Additively manufactured ready-to-use platform using conductive recycled PLA for ketamine sensing

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchimica Acta Pub Date : 2025-01-09 DOI:10.1007/s00604-024-06902-3
Maria M. C. Souza, Raquel G. Rocha, Gilvana P. Siqueira, Robert D. Crapnell, Eduardo M. Richter, Craig E. Banks, Rodrigo A. A. Muñoz
{"title":"Additively manufactured ready-to-use platform using conductive recycled PLA for ketamine sensing","authors":"Maria M. C. Souza,&nbsp;Raquel G. Rocha,&nbsp;Gilvana P. Siqueira,&nbsp;Robert D. Crapnell,&nbsp;Eduardo M. Richter,&nbsp;Craig E. Banks,&nbsp;Rodrigo A. A. Muñoz","doi":"10.1007/s00604-024-06902-3","DOIUrl":null,"url":null,"abstract":"<div><p>The use of 3D-printed electrodes is reported fabricated from in-house conductive filament composed of a mixture of recycled poly (lactic acid) (rPLA), graphite (Gpt), and carbon black (CB) for fast detection of the abused drug ketamine. Firstly, the performance of these electrodes was evaluated in comparison to 3D-printed electrodes produced employing a commercially available conductive filament. After a simple pretreatment step (mechanical polishing), the new 3D-printed electrodes presented better performance than the electrodes produced from commercial filament in relation to peak-to-peak separation of the redox probe [Fe(CN)<sub>6</sub>]<sup>3-</sup>/<sup>4-</sup> (130 mV and 759 mV, respectively), charge transfer resistance (R<sub>ct</sub> = 1.04 ± 0.05 kΩ and 9.62 ± 0.03 kΩ, respectively), and heterogeneous rate constant (k<sup>0</sup> = 7.16 ± 0.05 × 10<sup>–3</sup> cm s<sup>−1</sup> and 3.57 ± 0.03 × 10<sup>–3</sup> cm s<sup>-1</sup>, respectively). Excellent analytical characteristics for the detection of ketamine were achieved, including wide linear range (10 to 250 μmol L<sup>-1</sup>), excellent sensitivity (0.024 ± 0.001 μA μmol L<sup>-1</sup>), low limit of detection (LOD = 0.7 μmol L<sup>-1</sup>), and recovery values from 82 to 115% for beverage samples (white and red wines, beer, water, and vodka) spiked with the abused drug ketamine.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 2","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-024-06902-3","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The use of 3D-printed electrodes is reported fabricated from in-house conductive filament composed of a mixture of recycled poly (lactic acid) (rPLA), graphite (Gpt), and carbon black (CB) for fast detection of the abused drug ketamine. Firstly, the performance of these electrodes was evaluated in comparison to 3D-printed electrodes produced employing a commercially available conductive filament. After a simple pretreatment step (mechanical polishing), the new 3D-printed electrodes presented better performance than the electrodes produced from commercial filament in relation to peak-to-peak separation of the redox probe [Fe(CN)6]3-/4- (130 mV and 759 mV, respectively), charge transfer resistance (Rct = 1.04 ± 0.05 kΩ and 9.62 ± 0.03 kΩ, respectively), and heterogeneous rate constant (k0 = 7.16 ± 0.05 × 10–3 cm s−1 and 3.57 ± 0.03 × 10–3 cm s-1, respectively). Excellent analytical characteristics for the detection of ketamine were achieved, including wide linear range (10 to 250 μmol L-1), excellent sensitivity (0.024 ± 0.001 μA μmol L-1), low limit of detection (LOD = 0.7 μmol L-1), and recovery values from 82 to 115% for beverage samples (white and red wines, beer, water, and vodka) spiked with the abused drug ketamine.

Graphical Abstract

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
期刊最新文献
Eu3+-ion doped strontium molybdate perovskite quantum dots as a turn-off-on fluorescent sensor for simultaneous detection of hypoxanthine biomarker and Fe3+ ions Sensitive and selective colorimetric detection of thiophanate-methyl based on a novel Ru-Fe3O4 nanozyme with enhanced peroxidase-like activity Smartphone-assisted hydrogel sensing platform based on double emission carbon dots for portable on-site tetracycline detection Ecofriendly and biocompatible biochars derived from waste-branches for direct and efficient solid-phase extraction of benzodiazepines in crude urine sample prior to LC–MS/MS Additively manufactured ready-to-use platform using conductive recycled PLA for ketamine sensing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1