Results of the 2023 ISBI challenge to reduce GABA-edited MRS acquisition time

IF 2 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Magnetic Resonance Materials in Physics, Biology and Medicine Pub Date : 2024-04-13 DOI:10.1007/s10334-024-01156-9
Rodrigo Pommot Berto, Hanna Bugler, Gabriel Dias, Mateus Oliveira, Lucas Ueda, Sergio Dertkigil, Paula D. P. Costa, Leticia Rittner, Julian P. Merkofer, Dennis M. J. van de Sande, Sina Amirrajab, Gerhard S. Drenthen, Mitko Veta, Jacobus F. A. Jansen, Marcel Breeuwer, Ruud J. G. van Sloun, Abdul Qayyum, Cristobal Rodero, Steven Niederer, Roberto Souza, Ashley D. Harris
{"title":"Results of the 2023 ISBI challenge to reduce GABA-edited MRS acquisition time","authors":"Rodrigo Pommot Berto, Hanna Bugler, Gabriel Dias, Mateus Oliveira, Lucas Ueda, Sergio Dertkigil, Paula D. P. Costa, Leticia Rittner, Julian P. Merkofer, Dennis M. J. van de Sande, Sina Amirrajab, Gerhard S. Drenthen, Mitko Veta, Jacobus F. A. Jansen, Marcel Breeuwer, Ruud J. G. van Sloun, Abdul Qayyum, Cristobal Rodero, Steven Niederer, Roberto Souza, Ashley D. Harris","doi":"10.1007/s10334-024-01156-9","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>Use a conference challenge format to compare machine learning-based gamma-aminobutyric acid (GABA)-edited magnetic resonance spectroscopy (MRS) reconstruction models using one-quarter of the transients typically acquired during a complete scan.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>There were three tracks: Track 1: simulated data, Track 2: identical acquisition parameters with in vivo data, and Track 3: different acquisition parameters with in vivo data. The mean squared error, signal-to-noise ratio, linewidth, and a proposed shape score metric were used to quantify model performance. Challenge organizers provided open access to a baseline model, simulated noise-free data, guides for adding synthetic noise, and in vivo data.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>Three submissions were compared. A covariance matrix convolutional neural network model was most successful for Track 1. A vision transformer model operating on a spectrogram data representation was most successful for Tracks 2 and 3. Deep learning (DL) reconstructions with 80 transients achieved equivalent or better SNR, linewidth and fit error compared to conventional 320 transient reconstructions. However, some DL models optimized linewidth and SNR without actually improving overall spectral quality, indicating a need for more robust metrics.</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>DL-based reconstruction pipelines have the promise to reduce the number of transients required for GABA-edited MRS.</p>","PeriodicalId":18067,"journal":{"name":"Magnetic Resonance Materials in Physics, Biology and Medicine","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance Materials in Physics, Biology and Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10334-024-01156-9","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Use a conference challenge format to compare machine learning-based gamma-aminobutyric acid (GABA)-edited magnetic resonance spectroscopy (MRS) reconstruction models using one-quarter of the transients typically acquired during a complete scan.

Methods

There were three tracks: Track 1: simulated data, Track 2: identical acquisition parameters with in vivo data, and Track 3: different acquisition parameters with in vivo data. The mean squared error, signal-to-noise ratio, linewidth, and a proposed shape score metric were used to quantify model performance. Challenge organizers provided open access to a baseline model, simulated noise-free data, guides for adding synthetic noise, and in vivo data.

Results

Three submissions were compared. A covariance matrix convolutional neural network model was most successful for Track 1. A vision transformer model operating on a spectrogram data representation was most successful for Tracks 2 and 3. Deep learning (DL) reconstructions with 80 transients achieved equivalent or better SNR, linewidth and fit error compared to conventional 320 transient reconstructions. However, some DL models optimized linewidth and SNR without actually improving overall spectral quality, indicating a need for more robust metrics.

Conclusion

DL-based reconstruction pipelines have the promise to reduce the number of transients required for GABA-edited MRS.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
减少 GABA 编辑 MRS 采集时间的 2023 ISBI 挑战赛结果
目的采用会议挑战赛的形式,使用完整扫描过程中通常获取的四分之一瞬时数据,比较基于机器学习的γ-氨基丁酸(GABA)编辑磁共振波谱(MRS)重建模型:第 1 轨:模拟数据;第 2 轨:相同采集参数与体内数据;第 3 轨:不同采集参数与体内数据。使用均方误差、信噪比、线宽和提议的形状评分指标来量化模型性能。挑战赛组织者提供了基线模型、模拟无噪声数据、添加合成噪声指南和体内数据的开放访问权限。第 1 赛道的协方差矩阵卷积神经网络模型最为成功。在频谱图数据表示上运行的视觉转换器模型在轨道 2 和轨道 3 上最为成功。与传统的 320 个瞬态重构相比,使用 80 个瞬态的深度学习(DL)重构在信噪比、线宽和拟合误差方面取得了相同或更好的效果。结论基于深度学习的重建管道有望减少 GABA 编辑 MRS 所需的瞬态数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
58
审稿时长
>12 weeks
期刊介绍: MAGMA is a multidisciplinary international journal devoted to the publication of articles on all aspects of magnetic resonance techniques and their applications in medicine and biology. MAGMA currently publishes research papers, reviews, letters to the editor, and commentaries, six times a year. The subject areas covered by MAGMA include: advances in materials, hardware and software in magnetic resonance technology, new developments and results in research and practical applications of magnetic resonance imaging and spectroscopy related to biology and medicine, study of animal models and intact cells using magnetic resonance, reports of clinical trials on humans and clinical validation of magnetic resonance protocols.
期刊最新文献
Accelerating multi-coil MR image reconstruction using weak supervision. Real-time automated quality control for quantitative MRI. Compressed SVD-based L + S model to reconstruct undersampled dynamic MRI data using parallel architecture. Impact of truncating diffusion MRI scans on diffusional kurtosis imaging. Diffusion weighted imaging combining respiratory triggering and navigator echo tracking in the upper abdomen.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1