A silver nanowire-based flexible pressure sensor to measure the non-nutritive sucking power of neonates

IF 4.7 Q2 NANOSCIENCE & NANOTECHNOLOGY Micro and Nano Systems Letters Pub Date : 2020-10-07 DOI:10.1186/s40486-020-00121-0
Jean G. de Oliveira, Tausif Muhammad, Sohee Kim
{"title":"A silver nanowire-based flexible pressure sensor to measure the non-nutritive sucking power of neonates","authors":"Jean G. de Oliveira,&nbsp;Tausif Muhammad,&nbsp;Sohee Kim","doi":"10.1186/s40486-020-00121-0","DOIUrl":null,"url":null,"abstract":"<p>Preterm infants are prone to have higher risks of morbidity, disability and developmental delay compared to term infants. The primitive reflexes, inborn behaviors found in early life development, are shown to be a good tool to assess the integrity of the central nervous system of infants and to predict potential malfunctions. Among these reflexes, the non-nutritive sucking reflex plays an important role in indicating congenital abnormalities in brain development and feeding readiness, especially for premature infants. Conventionally, pediatricians evaluate the oral sucking power qualitatively based on their experiences, by using a gloved finger put inside the infant’s mouth. Thus, more quantitative solutions to assess the sucking power of preterm infants are necessary to support healthcare professionals in their evaluation procedures. Here, we developed a silver nanowire (AgNW)-based flexible pressure sensor to measure the non-nutritive sucking power of infants. The flexible sensor was fabricated using silver nanowires deposited on polydimethylsiloxane (PDMS) in a sandwich-like structure. The sensor based on the principle of strain gauge was attached to a ring-shaped connecting module, and then to a pacifier. The negative sucking pressure exerted by the infant deformed the sensor membrane, causing its electrical resistance to change without any contact between the infant’s mouth and the sensing element. The fabricated sensor was characterized and optimized to achieve both the suitable sensitivity and stability. Thanks to the excellent long-term electro-mechanical stability and high sensitivity, the developed sensor is expected to provide the means to quantitatively assess the non-nutritive sucking of infants, with a portable, low-cost, non-invasive and light-weight solution.</p>","PeriodicalId":704,"journal":{"name":"Micro and Nano Systems Letters","volume":"8 1","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2020-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s40486-020-00121-0","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micro and Nano Systems Letters","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s40486-020-00121-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NANOSCIENCE & NANOTECHNOLOGY","Score":null,"Total":0}
引用次数: 5

Abstract

Preterm infants are prone to have higher risks of morbidity, disability and developmental delay compared to term infants. The primitive reflexes, inborn behaviors found in early life development, are shown to be a good tool to assess the integrity of the central nervous system of infants and to predict potential malfunctions. Among these reflexes, the non-nutritive sucking reflex plays an important role in indicating congenital abnormalities in brain development and feeding readiness, especially for premature infants. Conventionally, pediatricians evaluate the oral sucking power qualitatively based on their experiences, by using a gloved finger put inside the infant’s mouth. Thus, more quantitative solutions to assess the sucking power of preterm infants are necessary to support healthcare professionals in their evaluation procedures. Here, we developed a silver nanowire (AgNW)-based flexible pressure sensor to measure the non-nutritive sucking power of infants. The flexible sensor was fabricated using silver nanowires deposited on polydimethylsiloxane (PDMS) in a sandwich-like structure. The sensor based on the principle of strain gauge was attached to a ring-shaped connecting module, and then to a pacifier. The negative sucking pressure exerted by the infant deformed the sensor membrane, causing its electrical resistance to change without any contact between the infant’s mouth and the sensing element. The fabricated sensor was characterized and optimized to achieve both the suitable sensitivity and stability. Thanks to the excellent long-term electro-mechanical stability and high sensitivity, the developed sensor is expected to provide the means to quantitatively assess the non-nutritive sucking of infants, with a portable, low-cost, non-invasive and light-weight solution.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种基于银纳米线的柔性压力传感器,用于测量新生儿非营养性吸吮力
与足月婴儿相比,早产儿有更高的发病、残疾和发育迟缓的风险。原始反射是早期生命发育中发现的先天行为,是评估婴儿中枢神经系统完整性和预测潜在功能障碍的良好工具。在这些反射中,非营养性吸吮反射在指示大脑发育和喂养准备的先天性异常中起着重要作用,特别是对于早产儿。传统上,儿科医生根据他们的经验,用戴着手套的手指放进婴儿的嘴里,定性地评估口腔吸吮力。因此,更多的定量解决方案来评估早产儿的吸吮力是必要的,以支持医疗保健专业人员在他们的评估程序。在这里,我们开发了一种基于银纳米线(AgNW)的柔性压力传感器来测量婴儿的非营养性吸吮力。该柔性传感器采用银纳米线沉积在聚二甲基硅氧烷(PDMS)上,形成三明治状结构。基于应变计原理的传感器连接在环形连接模块上,然后连接在安抚奶嘴上。婴儿施加的负吸吮压力使传感器膜变形,使其电阻发生变化,而婴儿的嘴与传感元件之间没有任何接触。对所制备的传感器进行了表征和优化,以达到合适的灵敏度和稳定性。由于其优异的长期机电稳定性和高灵敏度,该传感器有望为定量评估婴儿非营养性吸吮提供一种便携式、低成本、无创和轻量化的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Micro and Nano Systems Letters
Micro and Nano Systems Letters Engineering-Biomedical Engineering
CiteScore
10.60
自引率
5.60%
发文量
16
审稿时长
13 weeks
期刊最新文献
ZnO-adipic acid composites as phase change material for latent heat thermal energy storage systems Behavior of 1-octanol and biphasic 1-octanol/water droplets in a digital microfluidic system Investigating non fluorescence nanoparticle transport in Matrigel-filled microfluidic devices using synchrotron X-ray scattering Flexible sensing probe for the simultaneous monitoring of neurotransmitters imbalance Effect of pure (ligand-free) nanoparticles of magnetite in sodium chloride matrix on hematological indicators, blood gases, electrolytes and serum iron
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1