A Torsion Relative Angle Measurement Method Based on Fiber-Loop Ring-Down with Intra-Cavity Amplification

Q3 Engineering Micro and Nanosystems Pub Date : 2021-06-08 DOI:10.2174/1876402913666210608162229
Tao Ma, Yongsheng Tian, Shaohui Liu, Jiahe Ma, Heng Liu, Fang Wang, Ziqiang Zhou
{"title":"A Torsion Relative Angle Measurement Method Based on Fiber-Loop Ring-Down with Intra-Cavity Amplification","authors":"Tao Ma, Yongsheng Tian, Shaohui Liu, Jiahe Ma, Heng Liu, Fang Wang, Ziqiang Zhou","doi":"10.2174/1876402913666210608162229","DOIUrl":null,"url":null,"abstract":"\n\nThe fiber-loop ring-down spectroscopy technique has the benefits of optical fiber sensors and also has many unique advantages. Combined with various sensor structures, the FLRD system can achieve different physical, chemical, and biological sensors.\n\n\n\nTo find a way to solve the problems of light fluctuation and low sensitivity, a high sensitivity and reliability torsion relative angle measurement system is necessary. \n\n\n\nThe torsion relative angle measurement is achieved by using the fiber loop ring-down intra-cavity amplification. The sensitivity, correlation coefficient, and repeatability are analyzed with the experiment.\n\n\n\n The sensitivity and correlation coefficient of the proposed system are 4.05 μs/° and 0.9996, respectively. The repeated experiments show that the standard deviation is 9.592×10-4.\n\n\n\nThe proposed measurement method provides a way to solve the problems of light fluctuation and low sensitivity and has promising applications in the optically active solutions, fiber radial stress birefringence, and polarization state measurement of fiber lasers.\n","PeriodicalId":18543,"journal":{"name":"Micro and Nanosystems","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micro and Nanosystems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1876402913666210608162229","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

The fiber-loop ring-down spectroscopy technique has the benefits of optical fiber sensors and also has many unique advantages. Combined with various sensor structures, the FLRD system can achieve different physical, chemical, and biological sensors. To find a way to solve the problems of light fluctuation and low sensitivity, a high sensitivity and reliability torsion relative angle measurement system is necessary. The torsion relative angle measurement is achieved by using the fiber loop ring-down intra-cavity amplification. The sensitivity, correlation coefficient, and repeatability are analyzed with the experiment. The sensitivity and correlation coefficient of the proposed system are 4.05 μs/° and 0.9996, respectively. The repeated experiments show that the standard deviation is 9.592×10-4. The proposed measurement method provides a way to solve the problems of light fluctuation and low sensitivity and has promising applications in the optically active solutions, fiber radial stress birefringence, and polarization state measurement of fiber lasers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于腔内放大光纤环路衰荡的扭转相对角测量方法
光纤环衰荡光谱技术不仅具有光纤传感器的优点,而且具有许多独特的优点。结合各种传感器结构,FLRD系统可以实现不同的物理、化学和生物传感器。为了解决光波动和灵敏度低的问题,需要一个高灵敏度、高可靠性的扭转相对角测量系统。扭力相对角的测量是利用光纤环衰缩腔内放大实现的。通过实验分析了该方法的灵敏度、相关系数和重复性。该系统的灵敏度为4.05 μs/°,相关系数为0.9996。反复实验表明,标准偏差为9.592×10-4。该测量方法为解决光波动和灵敏度低的问题提供了一条途径,在光有源溶液、光纤径向应力双折射和光纤激光器偏振态测量中具有广阔的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Micro and Nanosystems
Micro and Nanosystems Engineering-Building and Construction
CiteScore
1.60
自引率
0.00%
发文量
50
期刊最新文献
Release Kinetics of Sulfentrazone from Chitosan Clay Sulfentrazone Nanocomposite Polythiophene/Copper Vanadate Nanoribbons and their Electrochemical Sensing Properties for Detecting Benzoic Acid Pharmaceutical Applications and Advances with Zetasizer: An Essential Analytical Tool for Size and Zeta Potential Analysis Global RC Interconnects with ADL Buffers for Low-Power Applications Transethosomal Carrier of Curcumin for Improved Topical Delivery: Optimization, In-vitro and Stability Assessment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1