Comparative analysis of early postoperative results of transcatheter aortic valve implantation and surgical aortic valve replacement with a biological prosthesis.
{"title":"Comparative analysis of early postoperative results of transcatheter aortic valve implantation and surgical aortic valve replacement with a biological prosthesis.","authors":"Mykhailo Todurov, Oleh Zelenchuk, Mykola Stan, Andrii Khokhlov, Serhii Sudakevych, Nataliia Ponych, Stepan Marunyak","doi":"10.36740/Merkur202401102","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>. Aim: The choice of aortic valve stenosis correction method is determined by a number of clinical and technical parameters. The task was to compare early postoperative outcomes in patients after correction of aortic valve stenosis using TAVI and surgical aortic valve replacement with a biological prosthesis.</p><p><strong>Patients and methods: </strong>Materials and Methods: This retrospective study analyzed the medical records of adult patients (18 years of age and older) who had transcatheter aortic valve implantation or surgical aortic valve replacement with a biological prosthesis at the State Institution \"Heart Institute of the Ministry of Health\" in the period from 2018 to 2022.</p><p><strong>Results: </strong>Results: In 47 (47.5%) cases, TAVI was performed and in 52 (52.5%) cases, SAVR with a biological prosthesis was performed. Patients who underwent TAVI were significantly older (p=0.002) and had a higher EuroSCORE II operative risk score (p<0.001). In patients with TAVI, larger diameter aortic valve prostheses were significantly more often used compared with the SAVR group with biological prosthesis (27.5±2.74 vs. 22.5±1.84, p<0.001). The early postoperative period in patients with TAVI was characterized by an 11.4% (p=0.046) and 15.4% (p=0.006). The length of stay in the ICU (p=0.024), as well as the duration of hospitalization in general (p=0.005), was also significantly lower in patients with TAVI compared with patients with biological prosthesis SAVR.</p><p><strong>Conclusion: </strong>Conclusions: Despite the higher surgical risk of surgery according to EuroSCORE II, TAVI was characterized by a lower incidence of postoperative complications, with shorter duration of stay in ICU and hospitalization in general in comparison with patients undergoing SAVR with a biological prosthesis.</p>","PeriodicalId":39518,"journal":{"name":"Polski Merkuriusz Lekarski","volume":"52 1","pages":"10-16"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polski Merkuriusz Lekarski","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36740/Merkur202401102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: . Aim: The choice of aortic valve stenosis correction method is determined by a number of clinical and technical parameters. The task was to compare early postoperative outcomes in patients after correction of aortic valve stenosis using TAVI and surgical aortic valve replacement with a biological prosthesis.
Patients and methods: Materials and Methods: This retrospective study analyzed the medical records of adult patients (18 years of age and older) who had transcatheter aortic valve implantation or surgical aortic valve replacement with a biological prosthesis at the State Institution "Heart Institute of the Ministry of Health" in the period from 2018 to 2022.
Results: Results: In 47 (47.5%) cases, TAVI was performed and in 52 (52.5%) cases, SAVR with a biological prosthesis was performed. Patients who underwent TAVI were significantly older (p=0.002) and had a higher EuroSCORE II operative risk score (p<0.001). In patients with TAVI, larger diameter aortic valve prostheses were significantly more often used compared with the SAVR group with biological prosthesis (27.5±2.74 vs. 22.5±1.84, p<0.001). The early postoperative period in patients with TAVI was characterized by an 11.4% (p=0.046) and 15.4% (p=0.006). The length of stay in the ICU (p=0.024), as well as the duration of hospitalization in general (p=0.005), was also significantly lower in patients with TAVI compared with patients with biological prosthesis SAVR.
Conclusion: Conclusions: Despite the higher surgical risk of surgery according to EuroSCORE II, TAVI was characterized by a lower incidence of postoperative complications, with shorter duration of stay in ICU and hospitalization in general in comparison with patients undergoing SAVR with a biological prosthesis.