Performance of the Implant Disease Risk Assessment in Predicting Peri‐Implantitis: A Retrospective Study

IF 4.8 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Implants Research Pub Date : 2024-12-09 DOI:10.1111/clr.14390
Nathalia Vilela, Bruno C. V. Gurgel, Christina M. Rostant, Karin C. Schey, Krishna Mukesh Vekariya, Hélio D. P. da Silva, Claudio M. Pannuti, Poliana M. Duarte
{"title":"Performance of the Implant Disease Risk Assessment in Predicting Peri‐Implantitis: A Retrospective Study","authors":"Nathalia Vilela, Bruno C. V. Gurgel, Christina M. Rostant, Karin C. Schey, Krishna Mukesh Vekariya, Hélio D. P. da Silva, Claudio M. Pannuti, Poliana M. Duarte","doi":"10.1111/clr.14390","DOIUrl":null,"url":null,"abstract":"ObjectiveThis university‐based retrospective study aimed to assess the performance of the implant disease risk assessment (IDRA) in predicting peri‐implantitis.Material and MethodsPatients with implants loaded for at least 1 year were included. Peri‐implantitis development was the outcome, while the IDRA score and its eight vectors were the predictors. The IDRA score was calculated using an online tool. Data were analyzed using Cox proportional hazards models and ROC curve (AUC).ResultsAmong 480 implants in 235 patients, 7.9% of implants and 9.4% of patients developed peri‐implantitis. Implants at high risk for the “number of sites with PD ≥ 5 mm” vector had an increased risk (HR = 9.8, <jats:italic>p</jats:italic> = 0.004) of peri‐implantitis, compared to those at low risk for this parameter. Implants at moderate (HR = 4.8, <jats:italic>p</jats:italic> = 0.04) and high (HR = 10.0, <jats:italic>p</jats:italic> = 0.01) risk for the “distance from the restorative margin (RM) to bone crest (BC)” vector exhibited a higher risk of peri‐implantitis than implants at low risk for this parameter. The IDRA tool demonstrated an AUC of 0.66 (sensitivity = 0.80; specificity = 0.24) when estimated at implant level and an AUC of 0.61 (sensitivity = 0.91; specificity = 0.32) when calculated at patient level. The mixed‐effects Cox model did not reveal a significant association between the overall IDRA score and the development of peri‐implantitis (HR = 7.2, <jats:italic>p</jats:italic> = 0.18).ConclusionIDRA demonstrates good sensitivity but low specificity and suboptimal discriminatory capacity in predicting peri‐implantitis. The “number of sites with PD ≥ 5 mm” and “distance from RM to BC” emerged as the most effective predictors for peri‐implantitis.","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"19 1","pages":""},"PeriodicalIF":4.8000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/clr.14390","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

ObjectiveThis university‐based retrospective study aimed to assess the performance of the implant disease risk assessment (IDRA) in predicting peri‐implantitis.Material and MethodsPatients with implants loaded for at least 1 year were included. Peri‐implantitis development was the outcome, while the IDRA score and its eight vectors were the predictors. The IDRA score was calculated using an online tool. Data were analyzed using Cox proportional hazards models and ROC curve (AUC).ResultsAmong 480 implants in 235 patients, 7.9% of implants and 9.4% of patients developed peri‐implantitis. Implants at high risk for the “number of sites with PD ≥ 5 mm” vector had an increased risk (HR = 9.8, p = 0.004) of peri‐implantitis, compared to those at low risk for this parameter. Implants at moderate (HR = 4.8, p = 0.04) and high (HR = 10.0, p = 0.01) risk for the “distance from the restorative margin (RM) to bone crest (BC)” vector exhibited a higher risk of peri‐implantitis than implants at low risk for this parameter. The IDRA tool demonstrated an AUC of 0.66 (sensitivity = 0.80; specificity = 0.24) when estimated at implant level and an AUC of 0.61 (sensitivity = 0.91; specificity = 0.32) when calculated at patient level. The mixed‐effects Cox model did not reveal a significant association between the overall IDRA score and the development of peri‐implantitis (HR = 7.2, p = 0.18).ConclusionIDRA demonstrates good sensitivity but low specificity and suboptimal discriminatory capacity in predicting peri‐implantitis. The “number of sites with PD ≥ 5 mm” and “distance from RM to BC” emerged as the most effective predictors for peri‐implantitis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
种植体疾病风险评估在预测种植体周围炎中的表现:一项回顾性研究
目的:本回顾性研究旨在评估种植体疾病风险评估(IDRA)在预测种植体周围炎方面的表现。材料和方法纳入植入植入物至少1年的患者。种植体周围炎的发展是结局,而IDRA评分及其8个载体是预测因子。IDRA评分使用在线工具计算。采用Cox比例风险模型和ROC曲线(AUC)对数据进行分析。结果235例患者480例种植体中,7.9%的种植体和9.4%的患者发生种植体周围炎。与低风险的种植体相比,“PD≥5 mm的位点数量”载体的高风险种植体患种植体周围炎的风险增加(HR = 9.8, p = 0.004)。中度(HR = 4.8, p = 0.04)和高(HR = 10.0, p = 0.01)风险“从修复缘(RM)到骨嵴(BC)的距离”载体的种植体比低风险的种植体表现出更高的种植体周围炎风险。IDRA工具的AUC为0.66(灵敏度= 0.80;特异性= 0.24),AUC为0.61(敏感性= 0.91;在患者水平上计算特异性= 0.32)。混合效应Cox模型未显示总体IDRA评分与种植体周围炎的发生之间存在显著关联(HR = 7.2, p = 0.18)。结论idra在预测种植体周围炎方面具有良好的敏感性,但特异性较低,区分能力不佳。“PD≥5mm的部位数量”和“从RM到BC的距离”成为种植体周围炎最有效的预测指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Oral Implants Research
Clinical Oral Implants Research 医学-工程:生物医学
CiteScore
7.70
自引率
11.60%
发文量
149
审稿时长
3 months
期刊介绍: Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.
期刊最新文献
The Effect of Different Socket Morphologies of a Maxillary Central Incisor on the Accuracy of Immediate Implants Placed With Freehand or Guided Surgery—An In Vitro Study Comparison of Two Different Sizes of Deproteinized Bovine Bone Mineral Particles in Lateral Sinus Floor Elevation With Simultaneous Implant Placement: A Radiographic Study Accuracy of a Novel Robot‐Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study Peri-Implant Marginal Bone Changes Using High-Speed Drilling With Irrigation Versus Low-Speed Drilling Without Irrigation: A Randomized Clinical Trial With 12 Months of Follow-Up. Cover Image
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1