Ultrasound of the uterosacral ligaments: A reliability study for diagnosing endometriosis in Australian non-specialised medical imaging and radiology settings

Shae Maple, Eva Bezak, K Jane Chalmers, Nayana Parange
{"title":"Ultrasound of the uterosacral ligaments: A reliability study for diagnosing endometriosis in Australian non-specialised medical imaging and radiology settings","authors":"Shae Maple,&nbsp;Eva Bezak,&nbsp;K Jane Chalmers,&nbsp;Nayana Parange","doi":"10.1002/ajum.12420","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction/Background</h3>\n \n <p>Uterosacral ligaments (USL) are the most common sites of endometriosis. Transvaginal ultrasound (TVS) demonstrates high diagnostic accuracy for endometriosis of the USLs using standardised technique and characterisations. While high accuracy and reproducibility is established with these techniques by well-trained professionals, the question still remains if these techniques are reproducible in general settings. This study aims to assess the intra and interobserver agreement of TVS characteristics of USLs, between experienced and less experienced examiners in an Australian general ultrasound imaging practice, where sonographers are required to perform ultrasound for endometriosis.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Forty-two patients, with and without known endometriosis, underwent ultrasound imaging of the USLs. Images were obtained of uterosacral ligaments and collated for interobserver survey. Six professional observers independently reviewed the images, classifying characteristics such as echogenicity, echotexture, contour, thickness, and presence of nodules. Interobserver reliability was assessed using Gwet's agreement coefficients (<i>AC1</i>), and the correlation between USL thickness and endometriosis was analyzed using Spearman's correlation.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Interobserver agreement for detecting USL endometriosis was substantial (<i>AC1</i> = 0.63), with an overall agreement of (0.65) for the seven USL characteristics. Intraobserver agreement ranged from moderate (0.60) to almost perfect (0.96). Experience did not significantly affect intraobserver reliability. A strong positive correlation was found between USL thickness and endometriosis (r = 0.7965, P &lt; 0.01).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>This study demonstrates high inter and intraobserver agreement among sonographers and radiologists in a general imaging department for identifying USL characteristics and diagnosing USL endometriosis. Both experienced and less experienced operators can reliably assess USLs Consistency was shown in identifying thickened uterosacral ligaments however, there is no consensus on where uterosacral ligament be measured. Even so, a thickened USL can prompt further extension of the pelvic scan to look for other endometriosis markers.</p>\n </section>\n </div>","PeriodicalId":36517,"journal":{"name":"Australasian Journal of Ultrasound in Medicine","volume":"28 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ajum.12420","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australasian Journal of Ultrasound in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ajum.12420","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction/Background

Uterosacral ligaments (USL) are the most common sites of endometriosis. Transvaginal ultrasound (TVS) demonstrates high diagnostic accuracy for endometriosis of the USLs using standardised technique and characterisations. While high accuracy and reproducibility is established with these techniques by well-trained professionals, the question still remains if these techniques are reproducible in general settings. This study aims to assess the intra and interobserver agreement of TVS characteristics of USLs, between experienced and less experienced examiners in an Australian general ultrasound imaging practice, where sonographers are required to perform ultrasound for endometriosis.

Methods

Forty-two patients, with and without known endometriosis, underwent ultrasound imaging of the USLs. Images were obtained of uterosacral ligaments and collated for interobserver survey. Six professional observers independently reviewed the images, classifying characteristics such as echogenicity, echotexture, contour, thickness, and presence of nodules. Interobserver reliability was assessed using Gwet's agreement coefficients (AC1), and the correlation between USL thickness and endometriosis was analyzed using Spearman's correlation.

Results

Interobserver agreement for detecting USL endometriosis was substantial (AC1 = 0.63), with an overall agreement of (0.65) for the seven USL characteristics. Intraobserver agreement ranged from moderate (0.60) to almost perfect (0.96). Experience did not significantly affect intraobserver reliability. A strong positive correlation was found between USL thickness and endometriosis (r = 0.7965, P < 0.01).

Conclusion

This study demonstrates high inter and intraobserver agreement among sonographers and radiologists in a general imaging department for identifying USL characteristics and diagnosing USL endometriosis. Both experienced and less experienced operators can reliably assess USLs Consistency was shown in identifying thickened uterosacral ligaments however, there is no consensus on where uterosacral ligament be measured. Even so, a thickened USL can prompt further extension of the pelvic scan to look for other endometriosis markers.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Australasian Journal of Ultrasound in Medicine
Australasian Journal of Ultrasound in Medicine Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.90
自引率
0.00%
发文量
40
期刊最新文献
Ultrasound of the uterosacral ligaments: A reliability study for diagnosing endometriosis in Australian non-specialised medical imaging and radiology settings Hepatic abscess caused by foreign body ingestion: A case report An innovative hybrid training method for ultrasound in giant cell arteritis, polymyalgia rheumatica and large vessel vasculitis Issue Information Application of the 2023 World Heart Federation guidelines for the echocardiographic diagnosis of rheumatic heart disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1