CPAP-Applikation bei der Thorakozentese: Pleuralen Druckabfall mindern und Komplikationen verhindern

T. Lesser
{"title":"CPAP-Applikation bei der Thorakozentese: Pleuralen Druckabfall mindern und Komplikationen verhindern","authors":"T. Lesser","doi":"10.1159/000505220","DOIUrl":null,"url":null,"abstract":"Background: Excessive drop of pleural pressure (Ppl) during therapeutic thoracentesis may be related to adverse events and/or to repeated procedures due to incomplete drainage. Objective: This was a pilot study of the impact of the application of continuous positive airway pressure (CPAP) at +5 cm H2O upon the Ppl profile during thoracentesis. Methods: This was a prospective, controlled study of 49 consecutive adults who underwent thoracentesis. Enrollment was via alternation on a one-to-one basis. Pleural manometry was used to compare serial Ppl in patients using CPAP at +5 cm H2O (CPAP group) with Ppl in patients without CPAP (control group). Results: Mean volumes drained were comparable between CPAP and control groups (1,380 vs. 1,396 mL). Patients in the CPAP group had a significantly greater change in volume per centimeter water column pressure (p = 0.0231, 95% confidence interval 6.41-82.61). No patient in the CPAP group had a Ppl less than -20 cm H2O at termination of the procedure, while 8 (33%) control group patients developed a pressure lower than -20. No patient in either group developed re-expansion pulmonary edema. Conclusion: The application of CPAP at +5 cm H2O mitigates the decreases in Ppl caused by thoracentesis via an increase in pleural compliance. The clinical implications of this finding merit study.","PeriodicalId":306175,"journal":{"name":"Karger Kompass Pneumologie","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Karger Kompass Pneumologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000505220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Excessive drop of pleural pressure (Ppl) during therapeutic thoracentesis may be related to adverse events and/or to repeated procedures due to incomplete drainage. Objective: This was a pilot study of the impact of the application of continuous positive airway pressure (CPAP) at +5 cm H2O upon the Ppl profile during thoracentesis. Methods: This was a prospective, controlled study of 49 consecutive adults who underwent thoracentesis. Enrollment was via alternation on a one-to-one basis. Pleural manometry was used to compare serial Ppl in patients using CPAP at +5 cm H2O (CPAP group) with Ppl in patients without CPAP (control group). Results: Mean volumes drained were comparable between CPAP and control groups (1,380 vs. 1,396 mL). Patients in the CPAP group had a significantly greater change in volume per centimeter water column pressure (p = 0.0231, 95% confidence interval 6.41-82.61). No patient in the CPAP group had a Ppl less than -20 cm H2O at termination of the procedure, while 8 (33%) control group patients developed a pressure lower than -20. No patient in either group developed re-expansion pulmonary edema. Conclusion: The application of CPAP at +5 cm H2O mitigates the decreases in Ppl caused by thoracentesis via an increase in pleural compliance. The clinical implications of this finding merit study.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在胸肌应用中有cpap应用:尽量缓解颅内压力,避免并发症
背景:治疗性胸腔穿刺过程中胸膜压(Ppl)的过度下降可能与不良事件和/或由于引流不完全导致的重复手术有关。目的:这是一项在+5 cm H2O下应用持续气道正压通气(CPAP)对胸腔穿刺期间Ppl谱影响的初步研究。方法:这是一项前瞻性对照研究,49名连续接受胸腔穿刺的成年人。注册是在一对一的基础上进行的。采用胸膜测压法比较+5 cm H2O时使用CPAP的患者(CPAP组)与未使用CPAP的患者(对照组)的Ppl序列。结果:CPAP组和对照组的平均排气量相当(1380 mL vs 1396 mL)。CPAP组患者每厘米水柱压力的容积变化更大(p = 0.0231, 95%可信区间为6.41-82.61)。CPAP组无患者在手术结束时Ppl低于-20 cm H2O,而8例(33%)对照组患者血压低于-20。两组患者均未发生再扩张性肺水肿。结论:在+ 5cm H2O下应用CPAP可通过增加胸膜依从性来减轻胸腔穿刺引起的Ppl下降。这一发现的临床意义值得进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Zentrale Schlafapnoe bei Patienten mit Herzinsuffizienz: Physiologische Auswirkungen der periodischen Beatmung Kaleidoskop Malignes Mesotheliom: Die diagnostische Aussagekraft einer Computertomographie kritisch hinterfragen Pneumocampus PharmaNews
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1