Reliability, failure mode, and stress distribution in conical connections with different types of retention.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2025-02-12 DOI:10.1016/j.prosdent.2025.01.013
Michele Costa de Oliveira Ribeiro, Vanessa Felipe Vargas-Moreno, Rafael Soares Gomes, Edmara Tatiely Pedroso Bergamo, Estevam Augusto Bonfante, Altair Antoninha Del Bel Cury, Raissa Micaella Marcello-Machado
{"title":"Reliability, failure mode, and stress distribution in conical connections with different types of retention.","authors":"Michele Costa de Oliveira Ribeiro, Vanessa Felipe Vargas-Moreno, Rafael Soares Gomes, Edmara Tatiely Pedroso Bergamo, Estevam Augusto Bonfante, Altair Antoninha Del Bel Cury, Raissa Micaella Marcello-Machado","doi":"10.1016/j.prosdent.2025.01.013","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>The tapered interference fit (TIF) implant system, a screwless system with purely frictional retention, was developed to minimize prosthetic complications associated with screw loosening. However, evidence regarding its biomechanical behavior is scarce.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to compare the reliability, failure mode, and stress distribution of frictional TIF implant systems with straight and custom in-office angled abutments and conventional taper integrated screw-in (TIS) systems.</p><p><strong>Material and methods: </strong>One hundred and five implants with single crowns were divided into 5 groups (n=21) according to the type of retention (TIF or TIS) and angulation of the abutment, straight (S) or angled (A): straight universal abutment (TIF); 17-degree angled abutment (TIF-A); straight universal abutment (TIS); 17-degree angled abutment (TIS-A); and straight abutment with passing screw (TIS-P). The reliability was assessed by step-stress accelerated life testing (SSALT) (n=21). The failure mode was investigated using fractographic analysis. Finite element analysis (FEA) was performed to analyze stress distribution. The von Mises stress (σvM) and displacement were assessed for implant and abutment, while shear stress (τmax) and minimum principal stress (σmin) were evaluated for cortical and cancellous bone.</p><p><strong>Results: </strong>All groups presented high reliability at a load of 100 N. The TIS-P (93%) showed lower reliability than the TIF and TIS-A (99%) groups. However, with the increase of load to 150 N, the reliability of the TIS (60%), TIS-P (82%), and TIF-A (81%) groups decreased. No changes were observed for TIF and TIS-A. All specimens failed by fracture after SSALT, with failures restricted to the transmucosal area of the abutment. FEA showed an increase in σvM of at least 60% in the abutment for the TIF groups, while a reduction of 64% was observed in the implant. The displacement was greater for TIF (54.36 mm) in the abutment and higher for TIS-P (6.97 µm) in the implant. Also, the TIF and TIF-A groups exhibited better cortical and cancellous bone stress distribution.</p><p><strong>Conclusions: </strong>The TIF systems can be safely indicated for implant-supported prostheses in the anterior region because of their high reliability and excellent stress distribution to the bone. Custom in-office angulation may decrease reliability, suggesting a preference TIS systems.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2025.01.013","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: The tapered interference fit (TIF) implant system, a screwless system with purely frictional retention, was developed to minimize prosthetic complications associated with screw loosening. However, evidence regarding its biomechanical behavior is scarce.

Purpose: The purpose of this in vitro study was to compare the reliability, failure mode, and stress distribution of frictional TIF implant systems with straight and custom in-office angled abutments and conventional taper integrated screw-in (TIS) systems.

Material and methods: One hundred and five implants with single crowns were divided into 5 groups (n=21) according to the type of retention (TIF or TIS) and angulation of the abutment, straight (S) or angled (A): straight universal abutment (TIF); 17-degree angled abutment (TIF-A); straight universal abutment (TIS); 17-degree angled abutment (TIS-A); and straight abutment with passing screw (TIS-P). The reliability was assessed by step-stress accelerated life testing (SSALT) (n=21). The failure mode was investigated using fractographic analysis. Finite element analysis (FEA) was performed to analyze stress distribution. The von Mises stress (σvM) and displacement were assessed for implant and abutment, while shear stress (τmax) and minimum principal stress (σmin) were evaluated for cortical and cancellous bone.

Results: All groups presented high reliability at a load of 100 N. The TIS-P (93%) showed lower reliability than the TIF and TIS-A (99%) groups. However, with the increase of load to 150 N, the reliability of the TIS (60%), TIS-P (82%), and TIF-A (81%) groups decreased. No changes were observed for TIF and TIS-A. All specimens failed by fracture after SSALT, with failures restricted to the transmucosal area of the abutment. FEA showed an increase in σvM of at least 60% in the abutment for the TIF groups, while a reduction of 64% was observed in the implant. The displacement was greater for TIF (54.36 mm) in the abutment and higher for TIS-P (6.97 µm) in the implant. Also, the TIF and TIF-A groups exhibited better cortical and cancellous bone stress distribution.

Conclusions: The TIF systems can be safely indicated for implant-supported prostheses in the anterior region because of their high reliability and excellent stress distribution to the bone. Custom in-office angulation may decrease reliability, suggesting a preference TIS systems.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Digital workflow for fabricating a nasal apex-columella prosthesis with an integrated custom nasal stent. Guided tissue regeneration with a gelatin and polycaprolactone composite membrane for repairing oral soft tissue defects: A prospective, single-blinded, randomized trial. Influence of polymerization protocols on the physical and mechanical properties of a 3D printed resin. Mechanical properties and reliability of an additively manufactured resin incorporated with a commercially available ceramic composite concentrate. Reliability, failure mode, and stress distribution in conical connections with different types of retention.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1