A retinal simulation study on the influence of spherical aberration, astigmatism and optotype on the Jackson cross cylinder test

IF 2.2 Q2 OPHTHALMOLOGY Journal of Optometry Pub Date : 2025-03-08 DOI:10.1016/j.optom.2025.100543
Diana Gargallo, Esther García, Sara Perches, Laura Remón, Jorge Ares
{"title":"A retinal simulation study on the influence of spherical aberration, astigmatism and optotype on the Jackson cross cylinder test","authors":"Diana Gargallo,&nbsp;Esther García,&nbsp;Sara Perches,&nbsp;Laura Remón,&nbsp;Jorge Ares","doi":"10.1016/j.optom.2025.100543","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To study how spherical High-Order Aberration (HOA), astigmatism levels (-0.75 D and -1.25 D), and optotype type (dot pattern vs. letter row) influence patients’ responses in identifying the cylinder axis orientation with the Jackson Cross Cylinder Technique (JCCT).</div></div><div><h3>Methods</h3><div>Numerical simulations of retinal images corresponding to JCCT procedures were conducted and evaluated by 40 subjects. In order to do this, synthetic aberrometric profiles with and without HOAs (4th-order and 6th-order spherical aberrations) and two different astigmatism levels were generated from different Jackson Cross Cylinder axis positions and flips. The variable under study was the percentage of correct responses (hits) during each flip of the cross-cylinder lens. Statistical significance was assessed through confidence intervals overlapping evaluation.</div></div><div><h3>Results</h3><div>To achieve 90 % accuracy, the JCCT should begin by deviating &gt;7.5° from the subject's astigmatism axis without spherical HOA and by &gt;15° with them. The magnitude of astigmatism had minor relevance. The dot pattern was more accurate than the letters without HOAs; however, 72.5 % of observers considered that letter optotypes simplify the blur discrimination task.</div></div><div><h3>Conclusions</h3><div>According to our simulation experiment for astigmatic axis selection with JCCT, the presence of spherical HOAs significantly impacts the accuracy of patient responses. The type of optotype and the magnitude of astigmatism did not exhibit a clear relationship with accuracy, except in the case of the dot pattern optotype in the absence of HOAs. Under these conditions, the dot pattern achieved the highest rate of accurate responses.</div></div>","PeriodicalId":46407,"journal":{"name":"Journal of Optometry","volume":"18 2","pages":"Article 100543"},"PeriodicalIF":2.2000,"publicationDate":"2025-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Optometry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1888429625000093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To study how spherical High-Order Aberration (HOA), astigmatism levels (-0.75 D and -1.25 D), and optotype type (dot pattern vs. letter row) influence patients’ responses in identifying the cylinder axis orientation with the Jackson Cross Cylinder Technique (JCCT).

Methods

Numerical simulations of retinal images corresponding to JCCT procedures were conducted and evaluated by 40 subjects. In order to do this, synthetic aberrometric profiles with and without HOAs (4th-order and 6th-order spherical aberrations) and two different astigmatism levels were generated from different Jackson Cross Cylinder axis positions and flips. The variable under study was the percentage of correct responses (hits) during each flip of the cross-cylinder lens. Statistical significance was assessed through confidence intervals overlapping evaluation.

Results

To achieve 90 % accuracy, the JCCT should begin by deviating >7.5° from the subject's astigmatism axis without spherical HOA and by >15° with them. The magnitude of astigmatism had minor relevance. The dot pattern was more accurate than the letters without HOAs; however, 72.5 % of observers considered that letter optotypes simplify the blur discrimination task.

Conclusions

According to our simulation experiment for astigmatic axis selection with JCCT, the presence of spherical HOAs significantly impacts the accuracy of patient responses. The type of optotype and the magnitude of astigmatism did not exhibit a clear relationship with accuracy, except in the case of the dot pattern optotype in the absence of HOAs. Under these conditions, the dot pattern achieved the highest rate of accurate responses.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Optometry
Journal of Optometry OPHTHALMOLOGY-
CiteScore
5.20
自引率
0.00%
发文量
60
审稿时长
66 days
期刊最新文献
A retinal simulation study on the influence of spherical aberration, astigmatism and optotype on the Jackson cross cylinder test Comment on: “Mean cycloplegic refractive error in emmetropic adults: The Tehran eye study” Influence of lens thickness on the accommodative range in healthy eyes Real–world outcomes on myopia management efficacy of diverse segmented defocus optics (DSDO) and defocus incorporated multiple segments (DIMS) spectacle lenses in Chinese children: An initial 12–month prospective clinical study The correlation between relative peripheral refraction and myopia progression: A commentary on the utility of retinoscopy for peripheral refraction assessment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1