{"title":"Fast In-Phantom Absorbed Power Density Evaluation at mmWaves Based on Infrared Measurements","authors":"Massinissa Ziane;Artem Boriskin;Maxim Zhadobov","doi":"10.1109/JMW.2025.3539871","DOIUrl":null,"url":null,"abstract":"This article introduces a novel method for fast measurement of the absorbed power density (APD) induced by an electromagnetic field (EMF) emmitting device operating near the human body at frequencies above 6 GHz, taking into account antenna/body interaction. The method employs an infrared (IR) thermography to remotely monitor the heat induced in a reflectivity-based skin equivalent phantom designed to reproduce the EMF scattering properties of human skin and the APD inside the human body. Such a phantom, implemented in the form of a thin planar solid dielectric structure, perturbs the device under test in a similar way as it would be perturbed by the presence of the human body, allowing the absorbed microwave energy to be effectively converted into an IR signal. The heat dynamics and the spatial temperature distribution on the phantom surface are measured by an IR camera and then converted to APD by postprocessing. To enhance the sensitivity of the method and to minimize the effect of heat conduction, spectral filtering is used. The proposed method is validated at 60 GHz using reference antennas (i.e. a cavity-fed dipole array and a pyramidal horn loaded with a slot array). The measured APD is compared with the reference APD simulated in human skin. The high accuracy and significant measurement time reduction, compared to conventional RF-based APD evaluation techniques, demonstrate a promising potential of the proposed IR-based method for fast EMF dosimetry and user exposure compliance testing of millimeter-wave (mmWave) 5 G and 6 G wireless devices.","PeriodicalId":93296,"journal":{"name":"IEEE journal of microwaves","volume":"5 2","pages":"269-280"},"PeriodicalIF":6.9000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10930962","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE journal of microwaves","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10930962/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This article introduces a novel method for fast measurement of the absorbed power density (APD) induced by an electromagnetic field (EMF) emmitting device operating near the human body at frequencies above 6 GHz, taking into account antenna/body interaction. The method employs an infrared (IR) thermography to remotely monitor the heat induced in a reflectivity-based skin equivalent phantom designed to reproduce the EMF scattering properties of human skin and the APD inside the human body. Such a phantom, implemented in the form of a thin planar solid dielectric structure, perturbs the device under test in a similar way as it would be perturbed by the presence of the human body, allowing the absorbed microwave energy to be effectively converted into an IR signal. The heat dynamics and the spatial temperature distribution on the phantom surface are measured by an IR camera and then converted to APD by postprocessing. To enhance the sensitivity of the method and to minimize the effect of heat conduction, spectral filtering is used. The proposed method is validated at 60 GHz using reference antennas (i.e. a cavity-fed dipole array and a pyramidal horn loaded with a slot array). The measured APD is compared with the reference APD simulated in human skin. The high accuracy and significant measurement time reduction, compared to conventional RF-based APD evaluation techniques, demonstrate a promising potential of the proposed IR-based method for fast EMF dosimetry and user exposure compliance testing of millimeter-wave (mmWave) 5 G and 6 G wireless devices.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
10.70
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
Front Cover Table of Contents IEEE Journal of Microwaves Table of Contents Depth Camera Motion Tracking for Motion Compensation and ISAR Imaging in Walk-Through Security Scanners Fast In-Phantom Absorbed Power Density Evaluation at mmWaves Based on Infrared Measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1