Effects of a soft back exoskeleton on lower lumbar spine loads during manual materials handling: a musculoskeletal modelling study.

IF 1.7 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS Computer Methods in Biomechanics and Biomedical Engineering Pub Date : 2024-11-04 DOI:10.1080/10255842.2024.2422925
Arthur Favennec, Florent Moissenet, Julien Frère, Guillaume Mornieux
{"title":"Effects of a soft back exoskeleton on lower lumbar spine loads during manual materials handling: a musculoskeletal modelling study.","authors":"Arthur Favennec, Florent Moissenet, Julien Frère, Guillaume Mornieux","doi":"10.1080/10255842.2024.2422925","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to append a passive soft back exoskeleton to a validated musculoskeletal model and assess its effectiveness in reducing lumbar loads. Fifteen participants lifted a box, with and without wearing a CORFOR<sup>®</sup> exoskeleton. A full body OpenSim model was used to estimate lumbar joint moments and reaction forces, as well as low back muscles forces. Wearing the exoskeleton reduced the peak flexion moment, muscles forces, as well as peak compressive and shear forces. This musculoskeletal modelling study shows that wearing the exoskeleton may reduce lumbar spine loads and may contribute to prevent low back disorders.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2024.2422925","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to append a passive soft back exoskeleton to a validated musculoskeletal model and assess its effectiveness in reducing lumbar loads. Fifteen participants lifted a box, with and without wearing a CORFOR® exoskeleton. A full body OpenSim model was used to estimate lumbar joint moments and reaction forces, as well as low back muscles forces. Wearing the exoskeleton reduced the peak flexion moment, muscles forces, as well as peak compressive and shear forces. This musculoskeletal modelling study shows that wearing the exoskeleton may reduce lumbar spine loads and may contribute to prevent low back disorders.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
软背外骨骼对人工搬运物料过程中腰椎下部负荷的影响:肌肉骨骼模型研究。
本研究的目的是在一个经过验证的肌肉骨骼模型上附加一个被动软背外骨骼,并评估其在减轻腰部负荷方面的效果。15 名参与者在穿戴或未穿戴 CORFOR® 外骨骼的情况下抬起一个箱子。使用全身 OpenSim 模型估算腰部关节力矩和反作用力,以及腰部肌肉力量。穿戴外骨骼后,屈曲力矩峰值、肌肉力峰值以及压缩力和剪切力峰值均有所降低。这项肌肉骨骼建模研究表明,穿戴外骨骼可减轻腰椎负荷,有助于预防腰背疾病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
期刊最新文献
Accurate detection of gait events using neural networks and IMU data mimicking real-world smartphone usage. Exploring coronavirus sequence motifs through convolutional neural network for accurate identification of COVID-19. Coexistence of horizontal bone loss and dehiscence with the bundle and conventional fiber post: a finite element analysis. Effects of a soft back exoskeleton on lower lumbar spine loads during manual materials handling: a musculoskeletal modelling study. Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1