":"10.1109/MEPCON.2008.4562348","DOIUrl":null,"url":null,"abstract":"This paper presents a novel digital technique for transformer protection. The technique uses the accumulated positive sequence admittances at the two sides of the power transformer. The instantaneous measurements of phase voltage and line current signals at the transformer terminals are used to calculate the accumulated positive sequence admittances. A 500/230-kV Y/Y transformer connected to a 230-kV power system is simulated using MATLAB/SIMIULINK tool. The method depends on stand alone decision at the two terminals of power transformer. Results indicate that the proposed technique is stable, reliable, and fast during the discrimination between internal and external faults, magnetizing inrush currents, and switching on internal faults.","PeriodicalId":236620,"journal":{"name":"2008 12th International Middle-East Power System Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 12th International Middle-East Power System Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEPCON.2008.4562348","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

This paper presents a novel digital technique for transformer protection. The technique uses the accumulated positive sequence admittances at the two sides of the power transformer. The instantaneous measurements of phase voltage and line current signals at the transformer terminals are used to calculate the accumulated positive sequence admittances. A 500/230-kV Y/Y transformer connected to a 230-kV power system is simulated using MATLAB/SIMIULINK tool. The method depends on stand alone decision at the two terminals of power transformer. Results indicate that the proposed technique is stable, reliable, and fast during the discrimination between internal and external faults, magnetizing inrush currents, and switching on internal faults.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于正序导纳方法的电力变压器故障检测数字技术
提出了一种新的变压器保护数字技术。该技术利用电力变压器两侧累积的正序导纳。变压器端子处的相位电压和线路电流信号的瞬时测量用于计算累计正序导纳。利用MATLAB/ simulink仿真工具,对连接到230 kv电力系统的500/230 kv Y/Y变压器进行了仿真。该方法依赖于电力变压器两端的独立判定。结果表明,该方法在内外故障识别、励磁涌流和内部故障导通等方面具有稳定、可靠、快速的特点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Implementing distributed generation to mitigate under-frequency load shedding Generation coordination for transient stability enhancement using particle swarm optimization Modeling and simulation of Photovoltaic/Wind Hybrid Electric Power System Interconnected with electrical utility Space-charge measurement in composite dielectrics Design of the instrument current transformer for high frequency high power applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1