Xiaobing Fan, Aritrick Chatterjee, Milica Medved, Tatjana Antic, Aytekin Oto, Gregory S Karczmar
{"title":"Introduction to matrix-based method for analyzing hybrid multidimensional prostate MRI data.","authors":"Xiaobing Fan, Aritrick Chatterjee, Milica Medved, Tatjana Antic, Aytekin Oto, Gregory S Karczmar","doi":"10.1002/acm2.14544","DOIUrl":null,"url":null,"abstract":"<p><p>A new approach to analysis of prostate hybrid multidimensional MRI (HM-MRI) data was introduced in this study. HM-MRI data were acquired for a combination of a few echo times (TEs) and a few b-values. Naturally, there is a matrix associated with HM-MRI data for each image pixel. To process the data, we first linearized HM-MRI data by taking the natural logarithm of the imaging signal intensity. Subsequently, a hybrid symmetric matrix was constructed by multiplying the matrix for each pixel by its own transpose. The eigenvalues for each pixel could then be calculated from the hybrid symmetric matrix. In order to compare eigenvalues between patients, three b-values and three TEs were used, because this was smallest number of b-values and TEs among all patients. The results of eigenvalues were displayed as qualitative color maps for easier visualization. For quantitative analysis, the ratio (λ<sub>r</sub>) of eigenvalues (λ<sub>1</sub>, λ<sub>2</sub>, λ<sub>3</sub>) was defined as λ<sub>r</sub> = (λ<sub>1</sub>/λ<sub>2</sub>)/λ<sub>3</sub> to compare region of interest (ROI) between prostate cancer (PCa) and normal tissue. The results show that the combined eigenvalue maps show PCas clearly and these maps are quite different from apparent diffusion coefficient (ADC) and T2 maps of the same prostate. The PCa has significant larger λ<sub>r</sub>, smaller ADC and smaller T2 values than normal prostate tissue (p < 0.001). This suggests that the matrix-based method for analyzing HM-MRI data provides new information that may be clinically useful. The method is easy to use and could be easily implemented in clinical practice. The eigenvalues are associated with combination of ADC and T2 values, and could aid in the identification and staging of PCa.</p>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":" ","pages":"e14544"},"PeriodicalIF":2.0000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/acm2.14544","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
A new approach to analysis of prostate hybrid multidimensional MRI (HM-MRI) data was introduced in this study. HM-MRI data were acquired for a combination of a few echo times (TEs) and a few b-values. Naturally, there is a matrix associated with HM-MRI data for each image pixel. To process the data, we first linearized HM-MRI data by taking the natural logarithm of the imaging signal intensity. Subsequently, a hybrid symmetric matrix was constructed by multiplying the matrix for each pixel by its own transpose. The eigenvalues for each pixel could then be calculated from the hybrid symmetric matrix. In order to compare eigenvalues between patients, three b-values and three TEs were used, because this was smallest number of b-values and TEs among all patients. The results of eigenvalues were displayed as qualitative color maps for easier visualization. For quantitative analysis, the ratio (λr) of eigenvalues (λ1, λ2, λ3) was defined as λr = (λ1/λ2)/λ3 to compare region of interest (ROI) between prostate cancer (PCa) and normal tissue. The results show that the combined eigenvalue maps show PCas clearly and these maps are quite different from apparent diffusion coefficient (ADC) and T2 maps of the same prostate. The PCa has significant larger λr, smaller ADC and smaller T2 values than normal prostate tissue (p < 0.001). This suggests that the matrix-based method for analyzing HM-MRI data provides new information that may be clinically useful. The method is easy to use and could be easily implemented in clinical practice. The eigenvalues are associated with combination of ADC and T2 values, and could aid in the identification and staging of PCa.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic