The impact of electric field strength on the accuracy of boron dopant quantification in silicon using atom probe tomography

IF 2.1 3区 工程技术 Q2 MICROSCOPY Ultramicroscopy Pub Date : 2024-08-21 DOI:10.1016/j.ultramic.2024.114034
Bavley Guerguis , Ramya Cuduvally , Richard J.H. Morris , Gabriel Arcuri , Brian Langelier , Nabil Bassim
{"title":"The impact of electric field strength on the accuracy of boron dopant quantification in silicon using atom probe tomography","authors":"Bavley Guerguis ,&nbsp;Ramya Cuduvally ,&nbsp;Richard J.H. Morris ,&nbsp;Gabriel Arcuri ,&nbsp;Brian Langelier ,&nbsp;Nabil Bassim","doi":"10.1016/j.ultramic.2024.114034","DOIUrl":null,"url":null,"abstract":"<div><p>This study investigates the impact of the surface electric field on the quantification accuracy of boron (B) implanted silicon (Si) using atom probe tomography (APT). The Si Charge-State Ratio (CSR(Si) = Si<sup>2+</sup>/Si<sup>+</sup>) was used as an indirect measure of the average apex electric field during analysis. For a range of electric fields, the accuracy of the total implanted dose and the depth profile shape determined by APT was evaluated against the National Institute of Standards and Technology Standard Reference Material 2137. The radial (non-)uniformity of the detected B was also examined. At a higher surface electric field (i.e., a greater CSR(Si)), the determined B dose converges on the certified dose. Additionally, the depth profile shape tends towards that derived by secondary ion mass spectrometry. This improvement coincides with a more uniform radial B distribution, evidenced by desorption maps. In contrast, for lower surface electric fields (i.e., a lower CSR(Si)), the B dose is significantly underestimated, and the depth profile is artificially stretched. The desorption maps also indicate a highly inhomogeneous B emission localized around the center of the detector, which is believed to be an artifact of B surface migration on the tip of the sample. For the purposes of routine investigations of semiconductor devices using APT, these results illustrate the potential origin of quantification artifacts and their severity at different operating conditions, thus providing pathways towards best practices for accurate and repeatable measurements.</p></div>","PeriodicalId":23439,"journal":{"name":"Ultramicroscopy","volume":"266 ","pages":"Article 114034"},"PeriodicalIF":2.1000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultramicroscopy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S030439912400113X","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MICROSCOPY","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigates the impact of the surface electric field on the quantification accuracy of boron (B) implanted silicon (Si) using atom probe tomography (APT). The Si Charge-State Ratio (CSR(Si) = Si2+/Si+) was used as an indirect measure of the average apex electric field during analysis. For a range of electric fields, the accuracy of the total implanted dose and the depth profile shape determined by APT was evaluated against the National Institute of Standards and Technology Standard Reference Material 2137. The radial (non-)uniformity of the detected B was also examined. At a higher surface electric field (i.e., a greater CSR(Si)), the determined B dose converges on the certified dose. Additionally, the depth profile shape tends towards that derived by secondary ion mass spectrometry. This improvement coincides with a more uniform radial B distribution, evidenced by desorption maps. In contrast, for lower surface electric fields (i.e., a lower CSR(Si)), the B dose is significantly underestimated, and the depth profile is artificially stretched. The desorption maps also indicate a highly inhomogeneous B emission localized around the center of the detector, which is believed to be an artifact of B surface migration on the tip of the sample. For the purposes of routine investigations of semiconductor devices using APT, these results illustrate the potential origin of quantification artifacts and their severity at different operating conditions, thus providing pathways towards best practices for accurate and repeatable measurements.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电场强度对利用原子探针层析成像技术量化硅中硼掺杂物精度的影响
本研究利用原子探针断层扫描(APT)技术研究了表面电场对硼(B)植入硅(Si)量化精度的影响。在分析过程中,硅电荷态比(CSR(Si) = Si2+/Si+)被用来间接测量平均顶点电场。对于一定范围的电场,通过 APT 确定的总植入剂量和深度剖面形状的准确性与美国国家标准与技术研究院标准参考材料 2137 进行了对比评估。此外,还检测了检测到的 B 的径向(非)均匀性。在较高的表面电场(即较大的 CSR(Si))下,测定的 B 剂量与认证剂量趋同。此外,深度剖面的形状也趋向于二次离子质谱法得出的形状。这一改进与解吸图显示的更均匀的辐射 B 分布相吻合。相反,对于较低的表面电场(即较低的 CSR(Si)),B 剂量被明显低估,深度剖面被人为拉伸。解吸图还显示,探测器中心周围的 B 发射极不均匀,据信这是 B 在样品顶端表面迁移的假象。就使用 APT 对半导体器件进行常规研究而言,这些结果说明了量化伪影的潜在来源及其在不同操作条件下的严重程度,从而为实现准确、可重复测量的最佳实践提供了途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ultramicroscopy
Ultramicroscopy 工程技术-显微镜技术
CiteScore
4.60
自引率
13.60%
发文量
117
审稿时长
5.3 months
期刊介绍: Ultramicroscopy is an established journal that provides a forum for the publication of original research papers, invited reviews and rapid communications. The scope of Ultramicroscopy is to describe advances in instrumentation, methods and theory related to all modes of microscopical imaging, diffraction and spectroscopy in the life and physical sciences.
期刊最新文献
Corrigendum to "Structure-preserving Gaussian denoising of FIB-SEM volumes" [Ultramicroscopy Volume 246, 113674]. Toward quantitative thermoelectric characterization of (nano)materials by in-situ transmission electron microscopy New experimental methodology for determining the second crossover energy in insulators under stationary e-irradiation in a SEM Beyond the random phase approximation (RPA): First principles calculation of the valence EELS spectrum for KBr including local field, quasiparticle, excitonic and spin orbit coupling effects A high-performance reconstruction method for partially coherent ptychography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1