Automated detection of traumatic bleeding in CT images using 3D U-Net# and multi-organ segmentation.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Biomedical Physics & Engineering Express Pub Date : 2025-01-24 DOI:10.1088/2057-1976/adae14
Rizki Nurfauzi, Ayaka Baba, Taka-Aki Nakada, Toshiya Nakaguchi, Yukihiro Nomura
{"title":"Automated detection of traumatic bleeding in CT images using 3D U-Net# and multi-organ segmentation.","authors":"Rizki Nurfauzi, Ayaka Baba, Taka-Aki Nakada, Toshiya Nakaguchi, Yukihiro Nomura","doi":"10.1088/2057-1976/adae14","DOIUrl":null,"url":null,"abstract":"<p><p>Traumatic injury remains a leading cause of death worldwide, with traumatic bleeding being one of its most critical and fatal consequences. The use of whole-body computed tomography (WBCT) in trauma management has rapidly expanded. However, interpreting WBCT images within the limited time available before treatment is particularly challenging for acute care physicians. Our group has previously developed an automated bleeding detection method in WBCT images. However, further reduction of false positives (FPs) is necessary for clinical application. To address this issue, we propose a novel automated detection for traumatic bleeding in CT images using deep learning and multi-organ segmentation; Methods: The proposed method integrates a three-dimensional U-Net# model for bleeding detection with an FP reduction approach based on multi-organ segmentation. The multi-organ segmentation method targets the bone, kidney, and vascular regions, where FPs are primarily found during the bleeding detection process. We evaluated the proposed method using a dataset of delayed-phase contrast-enhanced trauma CT images collected from four institutions; Results: Our method detected 70.0% of bleedings with 76.2 FPs/case. The processing time for our method was 6.3 ± 1.4 min. Compared with our previous ap-proach, the proposed method significantly reduced the number of FPs while maintaining detection sensitivity.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/adae14","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Traumatic injury remains a leading cause of death worldwide, with traumatic bleeding being one of its most critical and fatal consequences. The use of whole-body computed tomography (WBCT) in trauma management has rapidly expanded. However, interpreting WBCT images within the limited time available before treatment is particularly challenging for acute care physicians. Our group has previously developed an automated bleeding detection method in WBCT images. However, further reduction of false positives (FPs) is necessary for clinical application. To address this issue, we propose a novel automated detection for traumatic bleeding in CT images using deep learning and multi-organ segmentation; Methods: The proposed method integrates a three-dimensional U-Net# model for bleeding detection with an FP reduction approach based on multi-organ segmentation. The multi-organ segmentation method targets the bone, kidney, and vascular regions, where FPs are primarily found during the bleeding detection process. We evaluated the proposed method using a dataset of delayed-phase contrast-enhanced trauma CT images collected from four institutions; Results: Our method detected 70.0% of bleedings with 76.2 FPs/case. The processing time for our method was 6.3 ± 1.4 min. Compared with our previous ap-proach, the proposed method significantly reduced the number of FPs while maintaining detection sensitivity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
期刊最新文献
Simulations of the potential for diffraction enhanced imaging at 8 kev using polycapillary optics. Determining event-related desynchronization onset latency of foot dorsiflexion in people with multiple sclerosis using the cluster depth tests. Automated detection of traumatic bleeding in CT images using 3D U-Net# and multi-organ segmentation. External delay and dispersion correction of automatically sampled arterial blood with dual flow rates. Development of a machine learning tool to predict deep inspiration breath hold requirement for locoregional right-sided breast radiation therapy patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1