Development of soft seal and experimental investigation of soft seated safety relief valves for cryogenic applications

IF 2.1 3区 工程技术 Q3 PHYSICS, APPLIED Cryogenics Pub Date : 2025-03-15 Epub Date: 2024-12-12 DOI:10.1016/j.cryogenics.2024.104005
N. Sreekanth , S. Sankaran , Jack J. Kenned
{"title":"Development of soft seal and experimental investigation of soft seated safety relief valves for cryogenic applications","authors":"N. Sreekanth ,&nbsp;S. Sankaran ,&nbsp;Jack J. Kenned","doi":"10.1016/j.cryogenics.2024.104005","DOIUrl":null,"url":null,"abstract":"<div><div>Cryogenic propellant servicing of any advanced propulsion system before launch is very critical due to complex two phase flow during chilling, transient heat transfer, pressure and temperature management. Metal seated safety valves are generally prone to seat leakage due to surface roughness and even small degree of leak across seat is not acceptable for usage in cryogenic applications.<!--> <!-->In this study, the seat leakage across metal seated valves is mitigated by designing and developing a unique soft seal to replace metal seated safety valve seat. An experimental investigation is carried out to validate the developed soft-seated valve with ambient gases such as nitrogen and highly sensitive mass spectrometer test with gaseous helium. Liquid nitrogen tests are conducted to validate the performance of the developed soft seated valve at cryogenic temperatures. In addition, semi-empirical computations have been done based on contact surface characteristics and deformation analysis to assess seat leak rates with gaseous helium. The experimental test results indicated that the seat leak rate improved with increased cyclic operations compared to metal seated valves. The sealing characteristics improved to 0.61 x 10<sup>−6</sup> mbar.l/sec from 4.72 x 10<sup>−5</sup> mbar.l/sec at liquid nitrogen temperature. The computations of leak rate obtained by semi empirical computations was compared to that of experimental results and are found to be in close agreement. The results indicated the developed soft seated valve meets the leakage class requirements for cryogenic applications and can be applied to metal seated valve.</div></div>","PeriodicalId":10812,"journal":{"name":"Cryogenics","volume":"146 ","pages":"Article 104005"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cryogenics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S001122752400225X","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

Cryogenic propellant servicing of any advanced propulsion system before launch is very critical due to complex two phase flow during chilling, transient heat transfer, pressure and temperature management. Metal seated safety valves are generally prone to seat leakage due to surface roughness and even small degree of leak across seat is not acceptable for usage in cryogenic applications. In this study, the seat leakage across metal seated valves is mitigated by designing and developing a unique soft seal to replace metal seated safety valve seat. An experimental investigation is carried out to validate the developed soft-seated valve with ambient gases such as nitrogen and highly sensitive mass spectrometer test with gaseous helium. Liquid nitrogen tests are conducted to validate the performance of the developed soft seated valve at cryogenic temperatures. In addition, semi-empirical computations have been done based on contact surface characteristics and deformation analysis to assess seat leak rates with gaseous helium. The experimental test results indicated that the seat leak rate improved with increased cyclic operations compared to metal seated valves. The sealing characteristics improved to 0.61 x 10−6 mbar.l/sec from 4.72 x 10−5 mbar.l/sec at liquid nitrogen temperature. The computations of leak rate obtained by semi empirical computations was compared to that of experimental results and are found to be in close agreement. The results indicated the developed soft seated valve meets the leakage class requirements for cryogenic applications and can be applied to metal seated valve.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低温软密封安全安全阀的研制与试验研究
由于在冷却、瞬态传热、压力和温度管理过程中复杂的两相流,任何先进推进系统在发射前的低温推进剂维修都是非常关键的。由于表面粗糙度,金属阀座安全阀通常容易发生阀座泄漏,并且在低温应用中,即使是阀座上的小程度泄漏也是不可接受的。在这项研究中,通过设计和开发一种独特的软密封来取代金属阀座安全阀座,减轻了金属阀座泄漏。对所研制的软阀座进行了环境气体(氮气)和高灵敏度质谱(气氦)测试的实验研究。通过液氮试验验证了所研制的软阀座在低温下的性能。此外,基于接触面特性和变形分析进行了半经验计算,评估了气氦阀座泄漏率。试验结果表明,与金属阀座相比,随着循环次数的增加,阀座泄漏率有所提高。密封性能提高到0.61 x 10−6 mbar。L /秒从4.72 × 10 - 5毫巴。L /s在液氮温度下。将半经验计算得到的泄漏率与实验结果进行了比较,两者吻合较好。结果表明,所研制的软阀座阀满足低温应用的泄漏等级要求,可应用于金属阀座阀。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Cryogenics
Cryogenics 物理-热力学
CiteScore
3.80
自引率
9.50%
发文量
0
审稿时长
2.1 months
期刊介绍: Cryogenics is the world''s leading journal focusing on all aspects of cryoengineering and cryogenics. Papers published in Cryogenics cover a wide variety of subjects in low temperature engineering and research. Among the areas covered are: - Applications of superconductivity: magnets, electronics, devices - Superconductors and their properties - Properties of materials: metals, alloys, composites, polymers, insulations - New applications of cryogenic technology to processes, devices, machinery - Refrigeration and liquefaction technology - Thermodynamics - Fluid properties and fluid mechanics - Heat transfer - Thermometry and measurement science - Cryogenics in medicine - Cryoelectronics
期刊最新文献
Influence of cryogenic temperatures on low velocity impact and compression characteristics of GFRP pipes Improving the estimation of the hydrogen storage density in a cryo-compressed hydrogen tank using an unscented Kalman filter Performance of cryogenic insulations through steady-state and loss of vacuum conditions between 20 and 300 K An effective strategy for mitigating the demagnetization of bulk GdBa2Cu3Oy superconductors under transverse fields Experimental assessment and comparative analysis of active magnetic regenerative refrigeration for hydrogen liquefaction using HoAl2 and ErAl2
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1