Shivaprasad Chalawadi, Malatesh S Pujar, Rajashekhar F Bhajantri
{"title":"Synthesis of CuO/polyaniline/multiwalled carbon nanotube composites using Macaranga indica leaves extract as hydrogen gas sensor.","authors":"Shivaprasad Chalawadi, Malatesh S Pujar, Rajashekhar F Bhajantri","doi":"10.1116/6.0003282","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, we describe the fabrication of hydrogen gas sensors in the form of nanocomposites containing metal oxides such as copper oxide (CuO), multiwalled carbon nanotubes (MWCNTs), and polyaniline (PANI) using a green synthesis method. We used Macaranga indica (M. indica) leaf extract as a reducing and stabilizing agent to prepare copper oxide nanoparticles (CuONPs). The sample was analyzed using various techniques to determine its physicochemical, morphological, and elemental composition. The XRD data showed that the sample is a CuO/PANI/MWCNT nanocomposite by the best match with the reported data. SEM images revealed a uniform distribution of MWCNTs and spherical CuO nanoparticles of 30-40 nm throughout the CNT network. EDX confirmed that the prepared sample is a pure and inline combination of Cu, O, C, and N. Due to the presence of bioactive elements and PANI, we observed 17% and 25% weight loss for CuO and CuO/PANI/MWCNTs. It was found that this combination of materials can detect H2 gas in concentrations ranging from 110 to 2 ppm at temperatures of 200 and 250 °C. As H2 concentration increased, sensitivity varied from 5% to 20%, but response and recovery times were about 290 and 500 s, respectively, for 40 ppm H2 gas. A logistic function fit to Ra/Rg versus H2 was performed using Y = A2 + (A1 - A2)/(1 + (x/x0)p). The energy bands among the CuO/PANI/MWCNT heterointerfaces were used to demonstrate enhanced H2 gas-sensing properties.</p>","PeriodicalId":9053,"journal":{"name":"Biointerphases","volume":"19 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biointerphases","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1116/6.0003282","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
In this study, we describe the fabrication of hydrogen gas sensors in the form of nanocomposites containing metal oxides such as copper oxide (CuO), multiwalled carbon nanotubes (MWCNTs), and polyaniline (PANI) using a green synthesis method. We used Macaranga indica (M. indica) leaf extract as a reducing and stabilizing agent to prepare copper oxide nanoparticles (CuONPs). The sample was analyzed using various techniques to determine its physicochemical, morphological, and elemental composition. The XRD data showed that the sample is a CuO/PANI/MWCNT nanocomposite by the best match with the reported data. SEM images revealed a uniform distribution of MWCNTs and spherical CuO nanoparticles of 30-40 nm throughout the CNT network. EDX confirmed that the prepared sample is a pure and inline combination of Cu, O, C, and N. Due to the presence of bioactive elements and PANI, we observed 17% and 25% weight loss for CuO and CuO/PANI/MWCNTs. It was found that this combination of materials can detect H2 gas in concentrations ranging from 110 to 2 ppm at temperatures of 200 and 250 °C. As H2 concentration increased, sensitivity varied from 5% to 20%, but response and recovery times were about 290 and 500 s, respectively, for 40 ppm H2 gas. A logistic function fit to Ra/Rg versus H2 was performed using Y = A2 + (A1 - A2)/(1 + (x/x0)p). The energy bands among the CuO/PANI/MWCNT heterointerfaces were used to demonstrate enhanced H2 gas-sensing properties.
期刊介绍:
Biointerphases emphasizes quantitative characterization of biomaterials and biological interfaces. As an interdisciplinary journal, a strong foundation of chemistry, physics, biology, engineering, theory, and/or modelling is incorporated into originated articles, reviews, and opinionated essays. In addition to regular submissions, the journal regularly features In Focus sections, targeted on specific topics and edited by experts in the field. Biointerphases is an international journal with excellence in scientific peer-review. Biointerphases is indexed in PubMed and the Science Citation Index (Clarivate Analytics). Accepted papers appear online immediately after proof processing and are uploaded to key citation sources daily. The journal is based on a mixed subscription and open-access model: Typically, authors can publish without any page charges but if the authors wish to publish open access, they can do so for a modest fee.
Topics include:
bio-surface modification
nano-bio interface
protein-surface interactions
cell-surface interactions
in vivo and in vitro systems
biofilms / biofouling
biosensors / biodiagnostics
bio on a chip
coatings
interface spectroscopy
biotribology / biorheology
molecular recognition
ambient diagnostic methods
interface modelling
adhesion phenomena.