Conjugate heat transfer characteristics of a film-cooled turbine blade leading edge with staggered-oblique impinging jets

IF 1.9 3区 工程技术 Q3 ENGINEERING, MECHANICAL Journal of Turbomachinery-Transactions of the Asme Pub Date : 2023-09-07 DOI:10.1115/1.4063367
Hongye Li, Qiang Du, Qingzong Xu, Guangyao Xu, Haoyang Liu, Dawei Chen
{"title":"Conjugate heat transfer characteristics of a film-cooled turbine blade leading edge with staggered-oblique impinging jets","authors":"Hongye Li, Qiang Du, Qingzong Xu, Guangyao Xu, Haoyang Liu, Dawei Chen","doi":"10.1115/1.4063367","DOIUrl":null,"url":null,"abstract":"\n To improve the cooling performance, a novel impingement scheme is proposed to be used in a film-cooled turbine blade leading edge. Different from a normal one, the novel scheme consists of two rows of staggered impinging jets at oblique angles of ±35°, and is thus named as the staggered-oblique impingement scheme. A conjugated numerical investigation is carried out to illustrate the underlying mechanisms of the cooling performance. Three typical jet Reynolds numbers, 6000, 12000, and 18000, are studied using the validated SST k-ω turbulence model. Numerical results show a flow separation within the staggered-oblique impinging jets, which causes the discharge coefficient for the novel impingement scheme lower. Results also reveal a phenomenon difference that two symmetric vortices are induced by each normal impinging jet, while only one vortex appears on the acute angle side along with each staggered-oblique impinging jet. The flow fields of the staggered-oblique impingement scheme create a more uniform heat transfer distribution and a maximum of 23.7% higher area-averaged Nusselt number than the normal impingement scheme. The area-averaged overall cooling effectiveness for the novel scheme is higher than the normal one by a maximum of 4.8%. The uniformity and the enhancement of the overall cooling effectiveness arise from the wall jet being fully developed. The adiabatic cooling effectiveness is similar for both impingement schemes. This indicates that the improvement in overall cooling effectiveness for the staggered-oblique impingement scheme mainly arises from internal heat transfer.","PeriodicalId":49966,"journal":{"name":"Journal of Turbomachinery-Transactions of the Asme","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2023-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Turbomachinery-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4063367","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

To improve the cooling performance, a novel impingement scheme is proposed to be used in a film-cooled turbine blade leading edge. Different from a normal one, the novel scheme consists of two rows of staggered impinging jets at oblique angles of ±35°, and is thus named as the staggered-oblique impingement scheme. A conjugated numerical investigation is carried out to illustrate the underlying mechanisms of the cooling performance. Three typical jet Reynolds numbers, 6000, 12000, and 18000, are studied using the validated SST k-ω turbulence model. Numerical results show a flow separation within the staggered-oblique impinging jets, which causes the discharge coefficient for the novel impingement scheme lower. Results also reveal a phenomenon difference that two symmetric vortices are induced by each normal impinging jet, while only one vortex appears on the acute angle side along with each staggered-oblique impinging jet. The flow fields of the staggered-oblique impingement scheme create a more uniform heat transfer distribution and a maximum of 23.7% higher area-averaged Nusselt number than the normal impingement scheme. The area-averaged overall cooling effectiveness for the novel scheme is higher than the normal one by a maximum of 4.8%. The uniformity and the enhancement of the overall cooling effectiveness arise from the wall jet being fully developed. The adiabatic cooling effectiveness is similar for both impingement schemes. This indicates that the improvement in overall cooling effectiveness for the staggered-oblique impingement scheme mainly arises from internal heat transfer.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
具有交错倾斜撞击射流的膜冷却涡轮叶片前缘的共轭传热特性
为了提高冷却性能,提出了一种新的冲击方案,用于膜冷却涡轮叶片前缘。与常规方案不同,该方案由两排倾斜角度为±35°的交错撞击射流组成,因此被称为交错倾斜撞击方案。进行了共轭数值研究,以说明冷却性能的潜在机制。使用经验证的SST k-ω湍流模型研究了三个典型的射流雷诺数,即6000、12000和18000。数值结果表明,在交错倾斜撞击射流中存在流动分离,这导致新型撞击方案的流量系数较低。结果还揭示了一种现象差异,即每个正常的撞击射流都会产生两个对称的涡流,而随着每个交错的倾斜撞击射流,只有一个涡流出现在锐角侧。交错倾斜冲击方案的流场产生了更均匀的传热分布,并且与正常冲击方案相比,面积平均努塞尔数最多高23.7%。新方案的面积平均整体冷却效率比常规方案高出4.8%。均匀性和整体冷却效率的提高源于壁面射流的充分发展。两种冲击方案的绝热冷却效果相似。这表明,交错斜向冲击方案的整体冷却效率的提高主要来自内部传热。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.70
自引率
11.80%
发文量
168
审稿时长
9 months
期刊介绍: The Journal of Turbomachinery publishes archival-quality, peer-reviewed technical papers that advance the state-of-the-art of turbomachinery technology related to gas turbine engines. The broad scope of the subject matter includes the fluid dynamics, heat transfer, and aeromechanics technology associated with the design, analysis, modeling, testing, and performance of turbomachinery. Emphasis is placed on gas-path technologies associated with axial compressors, centrifugal compressors, and turbines. Topics: Aerodynamic design, analysis, and test of compressor and turbine blading; Compressor stall, surge, and operability issues; Heat transfer phenomena and film cooling design, analysis, and testing in turbines; Aeromechanical instabilities; Computational fluid dynamics (CFD) applied to turbomachinery, boundary layer development, measurement techniques, and cavity and leaking flows.
期刊最新文献
A Numerical Test Rig for Turbomachinery Flows Based on Large Eddy Simulations With a High-Order Discontinuous Galerkin Scheme - Part 3: Secondary Flow Effects UNDERSTANDING THERMAL UNSTEADINESS IN ENGINE REPRESENTATIVE FLOWS AND IMPROVED METHODOLOGIES FOR DERIVED HEAT TRANSFER CALCULATIONS USING THIN-FILM GAUGES A Numerical Test Rig for Turbomachinery Flows Based on Large Eddy Simulations With a High-Order Discontinuous Galerkin Scheme - Part 1: Sliding Interfaces and Unsteady Row Interactions Aerodynamics of a High-Speed Low-Pressure Turbine Cascade With Cavity Purge and Unsteady Wakes A Numerical Test Rig for Turbomachinery Flows Based on Large Eddy Simulations With a High-Order Discontinuous Galerkin Scheme - Part 2: Shock-Capturing and Transonic Flows
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1