Systematic Study of Silicon Carbide Detectors and Beam Current Transformer Signals for UHDR Single Electron Pulse Monitoring.

IF 2.5 3区 医学 Q2 BIOLOGY Radiation research Pub Date : 2025-02-25 DOI:10.1667/RADE-24-00139.1
C Okpuwe, G Milluzzo, D Coves, T Delaviere, D Del Sarto, M De Napoli, F Di Martino, G Felici, L Lanzanò, L Masturzo, J Pensavalle, E Touzain, M Camarda, F Romano
{"title":"Systematic Study of Silicon Carbide Detectors and Beam Current Transformer Signals for UHDR Single Electron Pulse Monitoring.","authors":"C Okpuwe, G Milluzzo, D Coves, T Delaviere, D Del Sarto, M De Napoli, F Di Martino, G Felici, L Lanzanò, L Masturzo, J Pensavalle, E Touzain, M Camarda, F Romano","doi":"10.1667/RADE-24-00139.1","DOIUrl":null,"url":null,"abstract":"<p><p>The use of ultra-high dose rate beams (UHDR) (> 40 Gy/s) for radiotherapy, despite its advantage of exhibiting the FLASH effect that improves the sparing of healthy tissues, faces challenges in dosimetry and beam monitoring since standard dosimeters like the ionization chamber experience saturation effects at such high dose rates. Silicon carbide (SiC) detectors have recently been demonstrated to be dose-rate independent with low-energy pulsed electron beams up to an instantaneous dose rate of 5.5 MGy/s, and has emerged as a reliable alternative technology for dosimetry in FLASH-RT. This study explored the suitability of using the SiC detector for measuring intra-pulse instantaneous dose rates, which are necessary for monitoring fluctuations within the pulse of UHDR pulsed electron beams. The experiments reported were conducted using UHDR electron beams accelerated at 9 MeV by an ElectronFlash linac and using varying different beam parameters, such as the beam current (i.e., different dose per pulse) and pulse width settings. The temporal single pulse shape signals were measured with a 10 µm thick, 4.5 mm2 area SiC detector for different configurations and compared with a well-characterized AC current transformer (ACCT) (which served as the standard monitoring system of the accelerator), and with a second ACCT placed at the same location as the SiC detector (i.e., after the applicator at the irradiation point). The results show a high level of agreement between the signals of the SiC detector and ACCT placed after the applicator at around the irradiation point. This underscores the potential of the SiC detector and the ACCT to be used for monitoring instantaneous dose rates within a pulse. Furthermore, since use of the SiC detector and ACCT are based on different physical principles, they can provide complementary beam information. A combination of the two has the potential to provide insight about a variety of variables of interest for UHDR beams. However, some discrepancies were observed when comparing the SiC signals with the ACCT installed in the LINAC, which increased linearly with decreasing dose per pulse. Further studies are required to better understand these observations.</p>","PeriodicalId":20903,"journal":{"name":"Radiation research","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1667/RADE-24-00139.1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The use of ultra-high dose rate beams (UHDR) (> 40 Gy/s) for radiotherapy, despite its advantage of exhibiting the FLASH effect that improves the sparing of healthy tissues, faces challenges in dosimetry and beam monitoring since standard dosimeters like the ionization chamber experience saturation effects at such high dose rates. Silicon carbide (SiC) detectors have recently been demonstrated to be dose-rate independent with low-energy pulsed electron beams up to an instantaneous dose rate of 5.5 MGy/s, and has emerged as a reliable alternative technology for dosimetry in FLASH-RT. This study explored the suitability of using the SiC detector for measuring intra-pulse instantaneous dose rates, which are necessary for monitoring fluctuations within the pulse of UHDR pulsed electron beams. The experiments reported were conducted using UHDR electron beams accelerated at 9 MeV by an ElectronFlash linac and using varying different beam parameters, such as the beam current (i.e., different dose per pulse) and pulse width settings. The temporal single pulse shape signals were measured with a 10 µm thick, 4.5 mm2 area SiC detector for different configurations and compared with a well-characterized AC current transformer (ACCT) (which served as the standard monitoring system of the accelerator), and with a second ACCT placed at the same location as the SiC detector (i.e., after the applicator at the irradiation point). The results show a high level of agreement between the signals of the SiC detector and ACCT placed after the applicator at around the irradiation point. This underscores the potential of the SiC detector and the ACCT to be used for monitoring instantaneous dose rates within a pulse. Furthermore, since use of the SiC detector and ACCT are based on different physical principles, they can provide complementary beam information. A combination of the two has the potential to provide insight about a variety of variables of interest for UHDR beams. However, some discrepancies were observed when comparing the SiC signals with the ACCT installed in the LINAC, which increased linearly with decreasing dose per pulse. Further studies are required to better understand these observations.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiation research
Radiation research 医学-核医学
CiteScore
5.10
自引率
8.80%
发文量
179
审稿时长
1 months
期刊介绍: Radiation Research publishes original articles dealing with radiation effects and related subjects in the areas of physics, chemistry, biology and medicine, including epidemiology and translational research. The term radiation is used in its broadest sense and includes specifically ionizing radiation and ultraviolet, visible and infrared light as well as microwaves, ultrasound and heat. Effects may be physical, chemical or biological. Related subjects include (but are not limited to) dosimetry methods and instrumentation, isotope techniques and studies with chemical agents contributing to the understanding of radiation effects.
期刊最新文献
PRMT7 Inhibitor SGC3027 Enhances Radiotherapy Efficacy via Activating ATM Kinase in Non-Small Cell Lung Carcinoma. Plasmid DNA Strand Breaks Are Dose Rate Independent at Clinically Relevant Proton Doses and Under Biological Conditions. Systematic Study of Silicon Carbide Detectors and Beam Current Transformer Signals for UHDR Single Electron Pulse Monitoring. Occupational Exposure to Low Dose Ionizing Radiation and the Incidence of Surgically Removed Cataracts and Glaucoma in a Cohort of Ontario Nuclear Power Plant Workers. Effects of Whole-Body Carbon-Ion Beam Irradiation on Bone Marrow Death in Mice and an Examination of Candidates for Protectors or Mitigators against Carbon-Ion-Beam-Induced Bone Marrow Death.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1