High-resolution computed tomography with scattered X-ray radiation and a single pixel detector

A. Ben-Yehuda, O. Sefi, Y. Klein, H. Schwartz, E. Cohen, R. H. Shukrun, S. Shwartz
{"title":"High-resolution computed tomography with scattered X-ray radiation and a single pixel detector","authors":"A. Ben-Yehuda, O. Sefi, Y. Klein, H. Schwartz, E. Cohen, R. H. Shukrun, S. Shwartz","doi":"10.1038/s44172-024-00184-6","DOIUrl":null,"url":null,"abstract":"X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and other opaque samples. In most commercial X-ray modalities, an image is formed by measuring the X-rays that pass through the object of interest. However, despite the potential of scattered radiation to provide additional information about the object, it is often disregarded due to its inherent tendency to cause blurring. Consequently, conventional imaging modalities do not measure or utilize these valuable data. In contrast, we propose and experimentally demonstrate a high resolution technique for X-ray computed tomography (CT) that measures scattered radiation by exploiting computational ghost imaging (CGI). We show that the resolution of our method can exceed 500 µm, which is approximately an order of magnitude higher than the typical resolution of X-ray imaging modalities based on scattered radiation. Our research reveals a promising technique for incorporating scattered radiation data in CT scans to improve image contrast and resolution while minimizing radiation exposure for patients. The findings of our study suggest that our technique could represent a significant advancement in the fields of medical and industrial imaging, with the potential to enhance the accuracy and safety of diagnostic imaging procedures. X-ray computed tomography is a widely used technique for non-invasively visualizing the interior of the human body. A. Ben Yahuda and colleagues report a technique for incorporating scattered radiation data in Computed Tomography scans to improve image resolution and minimize radiation exposure for patients.","PeriodicalId":72644,"journal":{"name":"Communications engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.nature.com/articles/s44172-024-00184-6.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Communications engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.nature.com/articles/s44172-024-00184-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and other opaque samples. In most commercial X-ray modalities, an image is formed by measuring the X-rays that pass through the object of interest. However, despite the potential of scattered radiation to provide additional information about the object, it is often disregarded due to its inherent tendency to cause blurring. Consequently, conventional imaging modalities do not measure or utilize these valuable data. In contrast, we propose and experimentally demonstrate a high resolution technique for X-ray computed tomography (CT) that measures scattered radiation by exploiting computational ghost imaging (CGI). We show that the resolution of our method can exceed 500 µm, which is approximately an order of magnitude higher than the typical resolution of X-ray imaging modalities based on scattered radiation. Our research reveals a promising technique for incorporating scattered radiation data in CT scans to improve image contrast and resolution while minimizing radiation exposure for patients. The findings of our study suggest that our technique could represent a significant advancement in the fields of medical and industrial imaging, with the potential to enhance the accuracy and safety of diagnostic imaging procedures. X-ray computed tomography is a widely used technique for non-invasively visualizing the interior of the human body. A. Ben Yahuda and colleagues report a technique for incorporating scattered radiation data in Computed Tomography scans to improve image resolution and minimize radiation exposure for patients.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用散射 X 射线辐射和单像素探测器进行高分辨率计算机断层扫描
X 射线成像是对人体内部和其他不透明样本进行非侵入式可视化的一种流行技术。在大多数商用 X 射线模式中,图像是通过测量穿过相关物体的 X 射线形成的。然而,尽管散射辐射可能提供有关物体的额外信息,但由于其固有的导致模糊的倾向,往往被忽视。因此,传统的成像模式无法测量或利用这些宝贵的数据。与此相反,我们提出并通过实验演示了一种高分辨率的 X 射线计算机断层扫描(CT)技术,该技术通过利用计算鬼影成像(CGI)来测量散射辐射。我们的研究表明,该方法的分辨率可超过 500 微米,比基于散射辐射的 X 射线成像模式的典型分辨率高出约一个数量级。我们的研究揭示了一种将散射辐射数据纳入 CT 扫描的前景广阔的技术,它可以提高图像对比度和分辨率,同时最大限度地减少对患者的辐射照射。我们的研究结果表明,我们的技术代表了医疗和工业成像领域的一大进步,有可能提高成像诊断程序的准确性和安全性。X 射线计算机断层扫描是一种广泛应用的非侵入性人体内部成像技术。A. Ben Yahuda 及其同事报告了一种将散射辐射数据纳入计算机断层扫描的技术,以提高图像分辨率并最大限度地减少对患者的辐射照射。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A platform-agnostic deep reinforcement learning framework for effective Sim2Real transfer towards autonomous driving Cryogenic quantum computer control signal generation using high-electron-mobility transistors A semi-transparent thermoelectric glazing nanogenerator with aluminium doped zinc oxide and copper iodide thin films Towards a general computed tomography image segmentation model for anatomical structures and lesions 5 G new radio fiber-wireless converged systems by injection locking multi-optical carrier into directly-modulated lasers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1