Development of real-scale transformer fire test technology and evaluation of a solid aerosol-based fire suppression system

IF 3.4 3区 工程技术 Q2 ENGINEERING, CIVIL Fire Safety Journal Pub Date : 2025-03-12 DOI:10.1016/j.firesaf.2025.104376
Jong-Geon Lee , Hyun-Ho Choi
{"title":"Development of real-scale transformer fire test technology and evaluation of a solid aerosol-based fire suppression system","authors":"Jong-Geon Lee ,&nbsp;Hyun-Ho Choi","doi":"10.1016/j.firesaf.2025.104376","DOIUrl":null,"url":null,"abstract":"<div><div>Transformer fires pose significant risks to both infrastructure and human safety, and various technologies have been researched to mitigate these hazards. However, research on real-scale transformer fires remains limited due to a lack of failure data and the complexity of accurately simulating such fires. In this study, real-scale transformer fire simulation technology was further developed, and solid aerosol-based fire suppression systems were evaluated. The analysis included identifying the sources of transformer fires, studying their propagation patterns, and categorizing fire types. A testbed was constructed to simulate various fire conditions using the investigation results and a real-scale 154 kV transformer. The testbed was designed to simulate different types of transformer fires, including bushing, top, bottom, and wall fires, closely imposing real-case scenarios. Utilizing the constructed facility, fire scenarios caused by bushing insulation breakdowns were simulated, and the size of the fire source was analyzed to replicate actual fire conditions as accurately as possible. Additionally, the performance of the environmentally friendly and efficient solid aerosol-based fire suppression system was evaluated. The results demonstrated that, unlike conventional fire suppression methods, the solid aerosol system could effectively suppress transformer fires in partially opened environment with 3.2 % of opening ratio, successfully extinguishing the fire within approximately 2 min after ignition.</div></div>","PeriodicalId":50445,"journal":{"name":"Fire Safety Journal","volume":"153 ","pages":"Article 104376"},"PeriodicalIF":3.4000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0379711225000402","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

Transformer fires pose significant risks to both infrastructure and human safety, and various technologies have been researched to mitigate these hazards. However, research on real-scale transformer fires remains limited due to a lack of failure data and the complexity of accurately simulating such fires. In this study, real-scale transformer fire simulation technology was further developed, and solid aerosol-based fire suppression systems were evaluated. The analysis included identifying the sources of transformer fires, studying their propagation patterns, and categorizing fire types. A testbed was constructed to simulate various fire conditions using the investigation results and a real-scale 154 kV transformer. The testbed was designed to simulate different types of transformer fires, including bushing, top, bottom, and wall fires, closely imposing real-case scenarios. Utilizing the constructed facility, fire scenarios caused by bushing insulation breakdowns were simulated, and the size of the fire source was analyzed to replicate actual fire conditions as accurately as possible. Additionally, the performance of the environmentally friendly and efficient solid aerosol-based fire suppression system was evaluated. The results demonstrated that, unlike conventional fire suppression methods, the solid aerosol system could effectively suppress transformer fires in partially opened environment with 3.2 % of opening ratio, successfully extinguishing the fire within approximately 2 min after ignition.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Fire Safety Journal
Fire Safety Journal 工程技术-材料科学:综合
CiteScore
5.70
自引率
9.70%
发文量
153
审稿时长
60 days
期刊介绍: Fire Safety Journal is the leading publication dealing with all aspects of fire safety engineering. Its scope is purposefully wide, as it is deemed important to encourage papers from all sources within this multidisciplinary subject, thus providing a forum for its further development as a distinct engineering discipline. This is an essential step towards gaining a status equal to that enjoyed by the other engineering disciplines.
期刊最新文献
Development of real-scale transformer fire test technology and evaluation of a solid aerosol-based fire suppression system Editorial Board Charring design model for light timber frame assemblies with load-bearing I-joists Fire response of steel frames retrofitted against progressive collapse Characteristics of triacetone triperoxide (TATP) formed in 2-propanol
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1