{"title":"Application of Pseudo-enhancement Correction to Virtual Monochromatic CT Colonography.","authors":"Rie Tachibana, Janne J Näppi, Hiroyuki Yoshida","doi":"10.1007/978-3-319-13692-9_16","DOIUrl":null,"url":null,"abstract":"<p><p>In CT colonography, orally administered positive-contrast fecal-tagging agents are used for differentiating residual fluid and feces from true lesions. However, the presence of high-density tagging agent in the colon can introduce erroneous artifacts, such as local pseudo-enhancement and beam-hardening, on the reconstructed CT images, thereby complicating reliable detection of soft-tissue lesions. In dual-energy CT colonography, such image artifacts can be reduced by the calculation of virtual monochromatic CT images, which provide more accurate quantitative attenuation measurements than conventional single-energy CT colonography. In practice, however, virtual monochromatic images may still contain some pseudo-enhancement artifacts, and efforts to minimize radiation dose may enhance such artifacts. In this study, we evaluated the effect of image-based pseudo-enhancement post-correction on virtual monochromatic images in standard-dose and low-dose dual-energy CT colonography. The mean CT values of the virtual monochromatic standard-dose CT images of 51 polyps and those of the virtual monochromatic low-dose CT images of 20 polyps were measured without and with the pseudo-enhancement correction. Statistically significant differences were observed between uncorrected and pseudo-enhancement-corrected images of polyps covered by fecal tagging in standard-dose CT (p < 0.001) and in low-dose CT (p < 0.05). The results indicate that image-based pseudo-enhancement post-correction can be useful for optimizing the performance of image-processing applications in virtual monochromatic CT colonography.</p>","PeriodicalId":91045,"journal":{"name":"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)","volume":"8676 ","pages":"169-178"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4521398/pdf/nihms671806.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/978-3-319-13692-9_16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In CT colonography, orally administered positive-contrast fecal-tagging agents are used for differentiating residual fluid and feces from true lesions. However, the presence of high-density tagging agent in the colon can introduce erroneous artifacts, such as local pseudo-enhancement and beam-hardening, on the reconstructed CT images, thereby complicating reliable detection of soft-tissue lesions. In dual-energy CT colonography, such image artifacts can be reduced by the calculation of virtual monochromatic CT images, which provide more accurate quantitative attenuation measurements than conventional single-energy CT colonography. In practice, however, virtual monochromatic images may still contain some pseudo-enhancement artifacts, and efforts to minimize radiation dose may enhance such artifacts. In this study, we evaluated the effect of image-based pseudo-enhancement post-correction on virtual monochromatic images in standard-dose and low-dose dual-energy CT colonography. The mean CT values of the virtual monochromatic standard-dose CT images of 51 polyps and those of the virtual monochromatic low-dose CT images of 20 polyps were measured without and with the pseudo-enhancement correction. Statistically significant differences were observed between uncorrected and pseudo-enhancement-corrected images of polyps covered by fecal tagging in standard-dose CT (p < 0.001) and in low-dose CT (p < 0.05). The results indicate that image-based pseudo-enhancement post-correction can be useful for optimizing the performance of image-processing applications in virtual monochromatic CT colonography.