Role of extrinsic factors on magnetoelastic resonance biosensors sensitivity

IF 2.7 3区 工程技术 Q1 ENGINEERING, MULTIDISCIPLINARY Measurement Science and Technology Pub Date : 2024-01-12 DOI:10.1088/1361-6501/ad1e1d
Luiza Felippi de Lima, Roberta Dutra, Diego González, Rubem Luis Sommer, C A Perottoni, C. Aguzzoli, Mariana Roesch-Ely
{"title":"Role of extrinsic factors on magnetoelastic resonance biosensors sensitivity","authors":"Luiza Felippi de Lima, Roberta Dutra, Diego González, Rubem Luis Sommer, C A Perottoni, C. Aguzzoli, Mariana Roesch-Ely","doi":"10.1088/1361-6501/ad1e1d","DOIUrl":null,"url":null,"abstract":"\n Magnetoelastic resonance devices are attractive for application as biosensors in health-related areas as they allow contactless detection of pathogenic agents with high sensitivity. After functionalization, they offer valuable diagnostic options that promote efficient capture of mass on the sensor surface through biological interactions. Magnetoelastic sensors are also sensitive to external factors such as temperature, magnetic fields, and variations in mass that can arise from processes unrelated to biological interactions, including corrosion and salt crystallization. This article evaluates extrinsic factors that affect the response of magnetoelastic resonance sensors for diagnostic applications. In particular, the influence of heat treatments, operation temperature, applied DC magnetic field bias, and corrosive environment were studied. The control of all these factors is crucial for the design, fabrication, and functionalization of magnetoelastic resonance biosensors and for the development of measuring instrumentation and effective measurement protocols. This work established maximum operating temperature and bias field variations to keep the sensor sensitivity. Heat treatment of the sensors before and after coating improved the signal-to-noise ratio and corrosion resistance. Further improvement in corrosion resistance was provided by cathodic protection, which has been proven beneficial for applications of magnetoelastic resonance sensors in aqueous fluids.","PeriodicalId":18526,"journal":{"name":"Measurement Science and Technology","volume":"15 9","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6501/ad1e1d","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Magnetoelastic resonance devices are attractive for application as biosensors in health-related areas as they allow contactless detection of pathogenic agents with high sensitivity. After functionalization, they offer valuable diagnostic options that promote efficient capture of mass on the sensor surface through biological interactions. Magnetoelastic sensors are also sensitive to external factors such as temperature, magnetic fields, and variations in mass that can arise from processes unrelated to biological interactions, including corrosion and salt crystallization. This article evaluates extrinsic factors that affect the response of magnetoelastic resonance sensors for diagnostic applications. In particular, the influence of heat treatments, operation temperature, applied DC magnetic field bias, and corrosive environment were studied. The control of all these factors is crucial for the design, fabrication, and functionalization of magnetoelastic resonance biosensors and for the development of measuring instrumentation and effective measurement protocols. This work established maximum operating temperature and bias field variations to keep the sensor sensitivity. Heat treatment of the sensors before and after coating improved the signal-to-noise ratio and corrosion resistance. Further improvement in corrosion resistance was provided by cathodic protection, which has been proven beneficial for applications of magnetoelastic resonance sensors in aqueous fluids.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
外在因素对磁弹性共振生物传感器灵敏度的影响
磁弹性共振装置可实现高灵敏度的非接触式病原体检测,因此作为生物传感器应用于健康相关领域非常有吸引力。经过功能化处理后,它们可提供有价值的诊断选择,通过生物相互作用促进传感器表面对质量的有效捕捉。磁弹性传感器对外部因素也很敏感,如温度、磁场以及与生物相互作用无关的过程(包括腐蚀和盐结晶)可能引起的质量变化。本文评估了影响诊断应用磁弹性共振传感器响应的外在因素。特别是研究了热处理、工作温度、应用直流磁场偏置和腐蚀环境的影响。所有这些因素的控制对于磁弹性共振生物传感器的设计、制造和功能化以及测量仪器和有效测量协议的开发至关重要。这项研究确定了最大工作温度和偏置场变化,以保持传感器的灵敏度。涂层前后对传感器进行的热处理提高了信噪比和耐腐蚀性。阴极保护进一步提高了耐腐蚀性,这已被证明有利于磁弹性共振传感器在水性流体中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Measurement Science and Technology
Measurement Science and Technology 工程技术-工程:综合
CiteScore
4.30
自引率
16.70%
发文量
656
审稿时长
4.9 months
期刊介绍: Measurement Science and Technology publishes articles on new measurement techniques and associated instrumentation. Papers that describe experiments must represent an advance in measurement science or measurement technique rather than the application of established experimental technique. Bearing in mind the multidisciplinary nature of the journal, authors must provide an introduction to their work that makes clear the novelty, significance, broader relevance of their work in a measurement context and relevance to the readership of Measurement Science and Technology. All submitted articles should contain consideration of the uncertainty, precision and/or accuracy of the measurements presented. Subject coverage includes the theory, practice and application of measurement in physics, chemistry, engineering and the environmental and life sciences from inception to commercial exploitation. Publications in the journal should emphasize the novelty of reported methods, characterize them and demonstrate their performance using examples or applications.
期刊最新文献
Role of extrinsic factors on magnetoelastic resonance biosensors sensitivity Improved performance of BDS-3 time and frequency transfer based on an epoch differenced model with receiver clock estimation Development of Experimental Device for Inductive Heating of Magnetic Nanoparticles Weakly supervised medical image registration with multi-information guidance A soft sensor model based on an improved semi-supervised stacked autoencoder for just-in-time updating of cement clinker production process data f-CaO
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1