Elastic Deformation of Optical Coherence Tomography Images of Diabetic Macular Edema for Deep-Learning Models Training: How Far to Go?

IF 3.7 3区 医学 Q2 ENGINEERING, BIOMEDICAL IEEE Journal of Translational Engineering in Health and Medicine-Jtehm Pub Date : 2023-07-24 DOI:10.1109/JTEHM.2023.3294904
Daniel Bar-David;Laura Bar-David;Yinon Shapira;Rina Leibu;Dalia Dori;Aseel Gebara;Ronit Schneor;Anath Fischer;Shiri Soudry
{"title":"Elastic Deformation of Optical Coherence Tomography Images of Diabetic Macular Edema for Deep-Learning Models Training: How Far to Go?","authors":"Daniel Bar-David;Laura Bar-David;Yinon Shapira;Rina Leibu;Dalia Dori;Aseel Gebara;Ronit Schneor;Anath Fischer;Shiri Soudry","doi":"10.1109/JTEHM.2023.3294904","DOIUrl":null,"url":null,"abstract":"– Objective: To explore the clinical validity of elastic deformation of optical coherence tomography (OCT) images for data augmentation in the development of deep-learning model for detection of diabetic macular edema (DME). Methods: Prospective evaluation of OCT images of DME (n = 320) subject to elastic transformation, with the deformation intensity represented by (\n<inline-formula> <tex-math>$\\sigma$ </tex-math></inline-formula>\n). Three sets of images, each comprising 100 pairs of scans (100 original & 100 modified), were grouped according to the range of (\n<inline-formula> <tex-math>$\\sigma$ </tex-math></inline-formula>\n), including low-, medium- and high-degree of augmentation; (\n<inline-formula> <tex-math>$\\sigma $ </tex-math></inline-formula>\n = 1-6), (\n<inline-formula> <tex-math>$\\sigma $ </tex-math></inline-formula>\n = 7-12), and (\n<inline-formula> <tex-math>$\\sigma $ </tex-math></inline-formula>\n = 13-18), respectively. Three retina specialists evaluated all datasets in a blinded manner and designated each image as ’original‘ versus ’modified‘. The rate of assignment of ’original‘ value to modified images (false-negative) was determined for each grader in each dataset. Results: The false-negative rates ranged between 71-77% for the low-, 63-76% for the medium-, and 50-75% for the high-augmentation categories. The corresponding rates of correct identification of original images ranged between 75-85% (\n<inline-formula> <tex-math>$\\text{p}&gt;$ </tex-math></inline-formula>\n0.05) in the low-, 73-85% (\n<inline-formula> <tex-math>$\\text{p}&gt;$ </tex-math></inline-formula>\n0.05 for graders 1 & 2, p = 0.01 for grader 3) in the medium-, and 81-91% (\n<inline-formula> <tex-math>$\\text{p} &lt; 0.005$ </tex-math></inline-formula>\n) in the high-augmentation categories. In the subcategory (\n<inline-formula> <tex-math>$\\sigma $ </tex-math></inline-formula>\n = 7-9) the false-negative rates were 93-83%, whereas the rates of correctly identifying original images ranged between 89-99% (\n<inline-formula> <tex-math>$\\text{p}&gt;$ </tex-math></inline-formula>\n0.05 for all graders). Conclusions: Deformation of low-medium intensity (\n<inline-formula> <tex-math>$\\sigma $ </tex-math></inline-formula>\n = 1-9) may be applied without compromising OCT image representativeness in DME. Clinical and Translational Impact Statement—Elastic deformation may efficiently augment the size, robustness, and diversity of training datasets without altering their clinical value, enhancing the development of high-accuracy algorithms for automated interpretation of OCT images.","PeriodicalId":54255,"journal":{"name":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","volume":"11 ","pages":"487-494"},"PeriodicalIF":3.7000,"publicationDate":"2023-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/3f/b0/jtehm-bardavid-3294904.PMC10561735.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10192390/","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

