{"title":"Fault- Tolerant DC-DC Converter with Zero Interruption Time Using Capacitor Health Prognosis","authors":"P. Sharma K., V. T.","doi":"10.36001/ijphm.2023.v14i2.3545","DOIUrl":null,"url":null,"abstract":"A high-end critical electronic system is expected to have hundreds of electronic subsystems, which rely on the Power Management Unit (PMU) to be energized. Having an efficient PMU is crucial and it requires reliable and well-structured voltage buck converters to translate the supplied voltage levels. The buck converters employed in PMU are expected to be fault tolerant and supply uninterrupted power while serving critical subsystems. Active redundant parallel buck converters employed in PMU to achieve fault tolerance increases overhead in terms of area, cost and power dissipation. In this paper, a DC-DC converter is designed for the PMU by combining two legs of buck converters with an effective output of 3.3 V. A simple yet effective technique is proposed to design a fault-tolerant buck DC-DC converter by bypassing a faulty converter leg. The proposed system utilizes an online signal processing-based method for prognostic fault detection. Ripple content in the voltage of the output Aluminum Electrolytic Capacitor (AEC) is monitored and used as a primary health indicator for the primary buck converter leg. Increase in the output ripple due to degradation is used for the prognosis of primary converter failure. The secondary buck converter leg is activated only upon the confirmed prognosis of a faulty primary converter leg to avoid false triggering. The timely prognosis of primary converter failure and activation of secondary converter facilitates uninterrupted power supply. An experimental setup is built and tested in the laboratory. Experimental results indicate a smooth transition from the primary converter leg to the secondary demonstrating an uninterrupted power supply along with the simplicity and effectiveness of the proposed solution","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36001/ijphm.2023.v14i2.3545","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

A high-end critical electronic system is expected to have hundreds of electronic subsystems, which rely on the Power Management Unit (PMU) to be energized. Having an efficient PMU is crucial and it requires reliable and well-structured voltage buck converters to translate the supplied voltage levels. The buck converters employed in PMU are expected to be fault tolerant and supply uninterrupted power while serving critical subsystems. Active redundant parallel buck converters employed in PMU to achieve fault tolerance increases overhead in terms of area, cost and power dissipation. In this paper, a DC-DC converter is designed for the PMU by combining two legs of buck converters with an effective output of 3.3 V. A simple yet effective technique is proposed to design a fault-tolerant buck DC-DC converter by bypassing a faulty converter leg. The proposed system utilizes an online signal processing-based method for prognostic fault detection. Ripple content in the voltage of the output Aluminum Electrolytic Capacitor (AEC) is monitored and used as a primary health indicator for the primary buck converter leg. Increase in the output ripple due to degradation is used for the prognosis of primary converter failure. The secondary buck converter leg is activated only upon the confirmed prognosis of a faulty primary converter leg to avoid false triggering. The timely prognosis of primary converter failure and activation of secondary converter facilitates uninterrupted power supply. An experimental setup is built and tested in the laboratory. Experimental results indicate a smooth transition from the primary converter leg to the secondary demonstrating an uninterrupted power supply along with the simplicity and effectiveness of the proposed solution
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用电容器健康状况诊断实现零中断时间的容错直流-直流转换器
一个高端关键电子系统预计有数百个电子子系统,这些子系统依靠电源管理单元(PMU)供电。高效的 PMU 至关重要,它需要可靠、结构合理的降压转换器来转换所提供的电压水平。PMU 中采用的降压转换器应具有容错能力,在为关键子系统提供服务的同时,还能不间断地供电。PMU 中采用有源冗余并行降压转换器来实现容错,会增加面积、成本和功率耗散方面的开销。本文为 PMU 设计了一个直流-直流转换器,它由两个降压转换器腿组合而成,有效输出电压为 3.3 V。该系统利用基于在线信号处理的方法进行故障预报检测。输出铝电解电容器 (AEC) 电压中的纹波含量受到监测,并被用作主降压转换器肢的主要健康指标。由于劣化导致的输出纹波增加可用于初级转换器故障的预报。二级降压转换器仅在一级转换器故障预报得到确认后才会启动,以避免误触发。及时预测初级转换器故障并启动次级转换器有助于实现不间断供电。实验室建立并测试了一套实验装置。实验结果表明,从一级变流器到二级变流器的平稳过渡证明了不间断供电以及所提解决方案的简单性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Intentions to move abroad among medical students: a cross-sectional study to investigate determinants and opinions. Analysis of Medical Rehabilitation Needs of 2023 Kahramanmaraş Earthquake Victims: Adıyaman Example. Efficacy of whole body vibration on fascicle length and joint angle in children with hemiplegic cerebral palsy. The change process questionnaire (CPQ): A psychometric validation. Clinical Practice Guidelines on Palliative Sedation Around the World: A Systematic Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1