Investigation of factors related to treatment planning of x-ray SBRT and scanning carbon-ion radiation therapy for early-stage lung cancer patients

IF 2.2 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Applied Clinical Medical Physics Pub Date : 2025-02-11 DOI:10.1002/acm2.14618
Yuya Miyasaka, Sung Hyun Lee, Hikaru Souda, Hongbo Chai, Miyu Ishizawa, Takuya Ono, Takashi Ono, Hiraku Sato, Takeo Iwai
{"title":"Investigation of factors related to treatment planning of x-ray SBRT and scanning carbon-ion radiation therapy for early-stage lung cancer patients","authors":"Yuya Miyasaka,&nbsp;Sung Hyun Lee,&nbsp;Hikaru Souda,&nbsp;Hongbo Chai,&nbsp;Miyu Ishizawa,&nbsp;Takuya Ono,&nbsp;Takashi Ono,&nbsp;Hiraku Sato,&nbsp;Takeo Iwai","doi":"10.1002/acm2.14618","DOIUrl":null,"url":null,"abstract":"<p>This study aimed to compare the treatment plans of x-ray SBRT and scanning carbon ion radiation therapy (CIRT) for localized lung tumors, and to evaluate the dose dependence of tumor size tumor-to-heart distance. For phantom verification, we used a chest phantom with a spherical simulated tumor. Treatment plans for 3-dimensional conformal radiation therapy (3D-CRT), volumetric modulated arc therapy (VMAT), and CIRT were created. GTVs were created in sizes ranging from 0.5 to 5 cm in diameter, and the dependence of the lung dose on GTV diameter was evaluated for each treatment plan. For patient validation, 30 cases of localized lung tumors were analyzed. 3D-CRT, VMAT, and CIRT treatment plans were developed, and DVH parameters were evaluated for each GTV size and GTV-to-heart distance. In both phantom and patient validations, the OAR doses were the lowest for CIRT. The lung dose increased with increasing GTV diameter for all three treatment plans. CIRT had the smallest ratio of lung dose increase to GTV diameter increase among the three treatment plans. Heart dose in CIRT was independent of GTV size and GTV-to-heart distance Conclusions: The results of the present study suggested that the use of scanning CIRT can reduce the OAR dose while guaranteeing the tumor dose compared to x-ray SBRT. In addition, it was suggested that CIRT can treat patients with large GTV sizes while maintaining low lung and heart dose.</p>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"26 4","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.14618","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://aapm.onlinelibrary.wiley.com/doi/10.1002/acm2.14618","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to compare the treatment plans of x-ray SBRT and scanning carbon ion radiation therapy (CIRT) for localized lung tumors, and to evaluate the dose dependence of tumor size tumor-to-heart distance. For phantom verification, we used a chest phantom with a spherical simulated tumor. Treatment plans for 3-dimensional conformal radiation therapy (3D-CRT), volumetric modulated arc therapy (VMAT), and CIRT were created. GTVs were created in sizes ranging from 0.5 to 5 cm in diameter, and the dependence of the lung dose on GTV diameter was evaluated for each treatment plan. For patient validation, 30 cases of localized lung tumors were analyzed. 3D-CRT, VMAT, and CIRT treatment plans were developed, and DVH parameters were evaluated for each GTV size and GTV-to-heart distance. In both phantom and patient validations, the OAR doses were the lowest for CIRT. The lung dose increased with increasing GTV diameter for all three treatment plans. CIRT had the smallest ratio of lung dose increase to GTV diameter increase among the three treatment plans. Heart dose in CIRT was independent of GTV size and GTV-to-heart distance Conclusions: The results of the present study suggested that the use of scanning CIRT can reduce the OAR dose while guaranteeing the tumor dose compared to x-ray SBRT. In addition, it was suggested that CIRT can treat patients with large GTV sizes while maintaining low lung and heart dose.

Abstract Image

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
早期肺癌x线SBRT及扫描碳离子放射治疗方案的影响因素探讨
本研究旨在比较x线SBRT和扫描碳离子放射治疗(CIRT)治疗局限性肺肿瘤的方案,并评估肿瘤大小与肿瘤到心脏距离的剂量依赖性。为了验证假体,我们使用了一个带有球形模拟肿瘤的胸部假体。制定了三维适形放射治疗(3D-CRT)、体积调制电弧治疗(VMAT)和CIRT的治疗计划。制造的GTV直径范围为0.5至5cm,并评估每个治疗方案的肺剂量与GTV直径的依赖关系。为了患者的验证,我们分析了30例局限性肺肿瘤。制定3D-CRT、VMAT和CIRT治疗方案,并评估每个GTV尺寸和GTV到心脏距离的DVH参数。在幻影和患者验证中,对于CIRT, OAR剂量是最低的。在所有三种治疗方案中,肺剂量随GTV直径的增加而增加。三种治疗方案中,CIRT肺剂量增加与GTV直径增加的比例最小。结论:本研究结果表明,与x线SBRT相比,使用扫描型CIRT可以在保证肿瘤剂量的同时降低OAR剂量。此外,提示CIRT可以在维持低肺和心脏剂量的情况下治疗GTV大的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.60
自引率
19.00%
发文量
331
审稿时长
3 months
期刊介绍: Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission. JACMP will publish: -Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500. -Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed. -Technical Notes: These should be no longer than 3000 words, including key references. -Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents. -Book Reviews: The editorial office solicits Book Reviews. -Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics. -Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic
期刊最新文献
Interpretable LightGBM model with SHAP analysis predicts non-excellent response to initial radioiodine therapy in differentiated thyroid carcinoma. Knowledge, attitude, and practice regarding radiation exposure and protection among diagnostic radiographers in radiology departments in Shanghai, China. Automated identification of radiotherapy treatment sites from unstructured physician notes. Computed tomography for four-dimensional dose calculation: Effect of detector array length. The role of abdominal compression in the reduction of respiratory motion for cardiac radioablation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1