Abstract

– Objective: To explore the clinical validity of elastic deformation of optical coherence tomography (OCT) images for data augmentation in the development of deep-learning model for detection of diabetic macular edema (DME). Methods: Prospective evaluation of OCT images of DME (n = 320) subject to elastic transformation, with the deformation intensity represented by ( $\sigma$ ). Three sets of images, each comprising 100 pairs of scans (100 original & 100 modified), were grouped according to the range of ( $\sigma$ ), including low-, medium- and high-degree of augmentation; ( $\sigma $ = 1-6), ( $\sigma $ = 7-12), and ( $\sigma $ = 13-18), respectively. Three retina specialists evaluated all datasets in a blinded manner and designated each image as ’original‘ versus ’modified‘. The rate of assignment of ’original‘ value to modified images (false-negative) was determined for each grader in each dataset. Results: The false-negative rates ranged between 71-77% for the low-, 63-76% for the medium-, and 50-75% for the high-augmentation categories. The corresponding rates of correct identification of original images ranged between 75-85% ( $\text{p}>$ 0.05) in the low-, 73-85% ( $\text{p}>$ 0.05 for graders 1 & 2, p = 0.01 for grader 3) in the medium-, and 81-91% ( $\text{p} < 0.005$ ) in the high-augmentation categories. In the subcategory ( $\sigma $ = 7-9) the false-negative rates were 93-83%, whereas the rates of correctly identifying original images ranged between 89-99% ( $\text{p}>$ 0.05 for all graders). Conclusions: Deformation of low-medium intensity ( $\sigma $ = 1-9) may be applied without compromising OCT image representativeness in DME. Clinical and Translational Impact Statement—Elastic deformation may efficiently augment the size, robustness, and diversity of training datasets without altering their clinical value, enhancing the development of high-accuracy algorithms for automated interpretation of OCT images.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于深度学习模型训练的糖尿病黄斑水肿光学相干断层扫描图像的弹性变形:还有多远?
-目的:探讨光学相干断层扫描(OCT)图像弹性变形用于数据增强的临床有效性,以开发检测糖尿病黄斑水肿(DME)的深度学习模型。方法:前瞻性评估经过弹性转换的DME(n=320)的OCT图像,变形强度用([公式:见正文])表示。三组图像,每组包括100对扫描(100个原始和100个修改),根据([公式:见正文])的范围进行分组,包括低、中和高增强度;([公式:见正文]=1-6)、([公式,见正文]=7-12)和([公式;见正文]=13-18)。三位视网膜专家以盲法评估了所有数据集,并将每张图像指定为“原始”和“修改”。为每个数据集中的每个分级器确定修改图像的“原始”值分配率(假阴性)。结果:低扩增类别的假阴性率在71-77%之间,中扩增类别为63-76%,高扩增类别为50-75%。原始图像的相应正确识别率在低级别的75-85%([公式:见正文]0.05)、中等级别的73-85%([公式,见正文]0.05%,3级的p=0.01)和高增强级别的81-91%([公式;见正文])之间。在子类别([公式:见正文]=7-9)中,假阴性率为93-83%,而正确识别原始图像的比率在89-99%之间(所有分级器的[公式:参见正文]0.05)。临床和转化影响声明弹性变形可以有效地增加训练数据集的大小、稳健性和多样性,而不会改变其临床价值,从而促进OCT图像自动解释的高精度算法的开发。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.40
自引率
2.90%
发文量
65
审稿时长
27 weeks
期刊介绍: The IEEE Journal of Translational Engineering in Health and Medicine is an open access product that bridges the engineering and clinical worlds, focusing on detailed descriptions of advanced technical solutions to a clinical need along with clinical results and healthcare relevance. The journal provides a platform for state-of-the-art technology directions in the interdisciplinary field of biomedical engineering, embracing engineering, life sciences and medicine. A unique aspect of the journal is its ability to foster a collaboration between physicians and engineers for presenting broad and compelling real world technological and engineering solutions that can be implemented in the interest of improving quality of patient care and treatment outcomes, thereby reducing costs and improving efficiency. The journal provides an active forum for clinical research and relevant state-of the-art technology for members of all the IEEE societies that have an interest in biomedical engineering as well as reaching out directly to physicians and the medical community through the American Medical Association (AMA) and other clinical societies. The scope of the journal includes, but is not limited, to topics on: Medical devices, healthcare delivery systems, global healthcare initiatives, and ICT based services; Technological relevance to healthcare cost reduction; Technology affecting healthcare management, decision-making, and policy; Advanced technical work that is applied to solving specific clinical needs.
期刊最新文献
A Multi-Task Based Deep Learning Framework With Landmark Detection for MRI Couinaud Segmentation Video-Based Respiratory Rate Estimation for Infants in the NICU A Novel Chest-Based PPG Measurement System Integrating Multimodal Neuroimaging and Genetics: A Structurally-Linked Sparse Canonical Correlation Analysis Approach A Pre-Voiding Alarm System Using Wearable Ultrasound and Machine Learning Algorithms for Children With Nocturnal Enuresis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1