Bilateral filter for image derived input function in MR-BrainPET

N. da Silva, M. Gaens, U. Pietrzyk, P. Almeida, H. Herzog
{"title":"Bilateral filter for image derived input function in MR-BrainPET","authors":"N. da Silva, M. Gaens, U. Pietrzyk, P. Almeida, H. Herzog","doi":"10.1109/NSSMIC.2012.6551508","DOIUrl":null,"url":null,"abstract":"In positron emission tomography (PET) a post-filtering step may be used to reduce image noise. For that purpose a moving average filter with a Gaussian shape is frequently used. However, such a filter decreases the spatial resolution and increases the spillover between adjacent structures. These effects become important when dealing with small structures such as the carotid arteries with the aim to derive an image derived input function (IDIF). In this work, a bilateral filter which involves the anatomical information from a segmented magnetic resonance image (MRI) is proposed. To test the filter, dynamic FDG images were simulated with GATE (Geant4 Application for Tomographic Emission) for the BrainPET scanner. To evaluate the filter, the signal to noise ratio (SNR) of the IDIF was calculated. Moreover, three approaches to estimate the IDIF were examined, which were based on: i) the carotid volume of interest (VOl) average, ii) the hottest voxels per plane in carotid VOl and iii) the hottest voxels in the carotid VOl. These were evaluated with the area under the curve (AVe) as well as with partial volume coefficients. The results show that the bilateral filter increases the SNR and reduces the differences between the simulated and estimated IDIF. In conclusion, compared to moving average Gaussian filtering the proposed filter reduces the PVE and increases the SNR.","PeriodicalId":187728,"journal":{"name":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2012.6551508","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In positron emission tomography (PET) a post-filtering step may be used to reduce image noise. For that purpose a moving average filter with a Gaussian shape is frequently used. However, such a filter decreases the spatial resolution and increases the spillover between adjacent structures. These effects become important when dealing with small structures such as the carotid arteries with the aim to derive an image derived input function (IDIF). In this work, a bilateral filter which involves the anatomical information from a segmented magnetic resonance image (MRI) is proposed. To test the filter, dynamic FDG images were simulated with GATE (Geant4 Application for Tomographic Emission) for the BrainPET scanner. To evaluate the filter, the signal to noise ratio (SNR) of the IDIF was calculated. Moreover, three approaches to estimate the IDIF were examined, which were based on: i) the carotid volume of interest (VOl) average, ii) the hottest voxels per plane in carotid VOl and iii) the hottest voxels in the carotid VOl. These were evaluated with the area under the curve (AVe) as well as with partial volume coefficients. The results show that the bilateral filter increases the SNR and reduces the differences between the simulated and estimated IDIF. In conclusion, compared to moving average Gaussian filtering the proposed filter reduces the PVE and increases the SNR.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
mri - brainpet图像衍生输入函数的双边滤波器
在正电子发射断层扫描(PET)中,可采用后滤波步骤来降低图像噪声。为此,经常使用高斯形状的移动平均滤波器。然而,这种滤波器降低了空间分辨率,增加了相邻结构之间的溢出。当处理小结构(如颈动脉)时,这些影响变得重要,目的是获得图像派生输入函数(IDIF)。在这项工作中,提出了一种涉及分割磁共振图像(MRI)解剖信息的双边滤波器。为了测试该滤波器,使用GATE (Geant4 Application for Tomographic Emission)对BrainPET扫描仪的动态FDG图像进行了模拟。为了评价该滤波器,计算了IDIF的信噪比(SNR)。此外,研究了三种估计IDIF的方法,它们基于:i)颈动脉感兴趣体积(VOl)平均值,ii)颈动脉VOl中每个平面的最热体素和iii)颈动脉VOl中最热体素。这些方法用曲线下面积(AVe)和部分体积系数进行评估。结果表明,双边滤波器提高了信噪比,减小了模拟和估计IDIF之间的差异。综上所述,与移动平均高斯滤波相比,该滤波降低了PVE,提高了信噪比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of low-resistivity silicon drift detector arrays for soft X-rays Charge pump detector: Optimization with process and device simulation High-Z radiation shields for x-ray free electron laser detectors Properties of a very large volume LaBr3:Ce detector Simulation studies with SiPM arrays and LYSO crystal matrix analyzing a new readout scheme
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1